Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02486315
Other study ID # NCTC005
Secondary ID
Status Completed
Phase
First received
Last updated
Start date April 2012
Est. completion date June 2015

Study information

Verified date March 2024
Source Clinica Mediterranea
Contact n/a
Is FDA regulated No
Health authority
Study type Observational [Patient Registry]

Clinical Trial Summary

The Axxess™ Biolimus A9™ Eluting Coronary Bifurcation Stent System (AXXESS System; Biosensors, International, Morges, Switzerland) is a dedicated bifurcation stent, designed to cover the lesion at the level of the carina. Although deemed ideal for lesions involving only the proximal MV (1,0,0 according to Medina classification ref), this device may be used also in more complex bifurcation lesions when additional DES are required in the distal MV and/or in the SB. In the present registry the investigators report the performance and the efficacy of the self-expanding biolimus-eluting AxxessTM stent for the treatment of bifurcation lesions in a real-world population.


Description:

Despite a comprehensive understanding of the physiological and technical issues regarding the coronary bifurcations lesions, percutaneous coronary intervention (PCI) in this setting remains challenging. When compared with non-bifurcation lesions, treatment of bifurcation lesions is associated with increased adverse clinical events and inferior angiographic outcomes including procedural complications. This is due to several technical challenges, including both anatomical (proximal-to-distal vessel mismatch [tapering], angulation and calcification) and procedural (plaque shift, and side-branch [SB] closure) features. Current balloon-expandable drug-eluting stent (DES) have not been designed to treat the bifurcation lesions; in particular, the inability of DES to adequately scaffold and preserve the ostium of SB represents a the major reason of failure, because this is the most common site for restenosis. Recently a large variety of dedicated bifurcation stents have been developed in order to 1) provide an easier access to the SB and to scaffold more effectively its ostium, and 2) adapt to main vassel (MV) tapering, and to the bifurcation anatomy.


Recruitment information / eligibility

Status Completed
Enrollment 326
Est. completion date June 2015
Est. primary completion date August 2014
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: 1. significant (=70% diameter stenosis) bifurcation lesion; 2. MV reference diameter between 2.75 and 4.75 mm by visually estimated 3. SB reference diameter =2.25 mm by visual estimate; 4. bifurcation angle (between the distal MV and the SB) <70° by visual estimate Exclusion Criteria: 1. patients with contraindications to prolonged dual-antiplatelet therapy, 2. known sensitivity to "limus" compounds, stainless steel, titanium, or nickel; 3. inclusion in others studies on bifurcation lesions; and 4. all bifurcation lesions not satisfying the angiographic inclusion criteria reported above

Study Design


Related Conditions & MeSH terms


Intervention

Device:
AXXESS stent
Axxess stent is a conically-shaped, self-expanding nitinol stent, with a 0.006-inch strut thickness, specifically designed to preserve and to match the anatomy of the bifurcation at the carina level. The stent is coated with Biolimus A9™, a highly lipophilic, semi-synthetic sirolimus analogue, immersed in the biodegradable polylactic acid (PLA) applied primarily to the abluminal surface. PLA completely dissolves after 6 to 9 months.The stent has 3 radiopaque markers at the distal end and one at the proximal end to aid in the visibility and placement. The AxxessTM stent is 7 Fr guiding catheter or Sheathless Guiding Catheter compatible. During the study period, the AxxessTM stent was available in 3 different diameters (3.0, 3.5 and 4.0 mm) and lengths (9, 10 and 14 mm)

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Clinica Mediterranea

References & Publications (12)

Behan MW, Holm NR, Curzen NP, Erglis A, Stables RH, de Belder AJ, Niemela M, Cooter N, Chew DP, Steigen TK, Oldroyd KG, Jensen JS, Lassen JF, Thuesen L, Hildick-Smith D. Simple or complex stenting for bifurcation coronary lesions: a patient-level pooled-analysis of the Nordic Bifurcation Study and the British Bifurcation Coronary Study. Circ Cardiovasc Interv. 2011 Feb 1;4(1):57-64. doi: 10.1161/CIRCINTERVENTIONS.110.958512. Epub 2011 Jan 4. — View Citation

