Clinical Trials Logo

Cardiac Output, Low clinical trials

View clinical trials related to Cardiac Output, Low.

Filter by:
  • Completed  
  • Page 1 ·  Next »

NCT ID: NCT06326762 Completed - Cardiac Output, Low Clinical Trials

Gap CO2 in Septic Patient to Predict Cardiomyopathy Septic

Start date: January 1, 2023
Phase:
Study type: Observational

the investigators included 98 patients admitted for sepsis and septic shock (68.4% men, 31.6% women) with an average age of 60.42 years ± 15.13, ranging from 21 to 96 years. The average length of hospital stay was 7.53 days. The most noted medical histories were diabetes (38.8%), hypertension (28.6%), and renal insufficiency (17.1%). Regarding laboratory findings: the mean white blood cell count was 15,985.16 cells/mm³, the mean C-reactive protein (CRP) level was 227.69 mg/L, and the mean procalcitonin level was 50.43 µg/L. In terms of blood gas analysis: the mean lactate level was 3.67 mmol/L, and the mean PCO2 gap (DELTAPCO2) was 4.85. All our patients were continuously monitored by pulse wave analysis: the mean cardiac output was 5.69 L/min, and the mean cardiac index was 4.14 L/s/m² All our patients underwent an echocardiogram, which is a routine examination in our department and is performed at the patient's bedside. The average left ventricular ejection fraction (LVEF) was 51.73%, and the average subaortic peak velocity (ITV) was 14.66 cm. Subsequently. the investigators examined the clinical and paraclinical profile of patients with septic cardiomyopathy. the investigators identified 19 patients with this condition, while 79 patients did not exhibit cardiac involvement. The percentage was significantly higher in the population with cardiac involvement, accounting for 28.3%. Among the patients with cardiac involvement, 76.5% had a PCO2 gap (DELTAPCO2) ≥ 6 mmHg, a significantly reduced cardiac output with an average of 3.3 L/min, and a predominantly low cardiac index, with 64.3% having an index < 2.2 L/min/m². The mortality rate was significantly increased at 73.7%.

NCT ID: NCT05365113 Completed - Blood Pressure Clinical Trials

Comparison of Hemodynamic Effects of Two Modalities of Alveolar Recruitment Maneuvers in Major Abdominal Surgery Patients

CHARM-Bloc
Start date: March 9, 2022
Phase: N/A
Study type: Interventional

The objective of this study is to investigate the hemodynamic effects of two strategies of alveolar recruitment maneuver in patients undergoing major abdominal surgery in the operating room

NCT ID: NCT05101291 Completed - Anesthesia Clinical Trials

Fractional Spinal Anesthesia and Systemic Hemodynamics in Frail Elderly Hip Fracture Patients.

Start date: January 15, 2021
Phase: N/A
Study type: Interventional

Aging and frailty make the elderly patients susceptible to hypotension following spinal anaesthesia. The systemic haemodynamic effects of spinal anaesthesia are not well known. In this study, we examine the systemic haemodynamic effects of fractional spinal anaesthesia following intermittent microdosing of a local anesthetic and an opioid. We included 15 patients aged over 65 with considerable comorbidities, planned for emergency hip fracture repair. Patients received a spinal catheter and cardiac output monitoring using the LiDCOplus system. Invasive mean arterial pressure (MAP), cardiac index, systemic vascular resistance index, heart rate and stroke volume index were registered. Two doses of bupivacaine 2,25 mg and fentanyl 15µg were administered with 25 minutes in between. Hypotension was defined as a fall in MAP by >30% or a MAP <65 mmHg

NCT ID: NCT05070819 Completed - Cardiac Disease Clinical Trials

Atrial Natriuretic Peptide in Assessing Fluid Status

Start date: September 23, 2021
Phase: N/A
Study type: Interventional

Biomarkers can play a significant role in fluid status assessment intraoperatively.

NCT ID: NCT04955184 Completed - Clinical trials for Congestive Heart Failure

Comparing Cardiac Output Measurements Using a Wearable, Wireless, Non-invasive PPG-Based Device to a Swan Ganz Catheter

Start date: October 10, 2021
Phase:
Study type: Observational

Invasive pulmonary capillary wedge pressure measurements using a Swan-Ganz catheter (SGC) is considered the gold standard for cardiac output (CO) monitoring. In this prospective study, we will compare CO measurements between a PPG-based wearable monitor and a SGC in ambulatory CHF patients.

