Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04943809
Other study ID # Poyales/POD FT - POD F
Secondary ID
Status Completed
Phase
First received
Last updated
Start date July 16, 2014
Est. completion date July 20, 2017

Study information

Verified date June 2021
Source Beaver-Visitec International, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

There is no difference of the photic phenomena in the two groups. The study will be a prospective non-randomised controlled study. The target is then to determine the equivalence in the glare. Assumption of Type I error is p=0.05 as level of significance and Type II error is alpha=0.8 as power.


Description:

The study will be a prospective non-randomised controlled study. The target is then to determine the equivalence in the glare. Assumption of Type I error is p=0.05 as level of significance and Type II error is alpha=0.8 as power. We used the 'TrialSize' package of the R software. Here are the parameters defined for the sample size calculation: 1. Alpha: 0.05 2. Power : 0.90 3. Two sided test 4. Equal group allocation 5. Standard deviation for the two groups (POD 26P AY F et POD 26P AY FT) equal to 0.10 6. Expected mean for the two groups (POD 26P AY F et POD 26P AY FT) equal to 0.89 (true difference between the means equal 0) 7. An equivalence limit of 0.05, 0.10 and 0.15 Equivalence limit: 0.15 In order to show no difference between these two groups, 12 patients by groups are needed. With a drop-out of 15%, we obtain 30 patients (15 patients by group) to recruit in order to obtain 24 valuable patients. Equivalence limit: 0.10 In order to show no difference between these two groups, 26 patients by groups are needed. With a drop-out of 15%, we obtain 62 patients (31 patients by group) to recruit in order to obtain 52 valuable patients. This total number of subjects with such requirement is 26 patients in each group. Group 1 will be made of 26 patients with corneal astigmatism higher than 1.0D in both eyes and lower than 2.5D and will be implanted with the POD 26P AY FT and Group 2 will be made of 26 patients with corneal astigmatism lower than 1.0D in both eyes. Interim analysis after the 12th patient of each group will have completed the last follow-up will be achieved to confirm the equivalence with the equivalence limit of 0.15. The POD platform in 26 % (non toric version) is available since 2008 in the monofocal version and since 2012 in the toric one (POD 6P AY T, Ankoris®, PhysIOL).The so-called POD design is characterised by two symmetrical bifid haptics with opened loops that provide four points of support to ensure IOL stability in the capsular bag. The dual C-loop profile shortens the loops, thus improving the pliability of the implant during its injection through a micro-incision. These shortened loops should permit a clockwise or anticlockwise rotary motion and should facilitate the comfortable fitting of the implant orientation after unfolding without elastic-restoring torque. The double C-loop POD design offers 4 support points for the implant within the capsule and ensures its stability. The V-shape of the upper and lower haptics together with the flexibility of the implant allow the loop separation angle to be adjusted and ensure the most accurate adaptation to the capsular bag size. A finite element structural analysis of the implant showed that the elasticity at the distal part of the loop prevents the constraints from being transmitted onto the optical portion of the implant. The trifocal optic is associated to the POD platform and is made of 26 % raw material. The rotational stability of this non toric version has been clinically investigated on 117 consecutive eyes 1 week, 3 weeks, 3 and 12 months after implantation. The absolute rotation of the lens averaged 2.5 ± 2.6°. The position of the center of the implant relative to the pupillary center expressed by a vector was 0.01 mm at 70°. The investigational product (POD 26P AY FT) is CE labeled since January 2014. Main IOL features are: - Biconvex toric aspheric (-0.11um SA) blue-blocking, hydrophilic acrylic IOL with 26% equlibrium water content, implantable through ≥ 2.2mm incision. - 4-point haptic design - 6 mm of optical diameter / 11.4 mm of total diameter - Dioptric range (SE): 6 to 35 D by 0.5 D increments - Cylinders at the IOL plane: 1, 1.5, 2.25, 3, 3.75, 4.5, 5.25, 6 D - Addition +1.75D / +3.5 D The control product (POD 26P AY F) is CE labeled since 2010. Main IOL features are: - Biconvex, aspheric (-0.11um SA) blue-blocking, hydrophilic acrylic IOL with 26% equlibrium water content, implantable through ≥ 2.2mm incision. - 4-point haptics design which minimizes decentration and optimizes the rotational stability - 6 mm of optical diameter / 11.4 mm of total diameter - Dioptric range (SE): 6 to 35 D by 0.5 D increments - Addition +1.75D / +3.5 D


Recruitment information / eligibility

Status Completed
Enrollment 63
Est. completion date July 20, 2017
Est. primary completion date July 20, 2017
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 21 Years and older
Eligibility Inclusion Criteria: - Age-related cataract - Preoperative Corneal astigmatism < 0.75 D - Age 21 and older - Visual Acuity > 0.05 - Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant. - Patient willing multifocal implantation and with realistic expectations. Exclusion Criteria: - Relevant other ophthalmic diseases such as pseudoexfoliation syndrome, floppy iris syndrome, corneal pathologies, retinal pathology (diabetic maculopathy, myopic maculopathy, age related macular degeneration...) - Previous ocular surgery or trauma.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
POD 26P AY FT
Routine cataract surgery
POD 26P AY F
Routine cataract surgery

Locations

Country Name City State
Spain Hospital Clínico San Carlos Madrid

Sponsors (1)

Lead Sponsor Collaborator
Beaver-Visitec International, Inc.

