Clinical Trial Summary

The goal of this observational study is to learn about the verification of the effectiveness and visual acuity of LUMINA in patients after lens replacement due to cataracts. The main questions it aims to answer are: - Evaluation of the effectiveness of the LUMINA lens in patients after lens replacement due to cataracts - Evaluation of the accommodative power of the LUMINA lens. Participants will have cataract surgery and the IOL LUMINA will be implanted in the sulcus.


Clinical Trial Description

This is an observational, prospective, longitudinal, and consecutive study involving patients with clinical cataract eligible for cataract surgery who opt for the implantation of the Lumina (Akkolens, Clinical BV, The Netherlands) accommodative lens. The study was conducted at the Cornea, Cataract, and Refractive Surgery Unit in Vissum Alicante, Miranza Group, Spain. The study adhered to the tenets of the Declaration of Helsinki (2013 version )and was approved by the Comite Etico de Investigacion Clinica Vissum Alicante. The study group included 50 eyes of 25 patients, aged 40 to 81 years (mean 62.27 ± 10.81 years), with clinical cataract who were implanted with the Lumina accommodative IOL. The inclusion criteria of this study were as follows: patients with visual significant cataract with an expected positive effect of the surgery on the visual outcome. The patient had to be ≥ 40 years of age and with a calculated IOL power within the available diopter range. The exclusion criteria were comorbidities causing postoperative visual impairment such as degenerative macular pathology, glaucoma with optic disk damage and visual field loss, retinal dystrophies previous ocular surgeries such as vitrectomy , corneal graft surgery, lens subluxation or significant eye trauma that may induce lens instability, congenital ocular anomalies, endothelial cell count < 1200 cells/mm2 and previous known reading disabilities such as dyslexia. Only patients with less than 2 diopters (D) of corneal astigmatism were included in the study with no significant corneal irregularities (less than 0.5 microns of anterior corneal surface HOA) as measured by corneal topography (CSO, Costruzione Strumenti Oftalmici, Firenze, Italy). All patients were adequately informed and signed a consent form. Preoperatively, all patients had a full ophthalmologic examination including the evaluation of the refractive status, keratometry, the distance and near visual acuities, slit lamp examination, applanation tonometry, and funduscopy. Distance and near visual acuity were measured with the ETDRS and the Radner reading chart (logarithm of reading acuity determination, logRAD), respectively. Other examinations included corneal topography Sirius/MS-39 (CSO, Costruzione Strumenti Oftalmici, Firenze, Italy), anterior segment optical coherence tomography MS-39 (CSO, Costruzione Strumenti Oftalmici, Firenze, Italy) or Casia2 (Tomey, Japan), posterior segment optical coherence tomography Cirrus OCT (Zeiss, Germany) and biometry IOL master 700 (Zeiss, Germany). The fixed optical power of the lens (i.e., the power required for an emmetropic eye) was calculated from optical biometry (IOL Master; Zeiss) by using proprietary Cþþ software integrated with Zemax ray-tracing software (Zemax, USA). The target refraction was plano in all cases that were included. The same surgeon (JLA) performed all surgeries. All patients received retrobulbar anesthesia and mild sedation with midazolam. Adequate dilatation was obtained with intracameral mydriatics. The main corneal incision of 2.8 mm was placed temporally at the 180° meridian position in all eyes. A standard technique of phacoemulsification was performed followed by implantation of the Lumina in the sulcus plane of the eye by using a standard disposable injector system with an adapted, proprietary, AkkoLens butterfly cartridge. Postoperative topical therapy included a combination of topical antibiotics (ofloxacin 0.3%) and a steroid agent (dexamethasone 0.1%, Maxidex; Alcon, Spain). The patients were evaluated during the follow up at five intervals: 1 day, 1 month, 3 months 6 months and a minimum of 12 months after surgery. In addition to the measurements listed in the preoperative protocol, the postoperative protocol included additional assessments of contrast sensitivity function in mesopic conditions (CSV 1000, VectorVision Ocular Health, Greenville, Ohio, USA) and the defocus curves. Monocular defocus curves were obtained with best distance refractive correction under low ambient light to keep an open pupil to minimize the undesirable effect of extended depth of focus owing to a small pupil, which can mask true accommodation. Negative and positive spherical lenses were added in 0.50 D steps, producing a stimulus for the eye to accommodate in the range from -5.00 to +2.00 D. The means of the measured visual acuities are summarized in mean defocus curves in which the measurements at 0.00 D and-2.50 D correspond to corrected distance visual acuity (CDVA) and corrected distance near visual acuity (CDNVA), respectively, and intermediate visual acuity corresponds to the measurement at -1.50 D. Depth of focus was evaluated from defocus curves at the levels of visual acuity of 0.10, 0.20, and 0.40 logMAR. The depth of focus for a particular eye was defined as the width of the defocus curve, in diopters, at a given level of visual acuity. The retinal optical quality was obtained using pyramidal aberrometry (Osiris, CSO, Italy) and optical quality analyzer system (OQAS, Visiomettrics SL, Spain) obtaining the MTF and PSF for different diameters and open field aberrometer (OFA, CSO, Italy) measured for distance and near. Main outcome measures Primary: Distance and near visual acuities, defocus curve, accommodation, depth of focus. Secondary: Contrast sensitivity function, optical quality assessment, PROMs (quality of vision and quality of life reported by the patients), complications. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06231784
Study type Interventional
Source Vissum, Instituto Oftalmológico de Alicante
Contact
Status Completed
Phase N/A
Start date June 9, 2016
Completion date December 2023

See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A