Clinical Trials Logo

Clinical Trial Summary

Atrial fibrillation is the most common heart rhythm disorder (arrhythmia) worldwide. Nearly 40 million people are affected by atrial fibrillation worldwide, and this number is expected to increase by over 50% by 2050. Atrial fibrillation can cause strokes, heart attacks, heart failure, poor quality of life and even death. Almost half a million deaths worldwide are expected to be related to atrial fibrillation by 2050, and many billions of dollars are spent on atrial fibrillation related healthcare in North America every year. We believe health outcomes for patients with atrial fibrillation, and healthcare costs associated with treating atrial fibrillation could be improved by optimizing existing treatments for atrial fibrillation and maximizing the likelihood of restoring normal heart rhythm. This allows them to benefit from lower stroke risk, better heart function, fewer symptoms and increased quality of life. Restoring normal sinus rhythm earlier prevents atrial fibrillation from causing permanent structural damage to the heart that in turn, makes atrial fibrillation intractable. Furthermore, patients in whom initial attempts to control atrial fibrillation are unsuccessful frequently require more medications or invasive catheter ablation procedures which are costly and carry substantial risk. Electrical cardioversion is the main way physicians restore normal heart rhythm. In this procedure, the heart is "shocked" back into normal rhythm using two electrodes on the chest. Done correctly, this procedure is safe and effective. Many things are known about electrical cardioversion, for example, the best type and amount of electricity to use. What we don't know is the best position of the electrodes on the chest and whether applying direct, physical pressure to the electrodes makes cardioversion more successful. Our prior research suggests that improving positioning and applying pressure may improve cardioversion, but this finding needs to be verified with a rigorous, dedicated trial. This study will demonstrate whether front-to-back, or front-to-side placement of the electrodes is more effective for electrical cardioversion of atrial fibrillation. We will also demonstrate whether manually applying pressure to the electrodes makes cardioversion more effective. Should our trial demonstrate a benefit for these techniques, we expect them to be universally applied around the world. Because hundreds of thousands of cardioversions are done each year, even small increases in cardioversion success means thousands fewer patients progress to needing more medications or invasive procedures to manage their atrial fibrillation. We will study consenting adults presenting for non-urgent cardioversion of their atrial fibrillation. After explaining the study to participants and gaining their consent, we will randomly assign them to front-to-side or front-to-back electrode placement. Patients who remain in atrial fibrillation after the first shock will randomly receive either manual pressure or not. We will compare the success of cardioversion for front-side versus front-back electrode placement, and for manual pressure versus none. We will evaluate success by using electrocardiograms to assess for restoration of the heart rhythm back to normal. We hypothesize that anterolateral electrode positioning is superior to anteroposterior electrode positioning. We also hypothesize that manual pressure is effective relative to none, when applied in patients who have had one unsuccessful shock already.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT05511389
Study type Interventional
Source McMaster University
Contact William McIntyre, MD
Email william.mcintyre@phri.ca
Status Recruiting
Phase N/A
Start date February 22, 2023
Completion date July 2026

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A