Clinical Trials Logo

Clinical Trial Summary

The introduction of presbyopia-correcting intraocular lenses (PC-IOLs) has provided cataract and refractive surgeons the ability to provide patients with a wider range of visual success and spectacle independence post-cataract surgery.Multifocal (MFIOL) IOLs have the ability to provide near and distance vision, and in the case of trifocal IOLs, near, intermediate and distance. Despite the significant technological evolution of MFIOL's, the potential for visual disturbances, such as glare, halos and starbursts still exists-and in much greater frequency compared to their monofocal counterparts. Extended depth of focus (EDOF) IOLs aim to provide patients with a functional range of vision, with a similar visual disturbance profile to a monofocal lens. In this way, this subset of PC-IOL's can offer patients some degree of spectacle independence, with a significantly lower incidence of visual disturbances. The Vivity Extended Vision IOL is the first of its kind to offer Wavefront Stretching technology, providing patients with an excellent extended range of vision from intermediate to distance, as well as some functional near vision. Prior studies have demonstrated very good vision in both bright and dim lighting conditions, as well as a high degree of spectacle independence with the Vivity IOL, as compared to a monofocal IOL. Studies evaluating the ability of the Vivity IOL to provide a significant impact on patient lifestyle (e.g. patient independence from spectacles for most activities with a low rate of visual disturbances) in the United States in a 'real-world' setting have yet to be performed. In addition, influence of pre-and-perioperative variables such as sex, age, prior refractive surgery, IOL formula used, axial length, astigmatism, use of intraoperative aberrometry, femtosecond laser and pupillary expansion devices has yet to be evaluated on the postoperative success of this IOL. This study will be comprised of patients with visually significant cataracts who will undergo cataract extraction with implantation of the spherical and/or toric models of the Vivity Extended Vision (Alcon, Fort Worth TX) intraocular lens. Upon decision of the patient and surgeon to undergo surgery, patients will be offered the option to enroll in this observational study.


Clinical Trial Description

Presbyopia-correcting intraocular lenses (PC-IOLs) provide cataract and refractive surgeons with an effective treatment option for presbyopia, allowing patients increased spectacle independence post-cataract surgery. Different IOL designs have been developed based on differing optical principals, such as diffractive, refractive and extended depth of focus (EDOF) design. Most commercially available MFIOLs have two optical zones, one that provides distance vision, and the second that provides near vision (i.e. "bifocal IOLs"). Most recently, trifocal IOLs have been released, with the aim of providing a third (intermediate) focal point, and hence an extended range of vision in pseudophakic patients. While being able to provide patients with near, intermediate and distance vision, most MFIOL's carry the risk of increased visual disturbances, such as glare, starbursts, and halos, which for a small percentage of patients may become quite bothersome or even debilitating. Extended depth of focus (EDOF) IOLs aim to provide an extended range of vision from intermediate to distance, with a similar visual disturbance profile to their monofocal counterparts. Prior to recent FDA approval, there was only one other EDOF IOL on the market in the US, which, although provides an extended visual range, still had a significant incidence of starbursts and visual disturbances in some patients. FDA approved in February 2020, the Vivity Extended Vision Lens has demonstrated the ability to provide patients with an extended range of vision, excellent contrast sensitivity and visual disturbance profile comparable to a monofocal IOL, as well as high rates of spectacle independence for most activities. The Vivity Extended Vision IOL (Alcon Laboratories, Fort Worth TX) is an EDOF IOL made of hydrophobic acrylic. This non-diffractive lens was designed to mitigate the effect of presbyopia by providing an extended depth of focus through patented Wavefront Shaping technology. In clinical trials, Vivity has demonstrated significantly better intermediate and near vision as compared to a monofocal IOL, as well as superior spectacle independence scores. Additionally, a validated questionnaire regarding visual disturbances showed the Vivity to have comparable rates of starburst, glare and halos to its monofocal counterpart. In an era where intermediate vision has become very important (e.g. using laptops, tablets, seeing the dashboard in a car), many patients express desire for visual correction at all possible focal points. Vivity appears to deliver this with minimal visual side effects-even less so as compared to other MFIOL's. This is a valuable aspect of Vivity; spectacle independence is an important factor for many patients-however if this is coupled with debilitating glare, haloes or other visual disturbances, dissatisfaction will ultimately result. Multiple studies have explored variables that may influence postoperative success of these MFIOLs, including the impact of dry eye, prior corneal refractive surgery, and proper preoperative consent/expectations. A study has yet to be performed evaluating not only preoperative factors, such as astigmatism, and prior corneal refractive surgery, but also perioperative and intraoperative factors that may also play a role in success of the Vivity IOL implant. In this prospective, nonrandomized "real-world" study, the impact of perioperative factors, such as IOL formulae used, use of femtosecond laser, use of intraoperative aberrometry, as well use of pupillary expansion devices on surgical success will be evaluated. Surgical success will be defined as uncorrected distance, intermediate and near visual acuity (UDVA, UIVA and UNVA, respectively) of 20/40 or better (both monocular and binocular) as well as high levels of patient satisfaction, which will be recorded with a Visual Disturbance Questionnaire, Spectacle Independence Questionnaire, and Visual Quality Questionnaire. Results will provide never-before-published data on important preoperative as well as perioperative factors that may influence success and patient satisfaction with Vivity IOL implantation ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04570579
Study type Observational
Source Sight Medical Doctors PLLC
Contact
Status Active, not recruiting
Phase
Start date October 14, 2020
Completion date April 30, 2024

