Clinical Trials Logo

Clinical Trial Summary

Atrial fibrillation (AF) is a cardiac condition that results in patients experiencing an irregular heart beat resulting in symptoms including palpitations and breathlessness. It is known that in most cases, AF is caused by abnormal electrical activity from the top of the left side of the heart (left atrium) which overrides the heart natural pacemaker in the right atrium. Treatment options include tablets which suppress this abnormal electrical activity, but in some patients these are not sufficient and a procedure is carried out where the areas of abnormal electrical activity are disconnected or 'ablated' to prevent AF from occurring. This treatment is well established and performed worldwide, often under general anaesthetic (GA). The heart and lungs sit close together in the chest, and when the lungs are inflated and deflated during the procedure, the heart also moves. This movement is then transmitted to the special wires or 'catheters' that are placed inside the heart to deliver the ablation treatment. Instability during the treatment can result in ineffective areas of ablation which may later contribute to reduced success of the procedure. Previous research has shown that by reducing the movement of the heart under anaesthesia using alternative techniques can improve catheter stability and improve procedural results. Once such technique is called high frequency jet ventilation (HFJV) which allows the lungs to filled with air using fast and shallow breaths resulting in normal blood oxygen levels with little movement in the heart. This technique has been shown to be safe and effective for this procedure but a direct comparison with conventional ventilation has not been done. The investigators wish to test this and determine if using HFJV improves outcomes during the procedure (i.e. can investigators do the treatment faster and more effectively) and if this translates to better outcomes long term.


Clinical Trial Description

Catheter ablation for the treatment of the symptoms of fibrillation is now a well-established technique. The technique is complex and commonly undertaken under general anaesthesia. Catheters are introduced into the circulation from the veins at the top of the leg and advanced to the right side of the heart. Using x-ray and ultrasound guidance, the catheters are passed to the left atrium by puncturing the muscle that divides left and right atria (septum). A model of the left atrium is created and this used to guide the movement of an ablation catheter across the tissue and create ablation lesions that lead to electrical isolation of target sites. Under general anaesthesia, the lungs are inflated and deflated via the ventilator circuit. The expansion of the lungs results in movement of the heart with each respiratory cycle. This leads to catheter instability as the tissue is moved towards and away from a catheter positioned in the left atrium. This movement is particularly marked at the back of the left atrium. This instability can lead to real time variation in the delivery of energy which can result in ineffective lesions. These will then translate acutely to incomplete isolation and the need for further ablation (thereby increasing procedure time) and later into reconnection of tissue which can result in repeated procedures being needed to achieve an effective outcome. Each procedure carries risk of minor and major complications therefore measures to improve first time success are critical. Current research supports the use of steerable catheter sheaths (tubes through which the catheters travel to the atria) and 3 dimensional mapping in improving ablation parameters. Data also exists demonstrating significant variation in catheter contact despite these measures. In order to improve catheter stability further, changes to the mode of ventilation has been studied. Small studies have shown that by stopping cardiac movement altogether by transiently stopping ventilation (apnoea) catheter stability is improved and ablation is more effective. However, intermittent apnoea is not an effective method of ventilation in long cases. An alternative is high frequency jet ventilation. This is where the lungs are ventilated with low volume, high speed and high pressure breaths. This technique is well established and has safety data in upper airway surgery and liver radiology procedures where movement of airways and diaphragm needs to be minimized. In view of this, this technique has been studied in AF ablation and has been shown to improve catheter stability and energy delivery with no increase in complications related to the mode of ventilation. However, existing studies have focused mainly in paroxysmal AF patients (where less ablation is needed) and conducted in a non randomized trial design. The investigators wish to research the use of HFJV in patients undergoing ablation for persistent AF in a prospective and randomised trial to answer the primary and secondary questions shown below. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02968147
Study type Interventional
Source Oxford University Hospitals NHS Trust
Contact
Status Completed
Phase N/A
Start date April 7, 2017
Completion date May 31, 2019

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A