Clinical Trials Logo

Clinical Trial Summary

Aims 1. To assess the correlation between absolute flow and resistance assessed by catheter-based thermodilution technique using CoroFlow®-system and myocardial blood flow (MBF) measured by positron emission tomography (PET) and the tracer [15O] labeled water ([15O]H2O) (15O-H2O PET) 2. To assess the correlation between impaired MBF measured with 15O-H2O PET and negative fractional flow reserve (FFR) and index of microvascular resistance (IMR) level. Hypothesis: In patients with angina pectoris and reduced MBF measured with 15O-H2O PET but no hemodynamic significant stenosis (FFR > 0.80), the IMR is >25 measured with continuous thermodilution indicating microcirculatory dysfunction. Methods: We include patients with angina pectoris and suspected coronary disease based on a cardiac-computerised tomography (CT) scan. Patients are then referred to an 15O-H2O PET (rest and stress) and then a diagnostic invasive coronary angiography (ICA) with physiological assessment.


Clinical Trial Description

Background Computer tomography coronary angiography (CTCA) is a purely an anatomical scan and can be insufficient in assessing the significance of a coronary stenosis. The latest European guidelines recommend that, as a supplementary study after heart CT and before invasive coronary angiography (ICA), a myocardial perfusion study is performed to avoid unnecessary invasive procedures. Several PET flow tracers are available, but 15O-H2O is considered the gold standard for quantification of regional myocardial perfusion since 15O-H2O is a freely diffusible tracer. 15O-water PET has been validated for measure perfusion in myocardium. 15O-H2O is an inert radiopharmaceutical of oxygen-15 (O-15) labelled water used as a tracer molecule with positron emission tomography (PET). Upon administration, 15O-H2O is freely diffusible and its distribution, as well as its clearance, are completely dependent on the rate of blood flow. 15O-H2O PET imaging is golden standard for measure tissue perfusion including myocardial perfusion. The PET agent 15O-H2O has a very short half-life of about 2 minutes thereby allowing for multiple, serial measurements. Two recent studies have described the diagnostic accuracy of 15O-H2O PET in comparison to coronary angiography. In both studies, 15O-H2O PET had a sensitivity of 87-95%; specificity was at least 84%. The study by Danad et al7 is the largest published series to date. A recently published single-center study compared 15O-H2O PET to imaging using 99mTc and found superior performance characteristics for the 15O-H2O PET, relative to a truth standard of ICA with fractional flow reserve (FFR). Fractional flow reserve (FFR) is defined as the maximum achievable blood flow that can still be maintained to myocardium despite the stenosis. Also described as the ratio between the pressure distal to the stenosis (Pd) and the pressure proximal (Pa) to the lesion during hyperemia. In randomized trials the benefits of FFR measurements was established by comparing FFR-guided PCI plus medical therapy with just medical therapy. This showed that patients with stable coronary artery disease will benefit from FFR-guided PCI plus medical therapy in that the risk of needing urgent revascularization will be smaller.9 Randomized trials also show that if an intermediate coronary stenosis - not functionally significant - is measured to have an FFR ≥0.75, the risk of infarction from that stenosis is less than 1 %. Therefore, these patients will not benefit from PCI.10 This makes FFR an important tool for assessing which patients could benefit from a PCI and which are better off with the best medical therapy available. However, it only describes the flow of the epicardial arteries. FFR value may be non-significant (>0.80) while the patient may still have angina. This may be due to microvascular disease. The evaluation of the microvascular status when the FFR indicates non-obstructive disease (>0.80) currently has IIa indication in the ECS guidelines. Thermodilution method with the CoroFlow® (Coroventis, Uppsala, Sweden) from which coronary flow reserve and microvascular resistance can be calculated alongside the FFR value. This gives us opportunity to study coronary microcirculatory dysfunction and is believed to be common in patients with angina and no significant disease in the epicardial arteries. However, there is a gap in evidence in terms of finding the best method to conduct quantitative assessment of the microcirculatory system independently of epicardial stenoses.13 Furthermore, the combination of coronary flow