View clinical trials related to Congenital Hip Dysplasia.
Filter by:This study is being conducted to gather medium and long-term information regarding the performance and safety of the commercially available DURALOC® Option Ceramic-on-Ceramic Hip Prosthesis System.
The purpose of this study is to evaluate whether successful external cephalic version is associated with maternal thyroid function and mood state in pregnant women with breech presentation at term. The relationship between successful external cephalic version and neonatal thyroid function will also be investigated. A possible beneficial effect of successful external cephalic version on the development of congenital hip dysplasia will be evaluated.
This post-market clinical follow-up study was designed to compare hip replacement outcomes of the European Hip against 3 controls (Omniflex, Zweymuller, and Spotorno), however Omniflex did not end up being used. The first patient had surgery on February 18, 2000 and the final patient had surgery on September 2, 2005. There were 317 subjects consented but only 301 had hip replacement surgery (subjects received: 220 European hips, 33 Zweymuller, and 48 Spotorno). The study took place at three sites. Each site used their standard device as the control. The Austrian site enrolled 69 European hips and 33 Zweymuller hips. 92 European hips and 48 Spotorno hips were enrolled in Germany. Finally, the site in Italy enrolled 59 European hips. Although the study protocol intended collecting DEXA and RSA outcomes, the data collected by the sites did not include these outcomes.
The purpose of this study is to monitor the performance of the DePuy PROXIMA™ hip in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments. A subset of patients will undergo scans to allow the bone mineral density of the bone surrounding the implant to be monitored
The purpose of this study is to compare the performance and compare the wear characteristics of two polyethylene cup liners, Marathon™ and Enduron™, in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be randomly allocated to one of the polyethylene cup liners, Marathon™ or Enduron™ and will be evaluated at regular intervals using clinical and x-ray assessments.
The purpose of this study is to monitor the performance of the Pinnacle™ Cup with a polyethylene-on-metal bearing combination in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments.
The purpose of this study is to monitor the performance of the Summit™ hip in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments.
The purpose of this study is to monitor the performance and determine the metal ion release of the DePuy ASR™ System in the treatment of patients with hip joint disease requiring hip resurfacing surgery. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments. A subset of patients will also have blood samples taken at regular intervals to allow the metal ion levels to be determined and undergo scans to allow the bone mineral density of the bone surrounding the implant to be monitored. DePuy decided to close this Study in 4Q 2009. The Study was terminated with effect from December 2010 to allow for the completion of the 5 year follow up assessments. Please note that subsequent to this decision DePuy voluntarily recalled the ASR products on 24 August 2010. Additional information regarding this voluntary recall and the follow-up of patients affected by the recall can be found at the following links http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/CON079157 and http://www.depuy.com/countries_list.
The purpose of this study is to monitor the performance and determine the metal ion release of the Pinnacle™ Cup with a metal-on-metal bearing combination in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments. A subset of patients will also have blood samples taken at regular intervals to allow the metal ion levels to be determined.
The purpose of this study is to compare the performance of 4 designs of the DePuy Ultima LX hip stem in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be randomly allocated to one of the 4 designs of the DePuy Ultima LX hip stem and will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments.