Evaluation of the rotational stability of a new toric intraocular lens (IOL), the TECNIS Eyhance toric II.


Clinical Trial Description

With increasing demands of patients concerning the refractive outcome after cataract surgery, toric intraocular lenses (IOLs) have become more popular. Originally, toric IOLs were used mainly to correct corneal astigmatism in patients with high degrees of astigmatism. Since a couple of years, toric IOLs are available from numerous manufacturers to correct moderate or even low amounts of astigmatism which are much more prevalent. Only about 8% of the population has a corneal astigmatism of 2.0 D or more, while the incidence of a corneal astigmatism of 0.75 D or more is about 30%. The use of toric IOLs in this population results in less spectacle dependence due to the astigmatic correction. Toric IOLs became the gold standard to correct corneal astigmatism during cataract surgery and rotational stability and axis alignment are critical to the efficacy of the surgical outcome. Misalignment may be caused intra- or postoperatively. Intraoperatively, misalignment may happen due to cyclotorsion of the eye in supine position or due to peribulbar anaesthesia and imprecision of positioning the IOL along the correct meridian in the capsular bag. This can be compensated for by preoperative corneal marking in the sitting position and meticulous positioning of the IOL during surgery. However, there are several other risk factors that influence rotational stability in the postoperative period, such as IOL design, haptic design and material, axial length, capsulorhexis size, capsular bag diameter and capsular bag shrinkage. Long-term success of toric IOLs depends on rotational stability, nevertheless rotation mostly happens in the early postoperative period and once the anterior and posterior capsules fuse, IOL rotation is less frequent. A study by Kim et al. showed no significant differences in lens rotation between the early and late postoperative follow-up, and Kwartz et al. showed no significant differences between the two periods when different lens materials were used. Varsits et al. reported that rotation of toric IOLs is typically seen within the first hour after implantation. It is known that tilt and decentration of the IOL can lead to a negative effect on optical performance and horizontal tilt induces against-the-rule-astigmatism. Every degree of rotation results in a loss of 3.3% of cylindrical power and misalignment of more than 10 degrees is considered an indication of surgical repositioning. The aim of this study is therefore to evaluate the rotational stability of the TECNIS Eyhance toric II intraocular lens. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05126368
Study type Interventional
Source Vienna Institute for Research in Ocular Surgery
Contact Johannes Zeilinger, MD
Phone +43 1 91021
Email [email protected]
Status Recruiting
Phase N/A
Start date April 29, 2021
Completion date November 29, 2022

See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Recruiting NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Recruiting NCT05053620 - Astigmatism Correction With Intrastromal Arcuate Incisions in Eyes Undergoing Cataract Surgery With Femtosecond Laser Using the Cassini Ambient With Iris Registration (ARCUATAS)
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A
Terminated NCT03145116 - Clinical Safety and Efficacy of CT ASPHINA 509 Lenses N/A
Recruiting NCT04566237 - Objective Measurements of the Opacification of the Lens After Vitrectomy N/A
Recruiting NCT04631068 - Clinical Comparison of a Monofocal eDOF IOL With a Monofocal IOL N/A
Completed NCT03309020 - PREVAIL VII: Cataract Surgery in Ebola Survivors N/A