Clinical Trials Logo

Clinical Trial Summary

Atrial fibrillation (AF) stands as the most common type of cardiac arrhythmia. The frequency of AF in the overall population is 1-2%, with the incidence rate increasing with age from 0.5% in the 40-50 years old to 5-15% in those aged 80. [According to current recommendations for catheter ablation (CA) in patients with AF, the isolation of the pulmonary veins (PV) is a pivotal aspect of treating this arrhythmia. Despite recent advancements, 20-45% of patients experience recurrences after PV isolation. According to the study by Wasmer K. et al., it was demonstrated that most patients with recurrent AF after PVI showed at least one reconnected vein during redo procedures. The primary cause of recurrences is the restoration of conduction, attributed to endurable isolation (non-transmural, intermittent RF). Numerous approaches have been presented to enhance the outcomes of surgical treatment for AF, such as the CLOSE protocol and Ablation Index (AI) . CLOSE protocol represents an approach aimed at isolating the PV ostia through precise continuous (distance between points ≤ 6 mm) radiofrequency intervention, achieving target ablation index values of ≥ 400au for the posterior wall and ≥ 500au for the anterior wall. The Ablation Index is a marker of quality lesion formation, providing a visual representation of the lesion based on the integration of power, contact force, and time parameters, which is displayed on the CARTO® 3 system (Biosense Webster). Throughout radiofrequency ablation, electromagnetic energy undergoes conversion into thermal energy, leading to tissue damage and temperature elevation. The temperature elevation process encompasses two stages: resistive heating, impacting surface tissues (1-2mm), and conductive heating, which facilitates the transfer of heat from surface tissues to underlying tissues. In the presence of good catheter-endocardium contact (25%), only 9% of the power is effectively delivered to the endocardium. For instance, at a power level of 30 watts and optimal contact (25%) with the endocardium, merely 2.7 watts are transferred to the endocardial tissue. When applying 30 watts of power for 30 seconds, a total energy delivery of 900 joules occurs, with only 90 joules being imparted to the endocardium. Similarly, at 50 watts for 10 seconds, only 45 joules of energy are transmitted to the endocardium. When operating at 10 watts, the catheter temperature elevates by 13°C. Consequently, at 30 watts, the temperature reaches 39°C, and at 50 watts, it rises to 65°C. The formation of an irreversible lesion necessitates a temperature exceeding 50°C. During standard radiofrequency ablation (RFA) procedures with power settings ranging from 20 to 45 watts and a duration of 20 to 60 seconds, the formation of ablation points predominantly occurs during the conductive heating phase. High power short duration ablation (HPSD) is an approach that reduces the conductive heating phase while increasing the resistive heating phase. This results in an expanded area of lesion, facilitating the formation of transmural lesions in the atrial myocardium with irreversible tissue damage and reduced risk to surrounding structures, such as thermal injury to the esophagus. The strategy of HPSD ablation was developed to overcome limitations of the traditional approach. However, much remains unknown regarding the safety and effectiveness of this approach. Additionally, the question for the optimal interventional treatment method for atrial fibrillation (AF) and the selection of the optimal RF energy for pulmonary vein isolation still require confirmation. This forms the basis for our research objective.


Clinical Trial Description

The research was a multi-center retrospective blind randomized controlled trial between 2021 and 2023. A comprehensive sample of 185 participants was enrolled in the study and categorized into 2 cohorts, each of which was further subdivided into two subgroups. Patients were enrolled in the study after providing informed consent. In the first group (n=95), PVI was performed with power of 50 watts in Ia subgroup (n=55) AI was 400-450 arbitrary units (au) for the posterior wall and 500-550 au for the anterior wall, in Ib (n=40) AI was 400-450 au for the posterior wall and 450-500 au for the anterior wall. In the second group (n=90), PVI was performed at a power of 45 watts, in IIa (n=50) with target AI of 400-450 au for the posterior wall and 500-550 au for the anterior wall in IIb (n=40) AI of 400-450 au for the posterior wall and 450-500 au for the anterior wall. Assessment of conduction block was performed 20 minutes after RFA using a twenty-pole diagnostic electrode (Lasso, Biosense Webster, USA). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT06415149
Study type Interventional
Source People's Friendship University of Russia
Contact
Status Completed
Phase N/A
Start date February 1, 2022
Completion date March 1, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A