Cataract Clinical Trial
Official title:
Development of a Medical Device Based on Ultrasounds for Objective Cataract Characterization and Optimal Phacoemulsification Energy Evaluation
This study aims to assess the performance of an ultrasonic system for automatic classification of cataract type and severity, as well as the estimation of the optimal phacoemulsification energy. Ultrasonic signals from the lens will be acquired with the Experimental Medical Device (ESUS) in participants with cataract, and in healthy subjects (control). The proposed technique may represent an important advance in cataract treatment. The quantitative and automatic classification of cataract type and severity, and the estimation of the optimal phacoemulsification energy is may represent a valuable tool for surgical planning, reducing complications associated to excessive levels of phacoemulsification energy, as well as the times spent on surgeries. This device may be relevant not only for patients, but also for public health systems, reducing waiting lists and associated costs.
This is a prospective, pivotal, non-blinded study. Fifty (50) participants will be recruited at the Coimbra Surgical Center of Portugal. The study will be conducted on subjects with age-related cataract, and on healthy subjects as control group. Since this is a pilot study, no sample size estimation has been implemented. The statistical power will be determined at the end of the study. Only per-protocol participants will be considered on statistical analysis. Procedures involved. The ultrasonic system (Experimental Medical Device - ESUS) works in A-scan mode, with an acoustic working frequency of 20 MHz. From the ultrasonic signals backscattered from the lenses, acoustic parameters will be extracted, and used for automatic algorithms implementation. This study will be implemented once. Slit lamp with LOCS III classification will be used as comparator. Contrast sensitivity test results will be used for incipient cataract detection, where slit lamp may present some limitations. Optical coherence tomography and specular microscopy will help on detecting postoperative complications; other complications identified by the physician will be also considered. Surgical parameters as phacoemulsification energy and surgical time will help on phacoemulsification energy evaluation. Safety assessment. The system uses an ophthalmic probe. There are not anticipated adverse events related to the procedures involved in the use of the ultrasonic system, or any other procedure in the protocol. The safety conditions will be monitored through the occurrence of unanticipated adverse events or serious adverse events. If these situations occur, the event will be reported to the competent authorities (in agreement with the current regulation) and the corrective actions will be implemented. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |