Cataract Clinical Trial
Official title:
Comparison of Clinical Outcome After Implantation With Two Different Multifocal Toric Intraocular Lens: Liberty Trifocal 677MTY (Medicontur) and PanOptix® Multifocal Toric (Alcon) Lens, With Respect to Rotational Stability, Visual Outcomes, Patients' Satisfaction, YAG Capsulotomy Rate
This study is to compare the rotational stability, visual outcome and patient satisfaction after implantation with either Liberty 677MTY, a multifocal diffractive-refractive IOL based on EPS technology manufactured by Medicontur Ltd. (Zsámbék, Hungary) or the multifocal toric IOL PanOptix®, manufactured by Alcon.
According to numerous estimations, 15% to 29% of patients with cataract have more than 1.5 diopters of refractive astigmatism. Corneal astigmatism can be reduced with a variety of surgical techniques including selective positioning of the phacoemulsification incision, corneal relaxing incision, implantation of toric IOLs, photorefractive keratectomy and there are first results of implantation of short arc-length intrastromal corneal ring segments for correcting astigmatism and myopia . The use of toric IOLs to reduce visually significant keratometric astigmatism offers a rational, more predictable and stable method of refractive correction. Implanting a toric intraocular lens offers the possibility of correcting not only spherical equivalent of refraction, but also astigmatism. The success of a toric IOL can be judged not only by its ability to reduce refractive astigmatism immediately postoperatively, but also by its ability to maintain a stable position in the capsular bag in the longer term. Even a small rotational deviation of the toric IOL from its intended axis can result in large reduction of the astigmatic correction. The purpose of this study is to evaluate and compare the visual outcomes, glass independency, visual disturbances (glares, halos), neuronal adaptation and patient satisfaction after implantation with either Liberty 677MTY , a multifocal diffractive apodized toric intraocular lens-- diffractive-refractive IOL based on EPS technology manufactured by Medicontur Ltd. (Zsámbék, Hungary) or the multifocal toric PanOptix®, manufactured by Alcon. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |