Cataract Clinical Trial
— PRECISEOfficial title:
Prospective Multicenter Evaluation of the Visual Performance of a Non-constant Aberration Correcting Aspheric Monofocal Intraocular Lens (Precise Study))
The aim of this study is to investigate the 3-month visual performance of the CT LUCIA 621P IOL, a hydrophobic aspheric monofocal IOL with a non-constant aspheric optic profile in adult patients 50 years of age or older who are undergoing cataract surgery.
Status | Not yet recruiting |
Enrollment | 44 |
Est. completion date | December 2024 |
Est. primary completion date | December 2024 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 50 Years and older |
Eligibility | Inclusion Criteria: 1. Be at least 50 years of age or older, male or female, of any race or ethnicity. 2. Presenting for uncomplicated bilateral cataract surgery for age-related cataract. 3. Planned bilateral cataract extraction with posterior chamber IOL implantation, via phacoemulsification with or without femtosecond laser assisted cataract surgery (FLACS). 4. Bilateral implantation of a CT LUCIA 621P IOL with a dioptric power between +10.00 D and +30.00 D and a target postoperative refraction of emmetropia (0.00 ±0.50 D). 5. Clear intraocular media other than cataract (i.e. no hyphema, vitreous hemorrhage) 6. No visual acuity limiting pathologies other than cataract. Best corrected postoperative visual acuity potential of 20/25 or better in both eyes as estimated by potential acuity meter or surgeon estimation. 7. Provide written informed consent and a signed HIPPA form. 8. Availability, willingness, ability, and sufficient cognitive awareness to comply with study examination procedures and the schedule for study visits and evaluations. Exclusion Criteria: 1. Corneal Astigmatism of >1.0 D. 2. Planned monocular cataract extraction. 3. Visual field loss which has an impact on visual acuity. 4. Subjects with intraoperative surgical complications in whom a CT LUCIA 621P IOL cannot be implanted. 5. History of acute or chronic disease, pathology, illness, or ocular trauma that would, in the surgeon's opinion, confound results (e.g., corneal pathology, keratoconus, strabismus, uncontrolled glaucoma) 6. History of Glaucoma, macular degeneration, cystoid macular edema, proliferative diabetic retinopathy, amblyopia, etc. 7. Previous intraocular or corneal surgery, including all forms of refractive surgery that might confound the outcome of the investigation or increase the risk to the subject 8. Previous anterior or posterior chamber surgery other than peripheral retinal barrier laser, SLT/ALT (e.g., vitrectomy, laser iridotomy) 9. Pupil abnormalities (non-reactive, tonic pupils, abnormally shaped pupils or pupils that do not dilate under mesopic/scotopic conditions). 10. Capsular or zonular abnormalities or other conditions that increase the risk of zonular rupture during cataract extraction procedure and/or may affect the postoperative centration or tilt of the lens 11. Use of a systemic or ocular medication that might affect vision and confound the outcome or increase the risk to the subject in the opinion of the investigator such as tamsulosin hydrochloride (Flomax) or other medications with similar side effects (floppy iris syndrome) 12. Cycloplegic pupil diameter <6.0 mm or the presence of ocular implants that limit pupil diameter (malyugin rings; iris prosthesis). 13. Usage of contact lenses during study participation 14. Pregnant, lactating during the course of the investigation, or has another condition with associated fluctuation of hormones that could lead to refractive changes 15. Presence or history or any other condition or finding that, in the investigator's opinion, makes the subject unsuitable as a candidate for study participation, may increase the operative risk or may confound the outcome of the study. |
Country | Name | City | State |
---|---|---|---|
n/a |
Lead Sponsor | Collaborator |
---|---|
Carl Zeiss Meditec AG |
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Monocular best corrected distance visual acuity (CDVA) | The primary efficacy endpoint is the proportion of patients with monocular CDVA of 20/40 or better at three months | Three (3) Months | |
Secondary | Binocular Corrected Distance Visual Acuity | Three (3) Months | ||
Secondary | Binocular Uncorrected Corrected Distance Visual Acuity | Three (3) Months | ||
Secondary | Monocular Uncorrected Visual Acuity | Three (3) Months | ||
Secondary | Monocular Distance Corrected Intermediate Visual Acuity | Three (3) Months | ||
Secondary | Monocular Uncorrected Intermediate Visual Acuity | Three (3) Months | ||
Secondary | Manifest Refraction Spherical Equivalent | Three (3) Months | ||
Secondary | Refractive Predictability | Manifest refraction will be evaluated at 1 and 3 months to determine refractive predictability. The predicted refraction is the goal or target refraction from the IOLMaster IOL calculation and the observed refraction is the 3 Month postoperative Manifest Refraction Spherical Equivalent measurement. | Three (3) Months | |
Secondary | Refractive Stability | Manifest refraction will be obtained at 1 and 3 months to evaluate whether refractive stability is achieved by 3 months. Refractive stability will be evaluated at the 1 to 3 months interval as a parameter of interest to determine the proportion of eyes that achieve stability of manifest refraction. | Three (3) Months | |
Secondary | Contrast Sensitivity - mesopic and photopic with and without glare | Three (3) Months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |