Clinical Trial Summary

The study will be a multicentric, prospective open-label ethics committee approved clinical study to investigate safety, visual outcomes, contrast sensitivity and rotational stability after bilateral implantation of Isatis TF IOL following cataract surgery.


Description:

This is a staged, multicentric, controlled, prospective, open-label clinical study whereby patients undergoing routine cataract surgery will have bilateral implantation of hydrophobic acrylic refractive trifocal intraocular lenses (Isatis TF) or the monofocal control device Isatis. The investigational device, Control lens and all study products, including the devices used for the study examinations, will be used within the intended use specifications from the manufacturer. In addition, no invasive or other burdening examinations will occur for the patient. The study will be carried out in up to five clinical centers in Spain. The device under investigation is a hydrophobic acrylic trifocal intraocular lens (IOL) manufactured by the sponsor of this study. The trifocality of this investigational device is based on a purely refractive principle with the goal to provide additional near and intermediate visual acuity with low photic side effects. The IOLs will be implanted in the course of routine cataract surgery and will benefit to patients suffering from cataract development. The control device (Isatis) is a hydrophobic acrylic monofocal intraocular lens to be implanted during cataract surgery. This control lens is CE approved and commercially available in Spain. Isatis monofocal lens is the parent lens of the device under investigation and both lenses share mechanical and material properties. In total 180 patients will be recruited for this clinical study and undergo bilateral implantation of the Isatis TF intraocular lens or Isatis lens in a 2:1 ratio. Subjects participating in the trial will attend a total of maximum 11 study visits over a period of 11-13 months. Subjects would have the option for unscheduled visits if required medically. Data analyses will be performed after the last patient finished the 120-180 days postoperative examination.


Recruitment information / eligibility

Status Recruiting
Enrollment 180
Est. completion date July 2024
Est. primary completion date July 2024
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 50 Years and older
Eligibility Inclusion Criteria: - Clinically documented age-related cataract in both eyes with no comorbidity; - Calculated IOL power is within the range of the investigational IOLs; - Male or female adults ages 50 years or older on the day of screening who have cataracts in both eyes; - Regular corneal astigmatism (measured by topographer) - Astigmatism =1.0 D (measured by an automatic keratometer) - Clear intraocular media other than cataract; - Availability, willingness and sufficient cognitive awareness to comply with examination procedures; - Patient is willing to receive bilateral implantation of a trifocal IOL (this inclusion criteria applies only to the study group, not the control group); - Signed informed consent. Exclusion Criteria: - Age of patient < 50 years; - Regular corneal astigmatism >1.0 dioptres (measured by an automatic keratometer) - Irregular astigmatism (measured by topographer); - Difficulty for cooperation (distance from their home, general health conditions); - Subjects with diagnosed degenerative visual disorders (e.g. macular degeneration or other retinal or optic disorders); - Subjects with AMD suspicious eyes as determined by OCT examination; - Previous intraocular or corneal surgery; - Traumatic cataract; - Instability of keratometry or biometry measurements; Acceptable maximum standard deviation: AL: ± 150 µm; ACD: ± 150 µm; K1 / K2: ± 0.15 D; - Ocular hypertension, suspicious glaucoma or glaucoma; - Pupil abnormalities (non-reactive, tonic pupils, abnormally shaped pupils or pupils that do not dilate under mesopic / scotopic conditions); - Expected complicated surgery; - Ocular surface disease (clinical symptoms or keratitis); - Pregnancy or lactation; - Second eye treatment will only be performed when Best Corrected Distance Visual Acuity (CDVA) of first eye is = 0.2 logMAR (= 0.63 decimal); - Concurrent participation in another drug or device investigation. In addition to above mentioned in- and exclusion criteria, subjects shall be discontinued when certain conditions are present at the time of surgery, including: - zonular instability; - need for iris manipulation; - capsular fibrosis or other opacity; and - inability to fixate IOL in desired position. In such cases, the subject shall be followed until the condition has stabilized.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Implantation of trifocal IOL, Isatis TF (device under investigation)
Patients will be implanted with study IOL in both eyes
Implantation of monofocal IOL, Isatis (control device)
Patients will be implanted with Control IOL in both eyes

Locations

Country Name City State
Czechia Gemini Eye Clinic Ostrava Ostrava
Czechia Gemini Eye Clinic Praha-Krc Praha
Czechia Gemini Eye Clinic Zlín Zlín
Spain Hospital Donostia Donostia San Sebastian
Spain Hospital Universitario Clínico San Carlos Madrid
Spain Oftalvist Madrid Madrid
Spain Hospital Miguel Servet Zaragoza

Sponsors (2)

Lead Sponsor Collaborator
Cutting Edge SAS targomedGmbH

Countries where clinical trial is conducted

Czechia,  Spain, 

References & Publications (3)

Lundstrom M, Pesudovs K. Catquest-9SF patient outcomes questionnaire: nine-item short-form Rasch-scaled revision of the Catquest questionnaire. J Cataract Refract Surg. 2009 Mar;35(3):504-13. doi: 10.1016/j.jcrs.2008.11.038. — View Citation

McAlinden C, Pesudovs K, Moore JE. The development of an instrument to measure quality of vision: the Quality of Vision (QoV) questionnaire. Invest Ophthalmol Vis Sci. 2010 Nov;51(11):5537-45. doi: 10.1167/iovs.10-5341. Epub 2010 May 26. — View Citation

Morlock R, Wirth RJ, Tally SR, Garufis C, Heichel CWD. Patient-Reported Spectacle Independence Questionnaire (PRSIQ): Development and Validation. Am J Ophthalmol. 2017 Jun;178:101-114. doi: 10.1016/j.ajo.2017.03.018. Epub 2017 Mar 22. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Other Monocular Uncorrected Distance Visual Acuity (UDVA) under photopic light conditions Monocular UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. Preoperative, 1-2 days postoperative; 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Other Binocular Uncorrected Distance Visual Acuity (UDVA) under photopic light conditions Binocular UDVA is measured with ETDRS charts placed in 4m distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions. 120-180 days postoperative, 330-420 days postoperative
Other Monocular Corrected Distance Visual Acuity (CDVA) under photopic light conditions Monocular CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. Preoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Monocular Corrected Distance Visual Acuity (CDVA) under mesopic light conditions Monocular CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done binocularly under mesopic light conditions. 120-180 days postoperative
Other Binocular Corrected Distance Visual Acuity (CDVA) under photopic light conditions Binocular CDVA is measured with ETDRS charts placed in 4m distance with best aided corrective glasses according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions. 120-180 days postoperative
Other Monocular Uncorrected Intermediate Visual Acuity (UIVA) under photopic light conditions Monocular UIVA is measured with ETDRS charts placed in 66cm distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Other Binocular Uncorrected Intermediate Visual Acuity (UIVA) under photopic light conditions Binocular UIVA is measured with ETDRS charts placed in 66cm distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions. 120-180 days postoperative, 330-420 days postoperative
Other Monocular Uncorrected Near Visual Acuity (UNVA) under photopic light conditions Monocular UNVA is measured with ETDRS charts placed in 40cm distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Other Binocular Uncorrected Near Visual Acuity (UNVA) under photopic light conditions Binocular UNVA is measured with ETDRS charts placed in 40cm distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions. 120-180 days postoperative, 330-420 days postoperative
Other Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) under photopic light conditions Monocular DCIVA is measured with ETDRS charts placed in 66cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. Preoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Other Monocular Distance Corrected Intermediate Visual Acuity (DCIVA) under mesopic light conditions Monocular DCIVA is measured with ETDRS charts placed in 66cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under mesopic light conditions. 120-180 days postoperative
Other Binocular Distance Corrected Intermediate Visual Acuity (DCIVA) under photopic light conditions Binocular DCIVA is measured with ETDRS charts placed in 66cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions. 120-180 days postoperative
Other Monocular Distance Corrected Near Visual Acuity (DCNVA) under photopic light conditions Monocular DCNVA is measured with ETDRS charts placed in 40cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done monocularly under photopic light conditions. Preoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Other Monocular Distance Corrected Near Visual Acuity (DCNVA) under mesopic light conditions Monocular DCNVA is measured with ETDRS charts placed in 40cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under mesopic light conditions. 120-180 days postoperative
Other Binocular Distance Corrected Near Visual Acuity (DCNVA) under photopic light conditions Binocular DCNVA is measured with ETDRS charts placed in 40cm distance with corrective glasses for far distance according to ISO 11979-7:2018. This assessment is done binocularly under photopic light conditions. 120-180 days postoperative
Other Manifest refraction The manifest refraction is measured by means of a phoropter. The data contains values for sphere, cylinder and axis of cylinder according to ISO 11979-7:2018. This data will also be used to calculate the manifest refractive spherical equivalent (MRSE) Preoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Adjusted Mean Refractive Spherical Equivalent (MRSE) The predictability of the postoperative manifest refraction will be evaluated using the absolute value of the adjusted MRSE calculated by the following formula:
MRSEadjusted = MRSEpostop - MRSEtarget.
