Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT02176343
Other study ID # C-14-005
Secondary ID
Status Completed
Phase N/A
First received
Last updated
Start date July 21, 2014
Est. completion date August 22, 2014

Study information

Verified date May 2017
Source Alcon Research
Contact n/a
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

The purpose of this study is to characterize the safety and effectiveness of the ACRYSOF IQ ReSTOR +2.5 diopter (D) Multifocal Toric Intraocular Lens (IOL) in subjects at least 3 months and no more than 14 months after IOL implantation.


Description:

This is a retrospective and prospective clinical study comprised of a retrospective chart review for preoperative, surgical and early postoperative data, and a prospective postoperative visit conducted at least 3 months but not more than 14 months after IOL implantation.


Recruitment information / eligibility

Status Completed
Enrollment 37
Est. completion date August 22, 2014
Est. primary completion date August 22, 2014
Accepts healthy volunteers No
Gender All
Age group 21 Years and older
Eligibility Inclusion Criteria:

- Must sign an informed consent form and be willing to come in for a visit at least 3 months and not more than 14 months after IOL implantation with the AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL (Models SV25T2, SV25T3, SV25T4 and SV25T5);

- Must be implanted with the correct lens based on preoperative corneal astigmatism as specified in the protocol;

- Must complete a visit within 10 days after IOL implantation;

- Successful capsular bag implantation with no surgical complications;

- Other protocol-specified inclusion criteria may apply.

Exclusion Criteria:

- IOL implanted prior to the AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL;

- Ocular or intraocular infection or inflammation at the time of the preoperative visit;

- Any ocular surgery or intraocular laser procedure at or prior to the surgical visit;

- Any conditions affecting the cornea (eg. corneal dystrophy, severe dry eye) at the preoperative visit;

- Retinal conditions (e.g. degenerative retinal conditions, history of retinal detachment, diabetic retinopathy) at the preoperative visit;

- Known history of Type 1 or 2 diabetes for more than 5 years;

- Any ocular or systemic co-morbidity at the preoperative visit;

- Pregnant at the preoperative visit or at the time of Postoperative Visit 2;

- Preoperative corneal astigmatism = 0.50 D;

- Participation in another clinical study at the preoperative visit or at the time of the final study visit;

- Other protocol-specified exclusion criteria may apply.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
AcrySof® IQ ReSTOR® +2.5 D Multifocal Toric IOL
Multifocal IOL with extended secondary focal point and astigmatism correction implanted for long-term use over the lifetime of the cataract patient

Locations

Country Name City State
n/a

Sponsors (1)

Lead Sponsor Collaborator
Alcon Research

Outcome

Type Measure Description Time frame Safety issue
Primary Mean Percent Reduction in Cylinder Manifest refraction cylinder was measured monocularly (each eye separately) with best correction (phoropter or trial lenses) under photopic (well-lit) lighting conditions using a 100% contrast ETDRS chart at 4 meters (m) from the subject. Percent reduction in cylinder was calculated as the difference between the postoperative magnitude of manifest refractive cylinder and the preoperative magnitude of keratometric cylinder divided by the intended reduction in cylinder [defined as the difference between the intended (from toric calculator) magnitude of the postoperative manifest refractive cylinder and the preoperative keratometric cylinder], multiplied by 100%. One eye (primary eye) contributed to the analysis. Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)
Primary Percentage of Subjects With Manifest Refraction Cylinder = 0.50 D Manifest refraction cylinder was measured monocularly with best correction under photopic lighting conditions using a 100% contrast ETDRS chart at 4 m from the subject. One eye (primary eye) contributed to the analysis. Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)
Primary Percentage of Subjects (With Preoperative Astigmatism > 1.00 D) With Manifest Refraction Cylinder = 1.00 D Manifest refraction cylinder was measured monocularly with best correction under photopic lighting conditions using a 100% contrast ETDRS chart at 4 m from the subject. One eye (primary eye) contributed to the analysis. Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)
Primary Mean Uncorrected Distance Visual Acuity Visual Acuity (VA) was tested monocularly without visual correction under photopic (well-lit) conditions using a 100% contrast ETDRS chart positioned 4 m from the subject. A +0.25 D spherical power additional lens was used to correct for optical infinity. VA was measured in logMAR (logarithm of the minimum angle of resolution), with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. One eye (primary eye) contributed to the analysis. Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)
Primary Mean Uncorrected Near Visual Acuity VA was tested monocularly without visual correction under photopic lighting conditions using a 100% contrast near ETDRS chart set at 40 cm on the nearpoint rod of the phoropter. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. One eye (primary eye) contributed to the analysis. Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)
Primary Mean Uncorrected Intermediate Visual Acuity VA was tested monocularly without visual correction under photopic lighting conditions using a 100% contrast near ETDRS chart set at 53 cm on the nearpoint rod of the phoropter. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. One eye (primary eye) contributed to the analysis. Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)
Primary Mean Best Corrected Distance Visual Acuity (BCDVA) VA was tested monocularly with best correction under photopic lighting conditions using a 100% contrast ETDRS chart at 4 m away from the subject. VA was measured in logMAR, with 0.1 logMAR increment corresponding to 5 letters, or 1 line, on an ETDRS chart. A lower numeric value represents better visual acuity. One eye (primary eye) contributed to the analysis. Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)
Primary Mean IOL Rotation Lens axis orientation (position of the lens within the capsular bag) as indicated by indentations on the IOL was assessed during slit lamp examination. IOL rotation (the difference between the achieved lens axis orientation at visit and achieved axis placement at surgery) was measured in degrees. One eye (primary eye) contributed to the analysis. Preoperative and Postoperative Visit (3 to 14 months after IOL implantation)
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A