Buysschaert I, Dubois CL, Dens J, Ormiston J, Worthley S, McClean D, Ottervanger JP, Meredith I, Uren N, Wijns W, Whitbourn R, Mehran R, Lansky AJ, Bichalska M, Meis S, Verheye S. Three-year clinical results of the Axxess Biolimus A9 eluting bifurcation stent system: the DIVERGE study. EuroIntervention. 2013 Sep;9(5):573-81. doi: 10.4244/EIJV9I5A93. — View Citation

Garcia E, Unzue Vallejo L, Rodriguez-Rodrigo FJ. Placement of a single Axxess stent as new treatment strategy for Medina 1,0,0 left main stem bifurcation lesion. J Invasive Cardiol. 2014 Apr;26(4):E45-7. — View Citation

Grube E, Buellesfeld L, Neumann FJ, Verheye S, Abizaid A, McClean D, Mueller R, Lansky A, Mehran R, Costa R, Gerckens U, Trauthen B, Fitzgerald PJ. Six-month clinical and angiographic results of a dedicated drug-eluting stent for the treatment of coronary bifurcation narrowings. Am J Cardiol. 2007 Jun 15;99(12):1691-7. doi: 10.1016/j.amjcard.2007.01.043. Epub 2007 May 7. — View Citation

Hasegawa T, Ako J, Koo BK, Miyazawa A, Sakurai R, Chang H, Dens J, Verheye S, Grube E, Honda Y, Fitzgerald PJ. Analysis of left main coronary artery bifurcation lesions treated with biolimus-eluting DEVAX AXXESS plus nitinol self-expanding stent: intravascular ultrasound results of the AXXENT trial. Catheter Cardiovasc Interv. 2009 Jan 1;73(1):34-41. doi: 10.1002/ccd.21765. — View Citation

Lassen JF, Holm NR, Stankovic G, Lefevre T, Chieffo A, Hildick-Smith D, Pan M, Darremont O, Albiero R, Ferenc M, Louvard Y. Percutaneous coronary intervention for coronary bifurcation disease: consensus from the first 10 years of the European Bifurcation Club meetings. EuroIntervention. 2014 Sep;10(5):545-60. doi: 10.4244/EIJV10I5A97. — View Citation

Latib A, Colombo A. Bifurcation disease: what do we know, what should we do? JACC Cardiovasc Interv. 2008 Jun;1(3):218-26. doi: 10.1016/j.jcin.2007.12.008. — View Citation

Louvard Y, Thomas M, Dzavik V, Hildick-Smith D, Galassi AR, Pan M, Burzotta F, Zelizko M, Dudek D, Ludman P, Sheiban I, Lassen JF, Darremont O, Kastrati A, Ludwig J, Iakovou I, Brunel P, Lansky A, Meerkin D, Legrand V, Medina A, Lefevre T. Classification of coronary artery bifurcation lesions and treatments: time for a consensus! Catheter Cardiovasc Interv. 2008 Feb 1;71(2):175-83. doi: 10.1002/ccd.21314. — View Citation

Medina A, Suarez de Lezo J, Pan M. [A new classification of coronary bifurcation lesions]. Rev Esp Cardiol. 2006 Feb;59(2):183. No abstract available. Spanish. — View Citation

Noguchi T, Miyazaki MD S, Morii I, Daikoku S, Goto Y, Nonogi H. Percutaneous transluminal coronary angioplasty of chronic total occlusions. Determinants of primary success and long-term clinical outcome. Catheter Cardiovasc Interv. 2000 Mar;49(3):258-64. doi: 10.1002/(sici)1522-726x(200003)49:33.0.co;2-l. — View Citation