Country where clinical trial is conducted

Spain, 

References & Publications (12)

Alfonso JF, Knorz M, Fernandez-Vega L, Rincón JL, Suarez E, Titke C, Kohnen T. Clinical outcomes after bilateral implantation of an apodized +3.0 D toric diffractive multifocal intraocular lens. J Cataract Refract Surg. 2014 Jan;40(1):51-9. doi: 10.1016/j — View Citation

Bellucci R, Bauer NJ, Daya SM, Visser N, Santin G, Cargnoni M, Nuijts RM; Lisa Toric Study Group. Visual acuity and refraction with a diffractive multifocal toric intraocular lens. J Cataract Refract Surg. 2013 Oct;39(10):1507-18. doi: 10.1016/j.jcrs.2013 — View Citation

Chassain C, Pagnoulle C, Gobin L, Rozema J. [Evaluation of a new intraocular lens platform: centration and rotational stability]. J Fr Ophtalmol. 2013 Apr;36(4):336-42. doi: 10.1016/j.jfo.2012.04.012. Epub 2013 Jan 24. French. — View Citation

Cochener B, Vryghem J, Rozot P, Lesieur G, Heireman S, Blanckaert JA, Van Acker E, Ghekiere S. Visual and refractive outcomes after implantation of a fully diffractive trifocal lens. Clin Ophthalmol. 2012;6:1421-7. doi: 10.2147/OPTH.S32343. Epub 2012 Sep — View Citation

de Vries NE, Nuijts RM. Multifocal intraocular lenses in cataract surgery: literature review of benefits and side effects. J Cataract Refract Surg. 2013 Feb;39(2):268-78. doi: 10.1016/j.jcrs.2012.12.002. Review. — View Citation

Ferreira TB, Marques EF, Rodrigues A, Montés-Micó R. Visual and optical outcomes of a diffractive multifocal toric intraocular lens. J Cataract Refract Surg. 2013 Jul;39(7):1029-35. doi: 10.1016/j.jcrs.2013.02.037. Epub 2013 May 13. — View Citation

Knorz MC, Rincón JL, Suarez E, Alfonso JF, Fernández-Vega L, Titke C, Kohnen T, Tucker S. Subjective outcomes after bilateral implantation of an apodized diffractive +3.0 D multifocal toric IOL in a prospective clinical study. J Refract Surg. 2013 Nov;29( — View Citation

Roensch MA, Charton JW, Blomquist PH, Aggarwal NK, McCulley JP. Resident experience with toric and multifocal intraocular lenses in a public county hospital system. J Cataract Refract Surg. 2012 May;38(5):793-8. doi: 10.1016/j.jcrs.2011.11.043. Epub 2012 — View Citation

Sheppard AL, Shah S, Bhatt U, Bhogal G, Wolffsohn JS. Visual outcomes and subjective experience after bilateral implantation of a new diffractive trifocal intraocular lens. J Cataract Refract Surg. 2013 Mar;39(3):343-9. doi: 10.1016/j.jcrs.2012.09.017. Ep — View Citation

Visser N, Bauer NJ, Nuijts RM. Toric intraocular lenses: historical overview, patient selection, IOL calculation, surgical techniques, clinical outcomes, and complications. J Cataract Refract Surg. 2013 Apr;39(4):624-37. doi: 10.1016/j.jcrs.2013.02.020. R — View Citation

Visser N, Nuijts RM, de Vries NE, Bauer NJ. Visual outcomes and patient satisfaction after cataract surgery with toric multifocal intraocular lens implantation. J Cataract Refract Surg. 2011 Nov;37(11):2034-42. doi: 10.1016/j.jcrs.2011.05.041. Epub 2011 S — View Citation

Wolffsohn JS, Jinabhai AN, Kingsnorth A, Sheppard AL, Naroo SA, Shah S, Buckhurst P, Hall LA, Young G. Exploring the optimum step size for defocus curves. J Cataract Refract Surg. 2013 Jun;39(6):873-80. doi: 10.1016/j.jcrs.2013.01.031. — View Citation

* Note: There are 12 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Determine the equivalence of the glare The primary endpoint is to show statistically equivalent outcomes on glare at the 3 months follow up visit. A significance level of p = 0.05 will be considered statistically significant. 3 Months
Secondary Measurement of far, intermediate and near visual acuity The secondary objective is to measure far, intermediate and near visual acuity of the POD AY 26P FT with respect to the POD AY 26P F. 6 Months
Secondary Refraction The secondary objective is to measure the refraction of the POD AY 26P FT with respect to the POD AY 26P F. 6 Months
Secondary Centration The secondary objective is to measure the centration of the POD AY 26P FT with respect to the POD AY 26P F. 6 Months
Secondary Rotational stability The secondary objective is to measure the rotational stability of the POD AY 26P FT with respect to the POD AY 26P F. 6 Months
Secondary Equivalence of the visual acuity and the contrast sensitivity The secondary objective is to determine the equivalence of the visual acuity of the POD AY 26P FT with respect to the POD AY 26P F. 6 Months
Secondary Equivalence of the visual acuity and the contrast sensitivity The secondary objective is to determine the contrast sensitivity at far of the POD AY 26P FT with respect to the POD AY 26P F. 6 Months
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A