reserve and microvascular resistance measured by invasive thermodilution method (CoroFlow®-system) has not previously been compared to myocardial blood flow (MBF) measured with the golden standard 15O-H2O PET. Methods: Physiological assessment protocol The ICA is performed according to present clinical guidelines through femoral or radial ar-tery. Prior to the coronary angiography, the operator administrates 250 μg of intra-coronary nitroglycerine. Anticoagulation (5,000 IU heparin) is administrated before the measure-ment. Coronary physiological assessment is performed in all vessels (left anterior descending (LAD), right coronary artery (RCA) and the circumflex artery (CX)) with the thermodilution method measuring fractional flow reserve (FFR), coronary flow reserve (CFR) and index of microcirculatory resistance (IMR). The guidewire equipped with a pressure and temperature sensor (PressureWire X, Abbott, IL) is passed through the guiding catheter. The operator infuses saline at room temperature 3 times in rest. Hyperaemia is then induced with adenosine was infused intravenously (140 mg/kg/min, then the operator infuses saline at room temperature at hyperaemia. The Coroventis system is used as pressure measuring software. Routine checks are made to ensure that 'drift' does not occur after the recordings. Drift value of ≤ ±0.02 is accepted. Protocol 15O-H20 PET Study participants will be instructed to avoid all caffeine-containing drinks and foods such as coffee, chocolate, cola, banana and tea for at least 24 hours prior to the planned admin-istration of adenosine. Quantitative myocardial perfusion at rest and during hyperemia will be measured using 2 injections (rest & stress) of 400 MBq of 15O-H2O. After an initial scout CT scan to localize the heart, a low-dose CT for attenuation correction (CTAC) of the subsequent PET emission data is performed. Following the CTAC, the rest and stress PET scans will be performed in that order. Rest scan: A PET list mode acquisition of 4 minutes in duration should be started just before the intravenous injection of 400 MBq of 15O-H2O from a water generator (MedTrace P3 system). List mode data is reconstructed with ECG-signal to an 8-bin ECG-gated blood pool image of the first pass (0-50 seconds after injection) and a dynamic data set of 22 frames from 0-4 minutes after injection. Stress scan: Pharmacological stress is induced by infusion of adenosine intravenously at a standard rate of 140µg/kg/min. Following 2 minutes of adenosine injection, vasodilation is known to reach a steady state, a second dose of 15O-H2O (400 MBq) is injected, and a new PET scan is performed like the rest scan (list mode imaging initiated before the bolus IV injection). During both acquisitions and the stress test, heart rate and blood pressure as well as any ECG related abnormalities is monitored. Data from rest and stress 15O-H2O PET scans will be analyzed using the aQuant software. Statistics and power calculations: Student's t-test will be used for continuous variables and non-parametric test for categorical variables. The diagnostic performance of 15O-H2O PET is assessed by Bland-Altmann plot and receiver operative curves. The result quality will be assessed according to the P-value (P>0.05) significance between low and high IMR groups. With a standard deviation of 10, mean difference of 15, power of 80 % and alpha value of 0.05, n=22 patients in total are needed. To accommodate for drop outs 40 patients i.e. 20 in two groups are included. In group A will be patients with a non-significant FFR value (<0.80) and an IMR value indicating no microcirculatory dysfunction (IMR <25). In group B will be patients with a non-significant FFR value (<0.80) and an IMR value indicating microcirculatory dysfunction (IMR ≥25). Publication of results Results, positive, neutral as well as negative or inconclusive, will be published in an international cardiovascular journal without delay. Publication and author issues are decided by the steering committee on basis of general involvement in the study (drafting of protocol, core lab. function, end point committee membership, etc.) and of number of included patients. The funding companies have no influence on study design, study conduct, analysis, interpretation and reporting of derived results. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04973410
Study type Interventional
Source Aarhus University Hospital Skejby
Contact
Status Active, not recruiting
Phase N/A
Start date December 1, 2019
Completion date December 31, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Coronary De Novo Lesions N/A