View clinical trials related to Cataract Senile.
Filter by:This will be a prospective observational, ethics committee approved study where patients undergoing routine cataract surgery will have bilateral implantation of the intraocular lens (LuxSmart, Bausch & Lomb). The device under investigation is CE-mark approved and commercially available. The device under investigation and all study products, including the devices used for the study examinations, will be used within the intended use specifications from the manufacturer. In addition, no invasive or other burdening examinations will occur for the patient. Investigator is accredited and experienced cataract surgeon and researchers who have been involved in similar studies in the past. The device under investigation LuxSmart (Bausch & Lomb) is a hydrophobic, acrylic copolymer containing UV absorber intraocular lens (IOL). The IOLs will be implanted as part of the routine cataract surgery on patients suffering from cataract development. In total 30 patients will be recruited for this first clinical experience and receive bilateral implantation of the LuxSmart. The maximum time between 1st and 2nd eye implantation is 30 days, some patients may receive bilateral implantation on the same day. However there will be a minimum of 1 week between the implantations in the first 10 patients.
Comparative safety study of intracameral levofloxacin versus moxifloxacin for postoperative infection prophylaxis
Since recently a second swept-source optical coherence tomography (ss-OCT) optical biometry device was launched (Anterion, Heidelberg Engineering). Aim of this study is a retrospective data collection of patients who were measured with both ss-OCT optical biometry devices and to assess the limits of agreement of the two devices. Retrospective comparison of two ss-OCT biometry devices concerning comparability of measurements of axial eye length, anterior chamber depth, lens thickness and keratometry.
This is to compare preoperative and postoperative binocular functional vision in patients with unilateral intraocular len(IOL) in one eye and mild cataract in the fellow eye.
Compare postoperative Subjective and objective visual quality and economic efficiency of different Intraocular Lens(IOLs) implantation designed for the correction of presbyopia.
Achieving high accuracy and precision in ocular biometry has become primordial for cataract surgery, due to the shift of cataract surgery from a rehabilitation procedure to a refractive one. Aim of this study is to determine the repeatability of ocular biometric parameters obtained using three biometry devices, two ss-OCT biometers and an OLCR device.
To investigate that VISTHESIA 1.5 is non-inferior to Provisc with regards to elevation in IOP greater than or equal to 30 mm Hg 6 ± 2 hours post-operatively as per methodology set out in EN ISO 15798:2013 (Primary Endpoint) To compare the changes in endothelial cell count and incidences of intraocular inflammation between VISTHESIA and Provisc as per methodology set out in EN ISO 15798:2013
With a poor red reflex, it is difficult to see the anterior capsule and continuous curvilinear capsulorhexis (CCC) margin, sometimes resulting in decentered CCC or radial tearing of the anterior capsule. In addition, other complications, such as rupture of the posterior capsule, dropping of the lens nucleus, or zonular dialysis, can occur during phacoemulsification because of poor visualization of the posterior capsule. These complications also increase the time of surgery and may affect the results of the vitrectomy.
Cataract surgery involves replacing milky lens with a plastic intraocular lens. This plastic lens can be either monofocal (fixates for distance or near without glasses), extended depth of focus (EDOF)(fixates for intermediate and distance vision only without glasses) or multifocal lenses (fixates for distance, intermediate and near vision without glasses). However, EDOF and multifocal lenses are known to produce glare and halos. Tecnis Eyhance (Johnson & Johnson, USA) is a monofocal IOL which give added intermediate vision without employing EDOF or multifocal technology and hence induces no glare and halos. Whereas monofocal IOLs such as RayOne do not give intermediate vision. The objective is to assess visual and optical performance of Tecnis Eyhance versus Rayner RayOne in a prospective, randomized, comparative bilateral study. The proposed study will be the first study comparing the new technology monofocal Eyhance with conventional RayOne Rayner lens to assess the added benefits of Eyhance technology at multiple visits until 3 months after the surgery. Patients attending the clinics with cataracts will be invited to participate in this randomised study. They will be randomised to receive either Eyhance or RayOne in both eyes through surgeries performed not more than 2 weeks apart. The patients will be followed up at 1 and 3 months in the research clinic to assess the uniocular and binocular vision, spectacle prescription, a simple non-invasive scan to look at any distortions in the optics of the eye (wavefront aberrometry) and questionnaire for assessing subjective outcomes, glare and halos.
This study evaluates and compares clinical outcomes of < 85 and ≥ 85 year old patients who underwent cataract surgeries.