Thygesen K, Alpert JS, Jaffe AS, Simoons ML, Chaitman BR, White HD; Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction; Katus HA, Lindahl B, Morrow DA, Clemmensen PM, Johanson P, Hod H, Underwood R, Bax JJ, Bonow RO, Pinto F, Gibbons RJ, Fox KA, Atar D, Newby LK, Galvani M, Hamm CW, Uretsky BF, Steg PG, Wijns W, Bassand JP, Menasche P, Ravkilde J, Ohman EM, Antman EM, Wallentin LC, Armstrong PW, Simoons ML, Januzzi JL, Nieminen MS, Gheorghiade M, Filippatos G, Luepker RV, Fortmann SP, Rosamond WD, Levy D, Wood D, Smith SC, Hu D, Lopez-Sendon JL, Robertson RM, Weaver D, Tendera M, Bove AA, Parkhomenko AN, Vasilieva EJ, Mendis S. Third universal definition of myocardial infarction. Circulation. 2012 Oct 16;126(16):2020-35. doi: 10.1161/CIR.0b013e31826e1058. Epub 2012 Aug 24. No abstract available. — View Citation

Wykrzykowska JJ, Grundeken MJ, Stankovic G, Di Mario C. Is there a need for dedicated devices? EuroIntervention. 2015;11 Suppl V:V139-42. doi: 10.4244/EIJV11SVA31. — View Citation

* Note: There are 12 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary device success successful deployment of the AxxessTM stent into the target lesion, without system failure or device-related complication. intraprocedural
See also
  Status Clinical Trial Phase
Recruiting NCT06030596 - SPECT Myocardial Blood Flow Quantification for Diagnosis of Ischemic Heart Disease Determined by Fraction Flow Reserve
Completed NCT04080700 - Korean Prospective Registry for Evaluating the Safety and Efficacy of Distal Radial Approach (KODRA)
Recruiting NCT03810599 - Patient-reported Outcomes in the Bergen Early Cardiac Rehabilitation Study N/A
Recruiting NCT06002932 - Comparison of PROVISIONal 1-stent Strategy With DEB Versus Planned 2-stent Strategy in Coronary Bifurcation Lesions. N/A
Not yet recruiting NCT06032572 - Evaluation of the Safety and Effectiveness of the VRS100 System in PCI (ESSENCE) N/A
Recruiting NCT04242134 - Drug-coating Balloon Angioplasties for True Coronary Bifurcation Lesions N/A
Recruiting NCT05308719 - Nasal Oxygen Therapy After Cardiac Surgery N/A
Completed NCT04556994 - Phase 1 Cardiac Rehabilitation With and Without Lower Limb Paddling Effects in Post CABG Patients. N/A
Recruiting NCT05846893 - Drug-Coated Balloon vs. Drug-Eluting Stent for Clinical Outcomes in Patients With Large Coronary Artery Disease N/A
Recruiting NCT06027788 - CTSN Embolic Protection Trial N/A
Recruiting NCT05023629 - STunning After Balloon Occlusion N/A
Completed NCT04941560 - Assessing the Association Between Multi-dimension Facial Characteristics and Coronary Artery Diseases
Completed NCT04006288 - Switching From DAPT to Dual Pathway Inhibition With Low-dose Rivaroxaban in Adjunct to Aspirin in Patients With Coronary Artery Disease Phase 4
Completed NCT01860274 - Meshed Vein Graft Patency Trial - VEST N/A
Recruiting NCT06174090 - The Effect of Video Education on Pain, Anxiety and Knowledge Levels of Coronary Bypass Graft Surgery Patients N/A
Terminated NCT03959072 - Cardiac Cath Lab Staff Radiation Exposure
Completed NCT03968809 - Role of Cardioflux in Predicting Coronary Artery Disease (CAD) Outcomes
Recruiting NCT04566497 - Assessment of Adverse Outcome in Asymptomatic Patients With Prior Coronary Revascularization Who Have a Systematic Stress Testing Strategy Or a Non-testing Strategy During Long-term Follow-up. N/A
Recruiting NCT05065073 - Iso-Osmolar vs. Low-Osmolar Contrast Agents for Optical Coherence Tomography Phase 4
Completed NCT05096442 - Compare the Safety and Efficacy of Genoss® DCB and SeQuent® Please NEO in Korean Patients With Coronary De Novo Lesions N/A