Coronary Artery Disease Clinical Trial
— OPCOfficial title:
A Prospective, Multicenter Trial Program in China to Evaluate the Efficacy and Safety of BuMA Supreme (eG Grafting) Biodegradable Polymer Sirolimus Eluting Stent in Patients With de Novo Coronary Lesions, OPC Trial
| Verified date | April 2024 |
| Source | Sino Medical Sciences Technology Inc. |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Interventional |
PIONEER-II OPC trial is a prospective, multicenter, single-arm registry trial. 1000 subjects from approximately 40 interventional cardiology centers will be enrolled to evaluate the target lesion failure(TLF) as the primary endpoint at 1 year. And all the subjects will be followed up to 5 years to attain the data of the secondary endpoints.
| Status | Active, not recruiting |
| Enrollment | 1000 |
| Est. completion date | December 2025 |
| Est. primary completion date | May 2019 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 18 Years to 75 Years |
| Eligibility | Inclusion Criteria: 1. Age 18-75, male or non-pregnant female 2. Evidence of non-symptomatic ischemia, stable or non-stable angina pectoris or past MI 3. Target lesion is primary and de-novo coronary artery disease 4. The target lesion length = 60 mm, diameter 2.25mm-5.0mm (visually estimated) 5. Lesion diameter stenosis =70% (visually estimated) 6. For each target lesion, same stent implantation only 7. Acceptable candidate for Coronary Artery Bypass Grafting(CABG) 8. Understand the study purpose, willing to participate and sign the letter of consent, agrees to the follow-up visits including a 9 month angiographic follow-up Exclusion Criteria: 1. Acute MI within 1 week 2. Chronic total occlusion(TIMI 0), left main lesion, intervention-required three-vessel lesions, branch vessel diameter = 2.5mm and bypass lesion 3. More than 3 stents required 4. Patients refuse to be implanted stent 5. Calcified lesion failed in pre-dilation, twisted lesion and lesion unsuitable for stent delivery and expansion 6. In-stent restenosis 7. Planned percutaneous coronary intervention (PCI) within 3 months post procedure 8. Other stents implanted within 1 year 9. Severe heart failure (NYHA above III) or left ventricle ejection fraction(EF) <40% 10. Renal function damage, blood creatinine > 176.82 µmol/L 11. Bleeding tendency, active peptic ulcer disease, cerebral or subarachnoid hemorrhage, cerebral apoplexy within half year and contraindication for any anti-platelet or anticoagulation agents 12. Allergic to drugs or agents used in stent or protocol (PLGA, sirolimus, aspirin, clopidogrel, contrast agent, cobalt, nickel, chromium, iron, wolfram et. al.) 13. Life expectation < 12 months 14. Have not reached the primary end point when participating in other trial 15. Poor compliance to the protocol 16. Heart implantation cases |
| Country | Name | City | State |
|---|---|---|---|
| China | Zhongshan Hospital | Shanghai |
| Lead Sponsor | Collaborator |
|---|---|
| Sino Medical Sciences Technology Inc. |
China,
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | Target Lesion Failure | Target Lesion Failure(TLF) is defined as cardiac death, target vessel myocardial infarction(MI), or clinically-driven target lesion revascularization (TLR). | 1 year | |
| Secondary | Stent implantation success rate | The stent implantation success rate includes device, lesion and clinical success rate. | 5 years after PCI | |
| Secondary | Device-oriented Composite Endpoint(DoCE) | Device-oriented Composite Endpoint is defined as cardiac death, target vessel MI, or clinically-driven TLR (TLF). | 1, 6, 12 month, and annually up to 5 years post procedure | |
| Secondary | Patient-oriented Composite Endpoint (PoCE) | Patient-oriented Composite Endpoint is defined as all cause death, all MI, or any revascularization. | 1, 6, 12 month, and annually up to 5 years post procedure | |
| Secondary | Academic Research Consortium(ARC) defined stent thrombosis | Definite and probable stent thrombosis during acute, subacute, later and very late phase. | 5 years after PCI |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT06030596 -
SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
|
||
| Completed |
NCT04080700 -
Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
|
||
| Recruiting |
NCT03810599 -
Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study
|
N/A | |
| Recruiting |
NCT06002932 -
Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions.
|
N/A | |
| Not yet recruiting |
NCT06032572 -
Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE)
|
N/A | |
| Recruiting |
NCT04242134 -
Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions
|
N/A | |
| Recruiting |
NCT05308719 -
Nasal Oxygen Therapy After Cardiac Surgery
|
N/A | |
| Completed |
NCT04556994 -
Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients.
|
N/A | |
| Recruiting |
NCT05846893 -
Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease
|
N/A | |
| Recruiting |
NCT06027788 -
CTSN Embolic Protection Trial
|
N/A | |
| Recruiting |
NCT05023629 -
STunning After Balloon Occlusion
|
N/A | |
| Completed |
NCT04941560 -
Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
|
||
| Completed |
NCT04006288 -
Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease
|
Phase 4 | |
| Completed |
NCT01860274 -
Meshed Vein Graft Patency Trial - VEST
|
N/A | |
| Recruiting |
NCT06174090 -
The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients
|
N/A | |
| Terminated |
NCT03959072 -
Cardiac Cath Lab Staff Radiation Exposure
|
||
| Completed |
NCT03968809 -
Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
|
||
| Recruiting |
NCT04566497 -
Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up.
|
N/A | |
| Recruiting |
NCT05065073 -
Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography
|
Phase 4 | |
| Completed |
NCT05096442 -
Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions
|
N/A |