Cataract Clinical Trial
Official title:
Multifunctional Cataract Surgery Assistive Instruments Used in Cataract Surgery
In order to better cope with complex situations of cataract surgery, we designed and improved a new set of multi-functional cataract surgery auxiliary devices, including ophthalmic surgery auxiliary hooks, eye retractor hooks and membranous cataract scissors. Their common feature is that they have the function of 2-3 traditional surgical instruments, which can be switched in operations, reducing the replacement of different surgical instruments, lowing the number of surgical instruments in and out of the incision, reducing trauma and improving surgical efficiency. The purpose of this multi-center prospective clinical study is to verify the advantages of this new group of multifunctional devices and further summarize the experience and improvement by comparing the safety and effectiveness of traditional cataract surgical instruments combined with new multifunctional cataract assisted surgical instruments and traditional cataract surgical instruments alone.
Cataract is the number one cause of blindness, and the main treatment method is surgery to remove the cloudy lens and install an intraocular lens. The operation relies on ophthalmic micromanipulative instruments, but in complex cases such as abnormal lens capsule, ocular trauma, etc., the difficulty of surgery increases, so that conventional instruments are often unable to complete the operation well. In order to better cope with these complex situations, we designed and improved a new set of multi-functional cataract surgery auxiliary devices, including ophthalmic surgery auxiliary hooks, eye retractor hooks and membranous cataract scissors, which have obtained utility model patents and first-class medical device filings. Their common feature is that they have the function of 2-3 traditional surgical instruments, which can be switched intraoperatively, reduce the replacement of different surgical instruments, reduce the number of surgical instruments in and out of the incision, reduce trauma and improve surgical efficiency. The purpose of this multi-center prospective clinical study is to verify the advantages of this new group of multifunctional devices and further summarize the experience and improvement by comparing the safety and effectiveness of traditional cataract surgical instruments combined with new multifunctional cataract assisted surgical instruments and traditional cataract surgical instruments alone. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |