Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT04591054
Other study ID # 15524
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date November 20, 2020
Est. completion date August 24, 2022

Study information

Verified date August 2023
Source Milton S. Hershey Medical Center
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to compare the binocular distance, intermediate, and near visual acuity of the Alcon Vivity and Bausch & Lomb enVista IOLs. We hypothesize that the Alcon Vivity and Bausch & Lomb enVista IOLs will have similar distance, intermediate, and near visual acuity. If the null hypothesis is rejected, then the visual performance of the IOLs may be different.


Description:

Presbyopia correcting intraocular lens (PC-IOL) technology has been available for decades. Lens designs have included refractive (e.g. AMO ReZoom), apodized diffractive (e.g. Alcon Acrysof ReSTOR/PanOptix), accommodating (B&L Crystalens), and extended depth-of-focus (e.g. J&J Symfony) technology. Spectacle independence is significantly higher with PC-IOLs when compared with that of monofocal IOLs.1,2 Despite their clear benefits, PC-IOLs are not without drawbacks. Any IOL that splits light to deliver distinct distance and near foci creates the potential for photic phenomenon, which patients may perceive as glare, haloes, and starbursts.3,4 Pseudoaccommodation is defined as an increased depth-of-focus in an emmetropic eye that does not have the ability to change its refractive power. Spherical aberration, which may come from the cornea or IOL, plays an important role in pseudoaccommodation.5,6 There is a small body of literature that IOLs (e.g. Mini WELL, SIFI, Catalina, Italy) with highly-positive spherical aberration can result in significant pseudoaccommodation and lower unwanted optical phenomena than current multifocal IOLs.7 The Alcon Vivity PC-IOL is a hydrophobic acrylic, non-diffractive, extended depth of focus IOL designed for implantation in the capsular bag following cataract extraction. The single-piece IOL has a 6.0 mm diameter and has a hyper-prolate profile that extends the depth of focus to deliver a broader range of sharp vision, with the glare and halo profile approaching that of a monofocal IOL.8 The Bausch & Lomb enVista MX60E is a posterior chamber hydrophobic acrylic IOL. The single-piece IOL has a 6.0 mm diameter and has a neural aspheric optical profile. This neutral aspheric profile, combined with the cornea's natural positive spherical aberration, may extend the depth of focus relative to other negative aspheric hydrophobic acrylic monofocal IOLs on the market. To date, there is no existing literature comparing the visual performance and patient reported outcomes of the two above mentioned lens technologies; namely, one that relies on a non-diffractive, hyper-prolate profile and another that relies on the cornea's natural positive spherical aberration to provide pseudoaccommodation. The FDA Summary of Safety and Effectiveness on the Alcon Vivity IOL compares visual and patient reported outcomes of the Alcon Vivity IOL and the Alcon Acrysof SN60WF. While the Alcon Acrysof SN60WF and Bausch & Lomb enVista lenses are not identical, they are considered similar. The document reported improved intermediate vision with the Alcon Vivity over the SN60WF, and rates of reported visual disturbances were similar between the two devices. Whereas the Alcon Acrysof SN60WF has a negative aspheric optical profile, the Bausch & Lomb enVista has a neutral aspheric optical profile. Theoretically, the Bausch & Lomb enVista IOL may provide increased intermediate vision compared with the SN60WF.


Recruitment information / eligibility

Status Completed
Enrollment 56
Est. completion date August 24, 2022
Est. primary completion date July 26, 2022
Accepts healthy volunteers No
Gender All
Age group 18 Years to 95 Years
Eligibility Inclusion Criteria: - Male or female, age 18 or older at the time of study enrollment. - Visually significant cataract in the study eyes for which phacoemulsification cataract extraction and posterior chamber IOL implantation is indicated. - Anticipated to undergo bilateral sequential cataract surgery - Projected postoperative CDVA 0.20 logMAR (Snellen 20/32) or better in the study eyes, as determined by an Investigator's medical judgement. - Calculated spherical power targeted at emmetropia at distance in the study eyes. - Calculated IOL power between +15.0 - +25.0 D, inclusive, in both eyes. - Measured against-the-rule astigmatism less than 0.6 D or with-the-rule/oblique astigmatism less than 1.25 D. - If wearing rigid gas permeable (RGP) contact lens in the study eye, willingness to discontinue lens wear for = 21 days prior to preoperative biometry. - Availability, willingness, and sufficient cognitive awareness to return for study-required visits and comply with examination procedures. - Willingness to sign the IRB-approved informed consent form (ICF) for study participation. Exclusion Criteria: - Mature cataract in the study eye that is likely to prolong surgical procedure and/or lead to intraoperative complications prior to attempted IOL implantation. - Any visually significant intraocular media opacity other than cataract in the study eye (as determined by the investigator). Such opacities might include corneal scar or vitreous hemorrhage. - Abnormal corneal findings in the study eye (e.g. keratoconus, pellucid marginal degeneration, irregular astigmatism). - Any anterior segment pathology in the study eye that could significantly affect outcomes (e.g. chronic uveitis, iritis, aniridia, clinically significant corneal dystrophies, poor pupil dilation, etc.) - Any condition in the study eye that could affect IOL stability (e.g. pseudoexfoliation, zonular dialysis, evident zonular weakness or dehiscence, etc.). - History of severe dry eye in the study eye that, in the judgement of the investigator, would impair the ability to obtain reliable study measurements. - History of serious corneal disease (e.g. herpes simplex, herpes zoster keratitis, etc.) in the study eye. - History of any clinically significant retinal pathology or ocular diagnosis in the study eye that could, in the investigator's best judgement, alter or limit final post-operative visual prognosis (e.g. diabetic retinopathy, ischemic disease, macular degeneration, retinal detachment, optic neuropathy, amblyopia, strabismus, aniridia, epiretinal membrane, etc.). - History of cystoid macular edema in either eye. - History of uveitis in either eye. - History of intraocular or corneal surgery in the study eye besides laser peripheral iridotomy (LPI), selective laser trabeculoplasty (SLT), or argon laser trabeculoplasty (ALT). - Uncontrolled glaucoma in the study eye (per Investigator judgement). - Current ocular infection in the study eye. - Presence of uncontrolled systemic disease that could increase operative risk (e.g. diabetes mellitus, mental illness, dementia, clinically significant atopic disease, etc.). - Planned concomitant ocular procedure during cataract surgery inclusive of glaucoma surgery e.g. MIGS or limbal relaxing incisions. - Symptoms that might be consistent with active COVID-19 including fever, chills, cough, shortness of breath or difficulty breathing, fatigue, muscle or body aches. - If COVID-19 positive, at least two weeks since last symptoms. - Unsuitable for study participation for any other reason, as determined by the Investigator's clinical judgement.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Extended Vision IOL
Vivity IOL implantation following cataract extraction
Neutral Aspheric Monofocal IOL
enVista IOL implantation following cataract extraction

Locations

Country Name City State
United States Penn State Hershey Medical Center Eye Center Hershey Pennsylvania

Sponsors (1)

Lead Sponsor Collaborator
Milton S. Hershey Medical Center

Country where clinical trial is conducted

United States, 

Outcome

Type Measure Description Time frame Safety issue
Primary Binocular Intermediate Vision Mean logMAR best-distance corrected visual acuity at intermediate (66 cm) tested in binocular photopic conditions at 3 months. 3 months
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A