Clinical Trials Logo

Clinical Trial Details — Status: Recruiting

Administrative data

NCT number NCT05805189
Other study ID # MERCY
Secondary ID
Status Recruiting
Phase N/A
First received
Last updated
Start date February 9, 2023
Est. completion date June 2025

Study information

Verified date March 2024
Source Maria Cecilia Hospital
Contact Saverio Iacopino, MD
Phone 0545/217228
Email siacopino@gvmnet.it
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Current, worldwide assessments of the prevalence of AF estimate that 33 million people are affected by this cardiac arrhythmia. As the most common sustained atrial arrhythmia, AF has a well-established association with systemic embolic events, stroke, heart failure, and increased mortality. Current treatment guidelines and consensus statements for patients with AF suggest that most patients should be first managed with a pharmaceutical drug therapy; however, when a patient becomes drug refractory (intolerant or non-responsive), catheter ablation by PV isolation (PVI) is recommended. The aim of PVI is abolishment of all conducted electrical activity beyond the isolating lesions. The recent NICE guidelines have established that today RF point-by-point ablation is the most cost-effective treatment approach over a lifetime after failure of 1 or more anti-arrhythmic drugs5, but until now a new technology, HELIOSTAR, RF Balloon, has not been included in this cost-effectiveness analysis


Description:

The multi-electrode RF Balloon catheter (HELIOSTAR, Biosense Webster) is a compliant Balloon with 10 circularly orientated electrodes bonded to its surface. It has been designed to be used in conjunction with the Carto3 system (Biosense Webster, CA). It is able to deliver RF energy directly forming a continuous circular ablation lesion around the PV ostia. With HELIOSTAR, each individual electrode can sense temperature and can be controlled separately. The electrodes can be used for visualization, stimulation, recording and ablation. The compliance of the Balloon allows conformation to the anatomy of the PVs and therefore maximizing tissue contact. The advantages of the RF Balloon include the ease of use to the operator that is associated with Balloon delivery systems, possibility of single shot PVI with tailored RF energy delivery, potentially shorter procedure times and avoidance of collateral damage to non-PVI structures, due to the capacity to individually select and deselect electrodes during ablation.6,7 To date, retrospective analyzes conducted in the RADIANCE and SHINE studies have shown the pre-ablation indicators of optimal electrode positioning and post-RF indicators associated with better outcomes; specifically, baseline impedance range 90-110 Ohms, impedance variability across ten electrodes ≤20 Ohms, baseline electrode temperature ≤31°C, baseline temperature variability ≤3°C and the post-RF indicators (impedance drop ≥12 Ohm and temperature rise ≥6°C) seem to independently predict a durable PVI. To the best of our knowledge, no studies have investigated prospectively the performance of impedance drop and temperature rise of HELIOSTAR ablation in terms of feasibility, acute PVI and post-procedural outcomes.


Recruitment information / eligibility

Status Recruiting
Enrollment 60
Est. completion date June 2025
Est. primary completion date June 2025
Accepts healthy volunteers No
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: The following criteria must be met for subjects to be eligible for inclusion into the study - Subjects indicated for the treatment of paroxysmal AF with the RF ablation system according to current and future Guidelines and system indications for use - Subjects who are willing and capable of providing informed consent - Patients who have stopped amiodarone for at least one month - Subjects whose age is > 18 years old - Subjects whose age is < 80 years old - Subjects who are willing and capable of participating in all testing associated with this clinical study at an approved clinical investigational center Exclusion Criteria: Subjects who meet any one of the following criteria will be excluded from this clinical study - Patients who had already undergo an AF ablation procedure - Any known contraindication to an AF ablation or anticoagulation, including those listed in the instructions for use - Subjects with indication for treatment of AF that is not according to current and future Guidelines and system indications for use - Presence of an intracavitary thrombus - Subjects that are unable or not willing to complete follow-up visits and examination for the duration of the study - Patients with left ventricular ejection fraction < 35% - Women of childbearing potential who are, or plan to become, pregnant during the time of the study (method of assessment upon investigator's discretion) - Hematological contraindications to ionizing radiation exposure - Presence of complex congenital heart disease, and cardiac surgery within 1 month from enrollment - Uncontrolled heart failure - Subjects with severe valvular disease OR with a prosthetic - mechanical or biological- heart valve (not including valve repair and annular rings) - Contraindications to general anesthesia - Subjects who are currently enrolled in another investigational study or registry that would directly interfere with the current study

Study Design


Related Conditions & MeSH terms


Intervention

Procedure:
pulmonary vein (PV) isolation
The settings used during ablation will be for both groups: 15W, unipolar; 5ml/min baseline irrigation, 35ml/min irrigation during inflation/RF application; 55°C target electrode temperature; RF application time 60s for anterior electrodes, 20s for posterior electrodes. The catheter insertion in Pulmonary vein and ablation workflow will be different for two groups.

Locations

Country Name City State
Italy Maria Cecilia Hospital Cotignola Ravenna

Sponsors (1)

Lead Sponsor Collaborator
Maria Cecilia Hospital

Country where clinical trial is conducted

Italy, 

Outcome

Type Measure Description Time frame Safety issue
Primary Pulmonary vein single shot isolation The primary objective of this study is PV single shot isolation in acute and at 1-3-6-12 months follow up with stringent monitoring including medical examination (Echo, ECG, and 24h-Holter)..
It will be assessed the time necessary to reach the isolation, the number of erogations, the fluoroscopy dose and any use of contrast medium and they will be compared between the two arms.
Our aim is to demonstrate that, even in the case of equivalent relapse rates during the follow up, the CARTO guided approach allows patients to benefit from a faster and less invasive procedure compared to the fluoroscopy guided method. This occurs because the former doesn't require contrast medium and the fluoroscopy time is notably reduced.
12 months
Secondary Correlation of biophysical parameters, procedural, and ablation times correlation of biophysical parameters, procedural, and ablation times between two groups. Therefore the following parameters will be collected: Balloonballoon dwelling time, impedance drop, and temperature rise of each RF sessions, rate of bonus and segmental applications, rate of reconnection. One of the endpoint is the recurrence of atrial tachycardia (AT) and AF after the blanking period (3 months), as measured by ECG and 24h-holter. It will be evaluated by the failure-free rate at 12 months post-index procedure in each cohort. 12 months
See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A