See also
  Status Clinical Trial Phase
Completed NCT04685538 - Chloroprocaine 3% Gel Eye Drop as Topical Anestheticsin Phacoemulsification. Phase 3
Recruiting NCT06060041 - IC-8 Apthera IOL New Enrollment Post Approval Study
Recruiting NCT05518539 - Evaluation of Quality of Vision and Visual Outcomes With Bilateral Implantation of the Clareon PanOptix Intraocular Lens
Recruiting NCT05271942 - Tilt and Tumble vs Divide and Conquer - a Unique Comparison of the Two Cataract Surgery Methods N/A
Active, not recruiting NCT04778501 - PMCF Study on Monofocal Toric IOL (PODEYE TORIC) in Asia N/A
Completed NCT05062564 - Efficacy of LipiFlow in Patients Affected by Meibomian Gland Dysfunction in Reducing Post-cataract Surgery Dry Eye N/A
Completed NCT03751033 - Influence of DisCoVisc Ophthalmic Viscosurgical Device (OVD) on Intraoperative Aberrometry Readings N/A
Completed NCT02529488 - Investigation of AcrySof® IQ PanOptix™ Presbyopia-Correcting Intraocular Lens (IOL) Model TFNT00 N/A
Completed NCT04539548 - A Study Assessing the Safety and Efficacy of Dextenza® for the Treatment of Ocular Pain and Inflammation Following Surgery for Pediatric Cataract Phase 3
Completed NCT03740659 - Evaluation Of Aqueous Humor Of Levofloxacin-Dexamethasone Eye Drops And Of Its Components In Patients Undergoing Cataract Surgery Phase 2
Completed NCT03494257 - Effect of Fixed Brinzolamide-brimonidine Combination on Intraocular Pressure After Phacoemulsification N/A
Completed NCT05119127 - Rotational Stability of Acrysof IQ Vivity Extended Vision Toric IOL and Refractive Visual Outcome. N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03713268 - Intraoperative OCT Guidance of Intraocular Surgery II
Completed NCT03739528 - Levo-Dexa vs. Tobra+Dexa for Prevention and Treatment of Inflammation and Prevention of Infection in Cataract Surgery Phase 3
Completed NCT02888210 - A Study Assessing Safety and Efficacy of MD-15 Intraocular Lens in Patients With Aphakic Eye After Cataract Surgery Phase 3
Completed NCT03356847 - Evaluation of the Rotational Stability of the Monofocal SISA Implant Following Cataract Surgery N/A
Completed NCT04332640 - Clinical Evaluation of the Next Generation Phaco System N/A
Recruiting NCT03638726 - Subconjunctival Atropine and Intracameral Epinephrine for Pupil Dilation in Phacoemulsification Phase 4
Completed NCT03050697 - Evaluation of the Safety and Performance of the HARMONI® Toric Lens N/A