Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT01305616
Other study ID # 975
Secondary ID
Status Completed
Phase N/A
First received February 28, 2011
Last updated March 25, 2011
Start date May 2008
Est. completion date January 2010

Study information

Verified date March 2008
Source Rassoul Akram Hospital
Contact n/a
Is FDA regulated No
Health authority Iran: Ethics Committee
Study type Interventional

Clinical Trial Summary

To investigate the effect of yellow-tinted IOLs on the Short Wave-length Automated Perimetry (SWAP) and Standard Automated Perimetry (SAP) in patients with and without glaucoma.


Description:

Glaucoma is mostly a disease of old people and is highly accompanied with cataract.Some of these patients may need to perform cataract surgery during the course of glaucoma. But in glaucoma patients, the effect of cataract surgery and/or type of implanted intraocular lens (IOL) on the results of specific visual field tests, like SWAP, is still not well studied.From the past decade, various yellow-tinted IOLs with the speculation of protecting the retinal photoreceptors and decreasing the incidence of age-related macular degeneration have been introduced.These blue-light-filtering IOLs contain a yellow chromophore that filters ultra violet (UV) and a larger part of the high-energetic visible blue-light between 380 and 500 nm. Based on previous studies yellow-tinted IOLs decrease the amount of light transmission to the retina which may theoretically affect perimetry results. This might be even more important in patients with glaucoma where the sensitivity of test locations has decreased per se.

Since early diagnosis of glaucoma and its progression is highly dependent on visual field results, it is important to evaluate the effect of these IOLs on perimetry, particularly on SWAP, in which the blue-light-filtering IOLs might interfere with its findings.


Recruitment information / eligibility

Status Completed
Enrollment 34
Est. completion date January 2010
Est. primary completion date November 2009
Accepts healthy volunteers No
Gender Both
Age group 40 Years to 80 Years
Eligibility Inclusion Criteria:

- In group 1, visually significant cataract associated with well controlled mild to moderate open angle glaucoma (intraocular pressure < 18 with maximally-tolerated medical treatment)and no history of previous intraocular surgeries

- In group 2- Normal ophthalmic examination other than visually significant cataract

Exclusion Criteria:

- Diabetes mellitus

- neurological disease which may affect the results of visual field

- known systemic medication with involvement on visual field

- spherical refractive error less than -5 and more than +5 diopter

- cylindrical correction more than 3 diopter

Study Design

Allocation: Non-Randomized, Intervention Model: Parallel Assignment, Masking: Open Label


Related Conditions & MeSH terms


Intervention

Procedure:
Phacoemulsification with yellow-tinted intraocular lens
Phacoemulsification is a kind of cataract surgery using ultrasound machine. Yellow-tinted intraocular lens are a sort of lens with the ability to filter blue and ultraviolet spectrum of light (380-500 nanometer)
Phacoemulsification with yellow-tinted intraocular lens
Phacoemulsification is a kind of cataract surgery using ultrasound machine. Yellow-tinted intraocular lens are a sort of lens with the ability to filter blue and ultraviolet spectrum of light.

Locations

Country Name City State
Iran, Islamic Republic of Rassoul Akram Hospital Tehran

Sponsors (1)

Lead Sponsor Collaborator
Rassoul Akram Hospital

Country where clinical trial is conducted

Iran, Islamic Republic of, 

References & Publications (2)

Jang SY, Ohn YH, Kim SW. Effect of yellow-tinted intraocular lenses on short-wavelength automated perimetry. Am J Ophthalmol. 2010 Aug;150(2):243-247.e1. doi: 10.1016/j.ajo.2010.02.023. — View Citation

Kara-Júnior N, Jardim JL, de Oliveira Leme E, Dall'Col M, Susanna R Jr. Effect of the AcrySof Natural intraocular lens on blue-yellow perimetry. J Cataract Refract Surg. 2006 Aug;32(8):1328-30. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Mean deviation changes on SAP and SWAP before and after surgery Mean deviation(decibel) which is the average change of visual field points from normal age- matched group ,was obtained from visual field print out. Its value is from 0 to -30 decibels where the lower values means the point is more damaged. 2.5months No
Secondary Visual Acuity changes measured with Snellen chart and Pattern Standard Deviation (PSD)and Foveal threshold (FT) changes on SAP and SWAP. visual acuity measurements were converted to logarithm minimum angle of resolution (logMAR).PSD (decibel)and FT(decibel) were obtained from the Humphrey visual field machine printout. 2.5 months No
See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A