Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT03320473
Other study ID # IC-8 302 KAMR
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date December 5, 2017
Est. completion date June 20, 2022

Study information

Verified date May 2023
Source AcuFocus, Inc.
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

A. The primary purpose of the study is to evaluate outcomes of aphakic eyes implanted with the IC-8 IOL following cataract removal in prior inlay patients after KAMRA inlay removal. B. The secondary purpose of the study is to determine whether there are any changes in biometry measurements before and after the inlay removal and how the changes affect the calculated IOL power.


Description:

This will be a prospective study in which no more than 20 subjects will be implanted with IC-8 IOL following the removal of the KAMRA inlay. The refractive target of the IC-8 eye will be -0.75 D MRSE. Subjects will be screened for eligibility and consented before enrolled. Following enrollment, the inlay will be removed, and the eye will be monitored for corneal and refractive stability before the implantation of the IC-8 IOL. Corneal stability is defined as keratometry readings in each meridian within ± 0.50 D, and/or the stability of the corneal topography as determined by the principal investigator, over two consecutive visits at least two weeks apart. Refractive stability is defined as manifest refractive sphere and cylinder measurements that are each within ± 0.50 D over two consecutive visits at least two weeks apart, or based on investigator judgment. When corneal and refractive stability are achieved, the IC-8 IOL will be implanted following cataract extraction by phacoemulsification.


Recruitment information / eligibility

Status Completed
Enrollment 29
Est. completion date June 20, 2022
Est. primary completion date June 20, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 45 Years and older
Eligibility Inclusion Criteria: i. Subjects must sign and be given a copy of the informed consent form. ii. Subjects with BCDVA of 20/40 or worse, or significant visual symptoms/complaints as a result of cataract in the study eye. iii. Subjects must be > 45 years of age at the time of screening. iv. Subjects must be willing and able to return for scheduled follow up examinations for 12 months after surgery. v. Subjects who underwent uneventful KAMRA inlay implantation and who currently still have the inlay in the eye. vi. Potential visual acuity following cataract removal and IOL implantation projected to be 0.8 or better (Snellen 20/25) as determined by diagnostic testing or investigator's medical judgment. Exclusion Criteria: i. Patients who had any type of intraocular surgery or refractive surgery (with the exception of KAMRA inlay implantation). ii. Requiring an intraocular lens outside the available power range of +15.5 to +27.5 diopters. iii. Pharmacologically dilated pupil size less than 6 mm or the presence of any pupil abnormalities (aniridia, non-reactive, fixed, or abnormally shaped pupils) or marked microphthalmos. iv. Preoperative corneal astigmatism > 1.5 diopters (as determined by corneal topography or keratometry in either eye) or irregular corneal astigmatism. v. Corneal abnormalities such as stromal, epithelial or endothelial dystrophies, or diagnosed degenerative visual disorders (e.g., macular degeneration or other retinal disorders) that are predicted to cause visual acuity losses to a level of 0.8 or worse during the study. vi. Active or recurrent anterior segment pathology (chronic uveitis, iritis, iridocyclitis, rubeosis iridis, etc.). vii. Glaucoma suspect, uncontrolled ocular hypertension, or history of glaucomatous changes in the retina or visual field. viii. Subjects with uncontrolled systemic disease. ix. Subjects with previous retinal pathology in either eye.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
IC-8 IOL
The AcuFocus IC-8 intraocular lens (IC-8 IOL) is a one-piece hydrophobic acrylic posterior chamber IOL into which a circular mask with a small 1.36 mm central aperture has been embedded. The IOL mask works by extending the depth of focus and its design is based on the KAMRA corneal inlay, which operates under the principle of small aperture optics.

Locations

Country Name City State
Philippines Asian Eye Institute Makati City

Sponsors (1)

Lead Sponsor Collaborator
AcuFocus, Inc.

Country where clinical trial is conducted

Philippines, 

Outcome

Type Measure Description Time frame Safety issue
Primary BCDVA Mean monocular best-corrected distance visual acuity at three months is at least 0.3 logMAR 3 months
Secondary UCNVA b.1. Mean monocular uncorrected near visual acuity (UCNVA) at 40 cm at 3 months is at least 0.3 logMAR. 3 months
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A