7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Other Binocular Defocus Curve To assess the visual acuity for different distances, defocus curves under photopic light conditions are measured. This test is performed with best distance corrected refraction and spherical additions ranging from -4.5 D to +2.0 D in 0.5 D steps. This examination is performed binocularly. 120-180 days postoperative
Other Binocular Contrast Sensitivity under photopic light conditions Contrast Sensitivity under photopic light conditions using the standardized contrast sensitivity device CSV-1000 (VectorVision). This examination is performed binocularly. 120-180 days postoperative
Other Binocular Contrast Sensitivity under mesopic light conditions Contrast Sensitivity under mesopic light conditions using the standardized contrast sensitivity device CSV-1000 (VectorVision). This examination is performed binocularly. 120-180 days postoperative
Other Binocular Contrast Sensitivity under photopic light conditions and using a glare source Contrast Sensitivity under photopic light conditions with a glare source using the standardized contrast sensitivity device CSV-1000 (VectorVision). This examination is performed binocularly. 120-180 days postoperative
Other Binocular Contrast Sensitivity under mesopic light conditions and using a glare source Contrast Sensitivity under mesopic light conditions with a glare source using the standardized contrast sensitivity device CSV-1000 (VectorVision). This examination is performed binocularly. 120-180 days postoperative
Other Patient reported outcomes - Quality of Vision questionnaire [McAlinden et al, 2010] To assess the subjective perception of disturbances by photic phenomena, the validated and verified Quality of Vision (QoV) questionnaire will be used.
This questionnaire is a linear-scaled 30-item instrument and is designed with 10 symptoms rated in each of three scales (frequency, severity, and bothersome).
The QoV Questionnaire provides a QoV score in terms of symptom frequency, severity, and bothersome [McAlinden et al, 2010].
preoperative, 120-180 days postoperative
Other Patient reported outcomes - Catquest-9SF 2011 questionnaire [Lundström et al, 2009] To assess if difficulties in daily life occur due to impaired sight. This questionnaire is a 9-item Rasch-scaled instrument to assess subjective perception of visual impairment after surgery [Lundström et al, 2009]. preoperative, 120-180 days postoperative
Other Patient reported outcomes - Patient-Reported Spectacle Independence Questionnaire (PRSIQ) [Morlock et al, 2017] The PRSIQ is a patient-reported measure assessing spectacle independence following cataract surgery. The analyses conducted provide evidence for the use of the PRSIQ total score as a measure of spectacle independence [Morlock et al, 2017]. preoperative, 120-180 days postoperative
Other Pupil Size under photopic light conditions Photopic pupil diameters are measured with a ruler allowing for a precision of at least +/-0.5 mm. In addition to the measurement with a ruler, pupil diameters under photopic light conditions will be recorded from the preoperative Pentacam measurement.
For the photopic pupil diameters, eye illumination should be identical to that used for photopic contrast sensitivity testing. Pupil measurements should only be made after the eye has had time to fully adapt to the testing conditions (at least 5 minutes).
The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
preoperative, 120-180 days postoperative
Other Pupil Size under mesopic light conditions Mesopic pupil diameters are measured with a ruler allowing for a precision of at least +/-0.5 mm. For the mesopic pupil diameters, eye illumination should be identical to that used for mesopic contrast sensitivity testing. Pupil measurements should only be made after the eye has had time to fully adapt to the testing conditions (at least 5 minutes).
The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
preoperative, 120-180 days postoperative
Other Fundus examination with dilated pupil The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
• Fundus
preoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - Corneal status The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
• Corneal Status
Preoperative, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - Iris status The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
• Iris Status
Preoperative, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - Signs of inflammation The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
Signs of inflammation
Anterior chamber cells,
Anterior chamber flare,
Cystoid macular oedema,
Hypopyon, and
Endophthalmitis.
Preoperative, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Other Slitlamp examination - Pupillary block The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
- Pupillary block.
1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - Retinal detachment The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
- Retinal detachment.
preoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - Status of anterior and posterior capsule The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
- Status of anterior and posterior capsule.
1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - IOL decentration The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
- IOL decentration.
1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - IOL tilt The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
- IOL tilt.
1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - IOL discoloration The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
- IOL discoloration.
