Cataract Clinical Trial
Official title:
Assessment of Reading Performance in Patients With Acrysof IQ Vivity Toric or Non-toric vs Monofocal Acrysof IQ Toric or Non-toric IOL
Comparison of the visual function and reading performance between the Acrysof IQ Vivity IOL, an EDOF IOL, and the monofocal Acrysof IQ.
With increasing demands of patients concerning their visual function after cataract surgery, a variety of advanced technology intraocular lenses (IOL) have become available in the last years. Various developments aim at a reduced spectacle independence for patients after cataract or refractive lens surgery. Novel technology for providing an extended depth of focus (EDOF) has been developed to account for unmet needs of patients. A novel EDOF IOL, the Acrysof IQ Vivity, has two surface transition elements that work simultaneously by stretching and shifting the wavefront to create a continuous extended focal range instead of multiple focal points. To assess the performance of such an IOL technology, most studies assess visual acuity at different distances from far, to intermediate up to near. Since most activites with digital devices implicate reading, it is not surprising that reading difficulty is the most common complaint among individuals experiencing visual disturbances with multifocal designs. Reading ability is usually evaluated using various reading tests that assess reading speed and reading acuity defined as the print size that can stell be read with sufficient speed. However, one of the fundamental problems of these tests is that reading speed is also influenced by the average amount of time that a patient reads as well as the language of the text, whether it is the first or second language. A novel method to analyse reading performance that appears to be more objective and less reliant on the cognitive abilities of the patient is the observation of the reading pattern using a high-speed eye-tracking system that analyses eye fixations during the reading test. In previous studies we have seen that several aspects of this reading patter, i.e. fixation duration and fixation frequency, appear to correlate with the reading performance overall and can be differentially used to discriminate between cognitive and visuo-motor processing. Hence, the aim of this study is to assess the visual function and reading performance with an EDOF IOL (Acrysof IQ Vivity) compared to a standard monofocal IOL (Acrysof IQ). 136 eyes of 68 patients will be included into this study. According to the randomization, 34 patients will be implanted with the Acrysof IQ Vivity in both eyes and the other 34 patients will be implanted with the Acrysof IQ in both eyes. A follow-up examination will be performed at 3 months postoperative. During this visit a slitlamp examination, biometry and tomography of the eye, refraction and visual acuity assessment, an OCT examination, a retroillumination photogrypha, reading speed analysis and halometry will be performed. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |