Cataract Senile Clinical Trial
Official title:
Comparative Evaluation of Long-term Axial Stability of Two Different Models of Intraocular Lenses in Patients With an Eye Length More Than 26 mm
Some parameters, such as a change in the optic tilt and axial decentration, can affect the optical characteristics of intraocular lenses (IOLs) in postoperative period, which leads to residual refractive errors and other complications. The stability of the intraocular lens in the eye is largely dependent on the mechanical design of its haptic support elements. Thus, the new Clareon IOL has a flat haptic with a flexible design that minimizes axial changes and allows the IOL to maintain a stable position in a given plane during compression. Currently there is no published data of the stability for Clareon AutonoMe IOL for long eyes. The purpose of the current study is to evaluate and compare the axis displacement and stability of optical tilt, visual and refractive results in patients after implantation of two different models of intraocular lenses: Clareon AutonoMe (Alcon, USA) and Hoya iSert 251 (Japan) in the long-term postoperative period (after cataract surgery).
The optical performance of intraocular lenses (IOLs) can be affected by changes in optic tilt and decentration that occur after implantation, resulting in residual refractive errors and other complications. Intraocular lens stability is largely dependent on the mechanical design of the haptics. Clareon IOL has a flat haptic with a flexible design that minimizes axial changes and allows the IOL to maintain a stable position in a given plane during compression. Based on our knowledge, nobody has compared Clareon AutonoMe and Hoya iSert 251 IOLs in clinical setting. Scientific Rationale: This study investigates the stability of IOLs in patients with long axial length. IOL stability on long eyes has a limited clinical data, no in Vivo research has been done. It is known that eyes with long axial length have a large capsule bag. With such eyes, it is difficult to predict the effective lens position. Each 0,5 mm axial displacement lead to approximately 0,5 D of the refractive error. For long eyes, it is important to use the latest generation of multi-component IOL calculation formulas for accurately prediction of effective lens position. The mail purpose of the study is to evaluate and compare the axis displacement and stability of optical tilt, visual and refractive results in patients after implantation of two different models of intraocular lenses: Clareon AutonoMe (Alcon, USA) and Hoya iSert 251 (Japan) in the long-term postoperative period (after cataract surgery). The research purpose is to evaluate the prediction error for each IOL calculation formula (Barrett Universal II, Kane, EVO, Holladay I with Van Koch correction) ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04998409 -
Evaluation of a Spherical Hydrophilic Acrylic Intraocular Lens
|
||
Completed |
NCT04252716 -
VISPER: Randomised Comparison of Two OVDs in Cataract Surgery
|
||
Recruiting |
NCT05110222 -
Cataract Lens Hardness Based on Phaco Tip Resistance
|
||
Recruiting |
NCT04266847 -
Prospective Clinical Study of Preoperative and Postoperative Unilateral Mild Cataract Patients
|
N/A | |
Recruiting |
NCT04175951 -
Tecnis Eyhance Versus Rayner RayOne Study
|
N/A | |
Recruiting |
NCT04572334 -
Eyhance Autorefraction Study
|
N/A | |
Completed |
NCT04140383 -
Cataract Surgery In Patients With Advanced Age
|
||
Active, not recruiting |
NCT04570579 -
Impact of a Novel Extended Depth of Focus Intraocular Lens on Visual and Lifestyle Enhancement
|
||
Completed |
NCT05347615 -
Achieving Hybrid Monovision By Paring Monofocal And EDOF Lens Technology
|
||
Recruiting |
NCT05148507 -
Optimization of the Ocular Surface Prior to Cataract Surgery Using PROKERA
|
N/A | |
Completed |
NCT04655274 -
Comparision of Visual Outcomes and Patient Satisfaction Between Two Diffractive Trifocal Intraocular Lenses
|
||
Completed |
NCT04255706 -
Repeatability in Measurements of Two ssOCT and One OLCR Biometer
|
N/A | |
Completed |
NCT05287269 -
Ocular Coherence Tomography During Cataract Assessment
|
||
Completed |
NCT04545671 -
Evaluation of a Trifocal Lens
|
||
Completed |
NCT04580550 -
Axial Length Variability
|
N/A | |
Recruiting |
NCT04265846 -
Prospective Clinical Study of Different Intraocular Lens Implantation Designed for the Correction of Presbyopia
|
||
Not yet recruiting |
NCT06429527 -
Vision Test App and Questionnaire for 1-Week Post-Cataract Surgery Follow-Up: A Multi-Center Randomized Controlled Trial
|
N/A | |
Completed |
NCT03970525 -
Venturi and Peristaltic Based Phacoemulsification in Femtosecond Laser Cataract Surgery
|
||
Completed |
NCT04333056 -
Comparison Between Two Ss-OCT Biometry
|
||
Completed |
NCT05578339 -
Predicting the Lens Capsular Bag Size Using Pre-operative Biometry
|
N/A |