Cataract Clinical Trial
Official title:
Clinical Outcome After Implantation of Medicontur Multifocal, Toric Intraocular Lens Liberty 677MTY: Rotational Stability, Visual Outcomes, Patients' Satisfaction, YAG Capsulotomy Rate
The purpose of this study is to evaluate visual outcomes, patient satisfaction and YAG capsulotomy rate after implantation of a multifocal toric lens- Liberty 677MTY - manufactured by Medicontur Ltd. (Zsámbék, Hungary),
The purpose of this study is to evaluate visual outcomes, glass independency, visual disturbances (glares, halos), neuronal adaptation and patient satisfaction after implantation of multifocal diffractive apodized toric intraocular lens- Liberty 677MTY - diffractive-refractive apodized IOL based on EPS technology manufactured by Medicontur Ltd. (Zsámbék, Hungary). The tested IOL model, Liberty 677MTY, has an overall length of 13 mm, an optic diameter of 6.0 mm without haptics angulations but with posterior vaulting. The refractive index of the optic material is 1.46 (at 23°C). The IOL is a single-piece-IOL, the optic and haptics are made from a hydrophilic acrylic co-polymer with integrated - covalently bound UV absorbent. The IOL is produced with yellow filter, covalently bound yellow chromophore. The toric component of Liberty 677MTY IOL is located on the posterior surface of the lens optic. The optic is marked with 2 marks. The marks are positioned exactly in middle between the two loops of haptic at the angulation at the flat axis of toric equivalent. The Liberty 677MTY is available with cylinder powers of 1.0 diopter (D) to 6.0 D. The IOL is designed with sharp edge following 360º to prevent migration of the lens epithelial cells , thereby to prevent PCO formation. The trifocality of the lens is provided by the EPS technology recently developed by Medicontur uses an elevated phase shift on the central diffractive part of the lens in order to cause constructive interference between the 0th (far) and 1st diffractive (near) order, thus creating a 3rd (intermediate) focal point. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |