Congestive Heart Failure Clinical Trial
Official title:
His Bundle Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy
The goal of this study is to compare the effectiveness of pacing from a physiologic His bundle (HB) lead position versus with the standard coronary sinus (CS) lead position in subjects with heart failure undergoing cardiac resynchronization therapy (CRT). While placement of left ventricular leads via the coronary sinus has anatomic limitations, we hypothesis that the achievement of QRS narrowing with His bundle capture will be superior for improving systolic function by echocardiographic indices (ejection fraction and strain) and quality of life and decreased rehospitalization and mortality.
This is a randomized, single-blinded study of 40 patients to a strategy of HB pacing versus CS pacing, and remain blinded to their treatment allocation. Both treatment options use standard-of-care, FDA-approved devices. The distinction is only in the allocation toward HB pacing and CS pacing. Treating physicians will be aware of assignment in order to facilitate routine device follow-up. Echocardiographic and electrocardiographic evaluation will also be performed in a blinded manner. Cross-over is permitted between treatment group allocation if: - CS lead cannot be placed due to difficult cannulation of the CS, limited branches at the posterolateral or lateral wall, or phrenic nerve capture. These subjects may then cross-over to HB pacing. - HB pacing subjects may cross-over if HB lead cannot be positioned with adequate stability and reasonable pacing output, or if QRS width does not narrow by at least 20% or to a QRS width of ≤ 130 msec. Implant procedure will be per routine percutaneous access, as is standard for pacemaker and ICDs. All subjects will receive an FDA-approved cardiac resynchronization therapy pacemaker or defibrillator device, as per standard of care outlined for the subject. In order to facilitate optimal lead placement, arterial access for levo-phase CS angiography and/or LV septal mapping to characterize site of bundle-branch block may also be performed, at the discretion of the implanting physician per his/her standard practice. Follow-up will be performed at 2 weeks post-implant for incision check and device interrogation as is standard of care. In addition, routine device and clinical follow-up will be scheduled at 1, 3, 6, and 12 months. Electrocardiography (ECG) will be performed pre-implant, prior to hospital discharge, at 3 months, 6 months, and 12 months. Echocardiography will be performed pre-implant and 6 months to evaluate for change in LVEF, chamber dimension, and wall motion with strain imaging as is standard of care in the treatment of patients with advanced heart failure. NYHA functional class and quality of life (utilizing the Kansas City Cardiomyopathy Questionnaire) will be assessed pre-implant and at 6 months. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Terminated |
NCT04115735 -
His Bundle Recording From Subclavian Vein
|
||
Recruiting |
NCT05562037 -
Stepped Care vs Center-based Cardiopulmonary Rehabilitation for Older Frail Adults Living in Rural MA
|
N/A | |
Completed |
NCT05563701 -
Evaluation of the LVivo Image Quality Scoring (IQS)
|
||
Recruiting |
NCT05865184 -
Evaluation of Home-based Sensor System to Detect Health Decompensation in Elderly Patients With History of CHF or COPD
|
||
Completed |
NCT04037436 -
Functional Exercise and Nutrition Education Program for Older Adults
|
N/A | |
Recruiting |
NCT04703842 -
Modulation of SERCA2a of Intra-myocytic Calcium Trafficking in Heart Failure With Reduced Ejection Fraction
|
Phase 1/Phase 2 | |
Terminated |
NCT05594940 -
Heart Failure Monitoring With a Portable Ultrasound Device With Artificial Intelligence Assisted Tools: A Multi-Phase Observational Feasibility Study
|
||
Recruiting |
NCT04982081 -
Treating Congestive HF With hiPSC-CMs Through Endocardial Injection
|
Phase 1 | |
Completed |
NCT04394754 -
Evaluating Efficacy of Digital Health Technology in the Treatment of Congestive Heart Failure
|
N/A | |
Active, not recruiting |
NCT01385176 -
Neural Cardiac Therapy for Heart Failure Study (NECTAR-HF)
|
N/A | |
Not yet recruiting |
NCT05516290 -
Evaluating Clinical Trial Experiences of Individuals With Congestive Heart Failure
|
||
Terminated |
NCT02788656 -
Pulmonary Artery Pressure Reduction With ENTresto (Sacubitril/Valsartan)
|
Phase 4 | |
Completed |
NCT02885636 -
Inhaled Beta-adrenergic Agonists to Treat Pulmonary Vascular Disease in Heart Failure With Preserved EF (BEAT HFpEF): A Randomized Controlled Trial
|
Phase 3 | |
Completed |
NCT02252757 -
Assess Measurements of Wireless Cardiac Output Device
|
N/A | |
Terminated |
NCT02205411 -
Clinical Trial to Evaluate the the ReliantHeart HeartAssist 5® VAD System in Patients Awaiting Heart Transplantation
|
N/A | |
Completed |
NCT01362855 -
Advance Care Planning Evaluation in Hospitalized Elderly Patients
|
||
Completed |
NCT01476995 -
Prognostic Indicators as Provided by the EPIC ClearView
|
N/A | |
Withdrawn |
NCT00346177 -
Stem Cell Study for Patients With Heart Failure
|
Phase 2 | |
Active, not recruiting |
NCT01058837 -
SCD-HeFT 10 Year Follow-up
|
N/A | |
Completed |
NCT00957541 -
Evaluation of a Diagnostic Feature in a Cardiac Resynchronization Therapy (CRT) Device
|
Phase 2 |