NCT ID: NCT04825015 Completed - Clinical trials for Liver Transplant; Complications

Hemodynamic Monitoring in Liver Transplant With VEnaRt Cardiac Output Versus Swan-Ganz Catheter (VERO Study)

VERO
Start date: April 1, 2021
Phase:
Study type: Observational

The Swan-Ganz catheter is the gold standard to measure cardiac output during liver transplantation surgery. This is an invasive hemodynamic monitoring system. The VenArt Cardiac Output (Mespere LifeSciences, Waterloo, Canada) is a new, innovative and non-invasive device that permits hemodynamic monitoring. With a software based on Fick's principle it is able to calculate cardiac output, cardiac index and continuous cardiac output. The hypothesis of this study is to investigate the precision and accuracy of this method versus the standard of care during liver transplantation.

NCT ID: NCT04641949 Completed - Analgesia Clinical Trials

Methoxyflurane and Fentanyl in LBNP

Start date: November 18, 2020
Phase: Phase 4
Study type: Interventional

The study is a single-centre, placebo-controlled, crossover study on healthy volunteers aiming to explore non-inferiority of methoxyflurane and fentanyl compared to placebo on the tolerance to hypovolemia.

NCT ID: NCT04593797 Completed - Cardiac Output, Low Clinical Trials

Echo FLOW Versus (Non-)Invasive Haemodynamics

EFLOW
Start date: April 19, 2018
Phase:
Study type: Observational

Rationale: Diligent fluid management is instrumental to improve postoperative outcome, cost and quality of care. Objective: To determine the accuracy of brachial, femoral and carotid blood flow measurement with ultrasound compared to intermittent transpulmonary thermodilution cardiac output measurement, invasive and non-invasive pulse-contour analysis. Study design: Observational study - Prospective clinical non-intervention measurement study. Study population: Adult ASA 1-2 patients, scheduled for open upper GI surgery Intervention (if applicable): Not applicable. We will perform non-invasive ultrasound measurements of the femoral, carotid and brachial blood flow right before induction and under anaesthesia. Main study parameters/endpoints: Femoral, carotid and brachial blood flow determined by ultrasound and blood flow variation and the accuracy compared to transpulmonary thermodilution cardiac output, stroke volume variation, and pulse-contour analysis derived cardiac output (invasive or non-invasive) at the following time points during surgery; (limited for femoral site as it cannot be measured during surgery): (1) before induction of anaesthesia, (2) after induction, (3) 15 minutes after start of surgery, (4) before and (5) after (1-2 minutes) a fluid bolus, (6) before and (7) after start of vasopressors, (8) before and (9) after Trendelenburg position and (10) after surgery before end of anaesthesia (figure 1). A fluid bolus will be performed as part of standard care (goal-directed fluid therapy). The vasopressor and Trendelenburg position time points are optional measurements. We will also measure (continuous) invasive femoral blood pressure (SBP, DBP, MAP), non-invasive blood pressure, SVV, central venous pressure (when available), heart rate, SpO2, PFI, etCO2.

NCT ID: NCT04358822 Completed - Cardiac Output, Low Clinical Trials

Hemodynamic Effects of Delayed Umbilical Cord Clamping in Full-term Newborns

Start date: January 21, 2020
Phase: N/A
Study type: Interventional

The sequence of events at the time of delivery includes delivery of the infant, clamping of the umbilical cord, and lastly delivery of the placenta. There are some benefits for delayed cord clamping. This study aims to compare the effects of two different duration of delayed cord clamping. Infants will be randomized into two groups based on the duration of delayed cord clamping: 30 seconds vs 120 seconds. Different hemodynamic effects will be measured in each group at different time intervals. The hypothesis of the study is that delayed cord clamping for 120 seconds is associated with better cardiac output and with other hemodynamic advantages.

NCT ID: NCT04184245 Completed - Preterm Birth Clinical Trials

Hemodynamic Responses to Cardio-respiratory Events in Preterm Infants

Start date: February 22, 2018
Phase:
Study type: Observational

Intermittent episodes of hypoxemia and/or bradycardia, also defined as cardio-respiratory events (CRE) are very frequent in preterm infants and may result in transient hypoxia and hypoperfusion of target organs, with possible clinical implications. The hemodynamic instability that characterizes the first 72 hours of life, also called as transitional period, place preterm infants at high risk of complications and may contribute to enhance fluctuations in end-organ perfusion and oxygenation induced by CRE. In this study we aimed to explore cardiovascular and cerebrovascular changes determined by different CRE types in preterm infants during the transitional period.