1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Slitlamp examination - IOL opacity The slitlamp examination is one examination to analyse the integrity of eye structures and the implanted IOL. The examination is performed and documented according to the guidelines in ISO 11979-7:2018.
With the slitlamp the ophthalmologist can observe the eyes stereoscopically. A focussed slit of light, which can be width-adjusted, is projected on the eye to be examined. The investigator observes this projection on the eye through a reflected light microscope. The slitlamp is used to observe the anterior and posterior part of the eye, including cornea, lens and anterior chamber. By dilating the pupil the fundus can also be examined. Following conditions shall be examined with the slitlamp:
- IOL opacity.
1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Intraocular pressure (IOP) measurement The IOP will be measured with non-contact tonometer as part of the routine follow up examinations. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. Preoperative, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative, 330-420 days postoperative
Other Keratometry Keratometric measurements are performed to calculate the required IOL power. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. Preoperative
Other IOL power and target refraction The parameter of the implanted IOL must be recorded as well as the target refraction given by the IOL calculator. This parameter is needed to calculate the accuracy of achieving the target refraction. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. day of surgery
Other Fundus OCT An OCT (optical coherence tomography) image will be taken at the preoperative visit to identify AMD suspicious eyes that need to be excluded from this study. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. Preoperative
Other Biometry Biometry measurements are performed to calculate the required IOL power. The examination is performed and documented according to the guidelines in ISO 11979-7:2018. Preoperative
Other Corneal topography Pentacam device (Oculus, Germany) will be used to perform corneal topography. This examination is needed to exclude patients showing an irregular corneal astigmatism. Preoperative
Other Corneal aberrometry Pentacam device (Oculus, Germany) will be used to perform corneal aberrometry measurement. The following values will be evaluated in this study: Spherical aberrations, high order aberrations. Preoperative
Other IOL rotation To determine the rotational stability of the lenses after implantation, the actual IOL orientation has to be recorded as the intended surgical position during surgery using a photograph through the surgery microscope or within one hour after surgery using a photograph through a slit lamp to document the rotational position of the IOL. Additional orientations are measured and recorded at the follow up visits by taking retroilluminated photographs in mydriasis using the slit lamp.
To determine the rotational stability, it is important that the IOL axis marks of the IOL are visible as well as concurrent structures of the eye (in the same image) that are fixed and stable. Preferred fixed structures are limbal vessels. The pupil is dilated if necessary to visualize the IOL axis marks.
day of surgery, 1-2 days postoperative, 7-14 days postoperative, 30-60 days postoperative, 120-180 days postoperative
Other Halo and glare scores A Halo and Glare simulator software (Eyeland Design Network GmbH, Germany) will be used to assess the subjective perception of photic phenomena. The patients will be asked to adjust the halo and glare level in a simulated image to the amount they perceive of such photic phenomena. This test is performed pre- and postoperatively. The preoperative outcomes serve as a baseline measurement. Preoperative, 120-180 days postoperative, 330-420 days postoperative
Primary Primary Safety Endpoint: Rates of Adverse Events The objective is to compare the SPE (Safety and Performance Endpoints) rates of the investigational product to reference data stated in the according ISO standard for posterior intraocular lenses (EN ISO 11979-7:2018) based on minimum 100 subjects. 120-180 days postoperative
Primary Primary Performance Endpoint: Best Corrected Distance Visual Acuity The primary performance endpoint is to show non inferiority of Isatis TF compared to the monofocal comparator in terms of best corrected distance visual acuity (CDVA) by means of statistical significance. 120-180 days postoperative
Secondary Secondary Safety Endpoint: Best Corrected Distance Visual Acuity compared to historical data The objective is to compare best corrected distance visual acuities (CDVA) above defined thresholds of the investigational product to the normative data stated in the according ISO norm (EN ISO 11979-7:2018) for posterior chamber intraocular lenses. 120-180 days postoperative
Secondary Secondary Performance Endpoint: Distance Corrected Near Visual Acuity (DCNVA) Secondary performance endpoint is to show a statistically significant increase between pre-and postoperative findings on monocular Distance Corrected Near Visual Acuity (DCNVA) under photopic light conditions on the first implanted eye. 120-180 days postoperative
Secondary Secondary Performance Endpoint: Distance Corrected Intermediate Visual Acuity (DCIVA) Secondary performance endpoint is to show a statistically significant increase between pre-and postoperative findings on monocular Distance Corrected Intermediate Visual Acuity (DCIVA) under photopic light conditions on the first implanted eye. 120-180 days postoperative
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A