Clinical Trials Logo

Clinical Trial Summary

The AssiAnchor 2 is a fixation ophthalmic device. The device is manufactured by Hanita Lenses from PMMA material which is being used for the production of Intra-ocular lenses. The device is intended for patients requiring capsule centration to clip the anterior lens capsule between the arms of the device and secure it to the scleral wall.


Clinical Trial Description

Intended Use: The AssiAnchor is a device which is intended to be implanted permanently in the posterior chamber of the eye for fixation of subluxated capsule. Study Objectives: The primary aim of this study is to assess the safety and performance of the new AssiAnchor. Safety will be assessed by evaluating the rate of adverse events and adverse device effects occurred throughout the study period. Study population: Men and women diagnosed with subluxated capsular bag that require lens removal surgery or in malpositioned pseudophakia that meet the inclusion/exclusion criteria and provide written informed consent will be enrolled in the study. Enrollment: A total of 10 subjects will be enrolled. Investigational sites: One (1) center will participate in this study. Duration of Subject participation: Completion of active enrolment is anticipated to last approximately 12 months. The objectives of this study will be achieved when the final study subject has completed 3 months follow-up. Primary Safety Endpoint : - Ease of implantation. - Stability of device within the eye Secondary Performance Endpoints -: IOL stability, centration and tilt, visual acuity Study Group: A single study group. This is a single arm design; there is no control device in this study. Key Inclusion Criteria: Subject requires capsule centration. Subject is between 18 and 100 years of age Subject understands the study requirements and the treatment procedures and provides written Informed Consent before any study-specific tests or procedures are performed Key Exclusion Criteria: Subject is diagnosed with active anterior segment intraocular inflammation Subject is obligated to previous participation in another study with any investigational drug or device within the past 30 days Subject is pregnant Visits & Procedures Pre-operative visit: 0-1 month prior the implantation procedure. The visit will include subject's qualification assessment for inclusion/exclusion criteria as described above. Informed consent must be signed. Complete anamnesis will be taken including subject's medical complaints, medical history, medication use and ophthalmic examinations, family history and any detail relevant to the cause of lens malposition Surgical procedure: Procedure will be performed under anesthesia (at physician discretion) and the modified AssiAnchor will be implanted. Follow-up: All subjects will have regularly follow-up visits up to 3 months post-implantation. All postoperative visits will include a complete ophthalmic examinations, medications used and recording of adverse events. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03455114
Study type Interventional
Source Hanita Lenses
Contact
Status Completed
Phase N/A
Start date March 24, 2018
Completion date June 9, 2021

See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A