Clinical Trials Logo

Clinical Trial Summary

This study is to compare intraindividually the functional vision provided by two different posterior chamber intraocular lenses: AMO Tecnis Z9000 and Alcon SA60AT Acrysoft. To see if the aspherical intraocular lenses provide better functional vision than traditional spherical intraocular lenses.


Clinical Trial Description

In this prospective study, 20 patients with bilateral catarct presenting for cataract surgery are randomly assigned to recieve an aspherical intraocular lens(AMO Tecnis Z9000) in one eye and a spherical intraocular lens(Alcon SA60AT Acrysof)in the other. All surgeries are performed by one experienced surgeon(Fung-Rong Hu,MD)with clear cornea small incision phacoemulsification and in-the-bag posterior chamber intraocular implantation.

The patients are followed for 3 months, and postoperative contrast sensitivity, contrast acuity, corneal & total ocular high-ordered aberrations are measured and compared intraidividually between two different IOL groups.

Outcome Measurement:

1. Contrast sensitivity testing: measured with spectacle correction for the target distance of three meters using wall-mounted FACT sine-wave grating chart with nine levels of contrast.The graphic contrast sensitivity is recorded as a log functional units on the y-axis and displayed for five spatial frequency targets (1.5, 3, 6, 12, 18 cycles per degree (cpd))on x- axis.

2. Contrast acuity testing: measured with spectacle correction for the target distance of three meters using logMAR letter chart(Precision Vision®)represented on a wall-mounted illuminator cabinet.Two types of contrast charts are used, high contrast(Cat.No.2103 SLOAN translucent chart)and low contrast(Cat.No.2132 10% SLOAN translucent chart),and are tested under both photopic and mesopic conditions.

3. Pupil diameters: measured by Colvard infrared pupillometer (Oasis. Medical, Glendora, CA, USA )under both photopic and mesopic luminance levels.

4. Corneal aberration analysis: performed with TMS-4 (Tomey, Japan).The corneal HOAs are described with Zernike polynomials of 3rd-to 5th- order root-mean-square(RMS)of central 6mm diameter using VOLPro 6.89 software(Fa. Sarver and Associates, Carbondale. Ill, USA).

5. Total ocular aberration analysis: performed with a Hartmann-Shack aberrometer(Zywave, Bausch & Lomb Inc., Rochester, New. York)under maximal mydriasis with Mydrin-P(phenylephrine hydrochloride 0.5% and tropicamide 0.5%, Santen).The wavefront errors were described using Zernike polynomials RMS for total HOA at pupil diameter of 5 mm and 6 mm, primary spherical (Z 4,0) and 3rd-to 5th-order aberration at pupil diameter of 6 mm.

Data Analysis:

- Mann-Whitney U matched-paired test was used with STATA software

- P values of 0.05 or less were considered statistically significant ;


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Double Blind (Subject, Outcomes Assessor), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00459303
Study type Interventional
Source National Taiwan University Hospital
Contact
Status Completed
Phase Phase 4
Start date October 2005
Completion date December 2007

See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A