Atrial Fibrillation Clinical Trial
— CASDAF-HDOfficial title:
Characterising the Stable and Dynamic Left Atrial Substrate in Atrial Fibrillation Using High Density Contact and Non-contact Mapping
| NCT number | NCT04229472 |
| Other study ID # | 14295 |
| Secondary ID | |
| Status | Completed |
| Phase | N/A |
| First received | |
| Last updated | |
| Start date | December 7, 2020 |
| Est. completion date | November 2, 2023 |
| Verified date | April 2024 |
| Source | Oxford University Hospitals NHS Trust |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Interventional |
Atrial fibrillation (AF) is the most common sustained arrhythmia, with increasing prevalence associated with an ageing population. Management is challenging, and invasive catheter ablation procedures are increasingly used in those with symptoms refractory to drug therapy. Unfortunately, success rates from this procedure can be limited. This is partly due to limitations in understanding of the mechanisms involved in arrhythmia propagation. There is much interest in the role of structural changes within the muscle of the left atrium resulting in scaring (known as fibrosis). This has been identified on MRI studies and invasive electroanatomical mapping using voltage amplitude of recorded signals as a surrogate measure of tissue properties. This however is affected by the technology used, as it does not routinely incorporate the effect of heart rate on conduction properties. Furthermore, although this aims to identify regions of structural changes, it does not identify more dynamic patterns of conduction seen during AF. This study aims to use a high density mapping catheter (Abbott Advisa HD grid (SE)), which employs a novel algorithm to minimise the effect of wavefront direction on the size of electrical signals. Electroanatomical mapping of the left atrium in patients with atrial fibrillation will be conducted whilst pacing at long and short cycle lengths to assess the effect of pacing rate on conduction properties, assessed using signal morphology and conduction velocity. The same procedure will also be carried out in 5 control patients to allow comparison with normal atria. Two subgroups will also analysed. In the first the aim is to compare the use of the HD grid catheter to a bipolar ablation catheter in carrying out electroanatomical mapping. In the second, to correlate electrical signals obtained with propagation patterns identified using the AcQMap non-contact mapping system and atrial properties identified on cardiac MRI.
| Status | Completed |
| Enrollment | 31 |
| Est. completion date | November 2, 2023 |
| Est. primary completion date | November 2, 2023 |
| Accepts healthy volunteers | Accepts Healthy Volunteers |
| Gender | All |
| Age group | 18 Years and older |
| Eligibility | Inclusion Criteria: - Participant is willing and able to give informed consent for participation in the study. - Male or Female, aged 18 years or above. - Diagnosed with paroxysmal or persistent atrial fibrillation and planned for a catheter ablation procedure (AF ablation group only). - Undergoing elective left sided catheter ablation procedure involving a trans-septal approach (Control group only). - In the Investigator's opinion the participant is able and willing to comply with all trial requirements. Exclusion Criteria: - Previous cardiac surgery. - Previous left atrial ablation (catheter or surgical). - Medical history including any of: atrial fibrillation, atrial flutter, hypertension, diabetes mellitus, chronic obstructive pulmonary disease, significant mitral valve disease (stenosis or regurgitation), pulmonary hypertension, obstructive sleep apnoea, ischaemic heart disease, cerebrovascular disease, peripheral vascular disease, structural heart disease (excluding known accessory pathway), congenital cardiac anomaly (excluding accessory pathway), previous left atrial ablation (catheter or surgical), cardiac surgery (control group only). - Contraindications to MR scanning (such as metallic or electronic objects implanted in your body or history of severe claustrophobia) (AcQMap guided ablation group). - Significantly impaired renal function (eGFR<30ml/min). - Female participant who is pregnant, lactating or planning pregnancy during the course of the trial. - Any other significant disease or disorder which, in the opinion of the Investigator, may either put the participants at risk because of participation in the trial, or may influence the result of the trial, or the participant's ability to participate in the trial. - Participants who have participated in another research trial involving an investigational medicinal product in the past 12 weeks. (Involvement in any other research trial is not a contraindication per se). |
| Country | Name | City | State |
|---|---|---|---|
| United Kingdom | John Radcliffe Hospital | Oxford | Oxfordshire |
| Lead Sponsor | Collaborator |
|---|---|
| Oxford University Hospitals NHS Trust |
United Kingdom,
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Other | Evaluate the effect of cycle length on electrogram morphology in normal subjects | A change in electrogram morphology from normal to abnormal (defined as =3 deflections lasting =50ms), between long and short pacing cycle length. | During ablation procedure | |
| Other | Evaluate the effect of cycle length on electrogram amplitude in normal subjects | A change in electrogram voltage amplitude between long and short pacing cycle length. | During ablation procedure | |
| Other | Evaluate the effect of cycle length on electrogram duration in normal subjects | A change in electrogram duration (in ms) between long and short pacing cycle length. | During ablation procedure | |
| Primary | To define the normal range of voltage amplitude | Mean and distribution of left atrial voltage amplitude across the whole chamber and by segments with lower limit of normal defined as the upper 95% value within the segment with the lowest mean amplitude at long pacing cycle length. | During ablation procedure | |
| Secondary | Effect of pacing cycle length on electrogram morphology | A change in electrogram morphology from normal to abnormal (defined as =3 deflections lasting =50ms) between long and short pacing cycle length in regions of low (<0.5mV), intermediate (0.5-lower limit of normal defined from control group) and normal (defined from control group results) voltage amplitude. | During ablation procedure | |
| Secondary | Effect of pacing cycle length on conduction velocity | Difference in single vector conduction velocity at long and short cycle lengths in regions of low, intermediate and normal voltage. | During ablation procedure | |
| Secondary | To compare electroanatomic voltage mapping (EAVM) performed with a bipolar contact force guided ablation catheter to the Abbott HD grid using orthogonal wave analysis in sinus rhythm. | Difference in voltage amplitude by each method in sinus rhythm. | During ablation procedure | |
| Secondary | To evaluate the distribution of late gadolinium enhancement on cardiac MRI relative to electrogram amplitude identified using the HD grid | Difference in electrogram voltage amplitude at long and short cycle length in regions with and without late gadolinium enhancement on cardiac MRI. | During ablation procedure | |
| Secondary | To evaluate the distribution of electrogram morphologies relative to late gadolinium enhancement on cardiac MRI | Difference in proportion of abnormal electrograms >50ms duration and >3 deflections at long and short cycle length in regions with and without late gadolinium enhancement on cardiac MRI. | During ablation procedure | |
| Secondary | To evaluate the effect of cycle length on conduction velocities relative to distribution of late gadolinium enhancement on cardiac MRI | Difference in conduction velocities at long and short cycle length in regions with and without late gadolinium enhancement on cardiac MRI. | During ablation procedure |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
| Terminated |
NCT04115735 -
His Bundle Recording From Subclavian Vein
|
||
| Completed |
NCT04571385 -
A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF)
|
Phase 2 | |
| Completed |
NCT05366803 -
Women's Health Initiative Silent Atrial Fibrillation Recording Study
|
N/A | |
| Completed |
NCT02864758 -
Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
|
||
| Recruiting |
NCT05442203 -
Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease
|
N/A | |
| Completed |
NCT05599308 -
Evaluation of Blood Pressure Monitor With AFib Screening Feature
|
N/A | |
| Completed |
NCT03790917 -
Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
|
||
| Enrolling by invitation |
NCT05890274 -
Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO
|
N/A | |
| Recruiting |
NCT05266144 -
Atrial Fibrillation Patients Treated With Catheter Ablation
|
||
| Recruiting |
NCT05316870 -
Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation
|
N/A | |
| Not yet recruiting |
NCT06023784 -
The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Recruiting |
NCT04092985 -
Smart Watch iECG for the Detection of Cardiac Arrhythmias
|
||
| Completed |
NCT04087122 -
Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures
|
N/A | |
| Completed |
NCT06283654 -
Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
|
||
| Recruiting |
NCT05416086 -
iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study
|
N/A | |
| Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
| Completed |
NCT04546763 -
Study Watch AF Detection At Home
|
||
| Completed |
NCT03761394 -
Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke
|
N/A |