Cataract Clinical Trial
Official title:
Determination of Surgical Efficacy and Most Efficient Surgical Parameters for Use With the 2.2, 2.8, and 3.0mm Phacoemulsification Sleeves Used With the Alcon Infinity 1.1mm ABS Flared Tip
Incision size in cataract surgery is related to induced surgical astigmatism, chamber stability, and surgical efficiency. Sleeves of different diameters change the size of the surgical incision and amount of fluid allowed into the eye during the surgical procedure for a given set of surgical parameters. Optimization of surgical parameters requires review of surgical efficiency including: fluid usage, energy usage, and total surgical time. With optimized surgical parameters recommendations can be made to increase the efficiency and safety of cataract surgery.
No scientific data has been presented comparing the surgical efficiency of the 2.2, 2.8, and 3.0 mm diameter phacoemulsification sleeves for the Alcon Infinity 1.1 mm flare abs tip or the changes in surgical parameters which optimize their performance. Fifty patients per sleeve group will undergo standard cataract extraction with documentation of surgical parameters used for each group. The goal of the study is to determine the most efficient surgical settings for each sleeve diameter and determine statistically the surgical parameters which optimize the use of each phacoemulsification sleeve. Purpose: The goal of the study is to determine the most efficient surgical settings for each sleeve diameter and determine statistically the surgical parameters which optimize the use of each phacoemulsification sleeve. Design: The study is designed to allow for scientific evaluation and publication of efficiency parameters using phacoemulsification sleeves of 2.2, 2.8, and 3.0 mm. The proposed study is a prospective nonrandomized clinical investigation of 50 patients per sleeve group. Methods: Data gathered at the time of surgery will include standard surgical parameters including: Total surgical time, total phacoemulsification/torsional time/power, total volume of infusion fluid, aspiration level, and vacuum level. Post-operative data will include: Post-op day one and week three corneal clarity (clear, would edema, central edema), anterior chamber cell seen in a 2mm 16x magnified slit-lamp biomicroscopic view focused in the aqueous humor (Grade 0 = 0 cells, 1 = up to 10 cells, 2 = 10 to 20 cells, 3 = 20 to 30 cells, 4 = too numerous to count), and uncorrected and/or best corrected visual acuity. ;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT04685538 -
Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification.
|
Phase 3 | |
| Recruiting |
NCT06060041 -
IC-8 Apthera IOL New Enrollment Post Approval Study
|
||
| Recruiting |
NCT05518539 -
Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
|
||
| Recruiting |
NCT05271942 -
Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods
|
N/A | |
| Active, not recruiting |
NCT04778501 -
PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia
|
N/A | |
| Completed |
NCT05062564 -
Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye
|
N/A | |
| Completed |
NCT03751033 -
Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings
|
N/A | |
| Completed |
NCT02529488 -
Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00
|
N/A | |
| Completed |
NCT04539548 -
A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract
|
Phase 3 | |
| Completed |
NCT03740659 -
Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery
|
Phase 2 | |
| Completed |
NCT03494257 -
Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification
|
N/A | |
| Completed |
NCT05119127 -
Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome.
|
N/A | |
| Active, not recruiting |
NCT04271709 -
Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT)
|
N/A | |
| Recruiting |
NCT03713268 -
Intraoperative OCT Guidance of Intraocular Surgery II
|
||
| Completed |
NCT03739528 -
Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery
|
Phase 3 | |
| Completed |
NCT02888210 -
A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery
|
Phase 3 | |
| Completed |
NCT03356847 -
Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery
|
N/A | |
| Completed |
NCT04332640 -
Clinical Evaluation of the Next Generation Phaco System
|
N/A | |
| Recruiting |
NCT03638726 -
Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification
|
Phase 4 | |
| Completed |
NCT03050697 -
Evaluation of the Safety and Performance of the HARMONI® Toric Lens
|
N/A |