Clinical Trials Logo

Clinical Trial Summary

Atrial fibrillation (AF) is the most common arrhythmia affecting the Canadian population. AF is associated with increased risk of stroke,HF, and even mortality. AF can cause debilitating symptoms, adversely affect patient's (pt's) quality of life and functional status. Hence a strategy of sinus rhythm (SR) may be pursued over a strategy of allowing AF to persist. Percutaneous catheter ablation is an effective alternative to antiarrhythmic drugs (AAD) for maintaining SR. The success rate of PV isolation off AAD is about 80-90% in pt's with PAF, but repeat procedures are required in up to 40% of pt's. After one ablation, the success rate may only be 50-70% off drugs.Current standard ablation procedures for PV antral isolation employ mapping systems which reconstructions of the LA and PV anatomy are created. Visualization may be supplemented by integration of CT/ MRI images and/or intracardiac echocardiography. Robotic navigation has been employed to assist in ablation. Based on single point unipolar radiofrequency (RF) ablation catheter where lesions are created point-by-point around the PVs to obtain electrical isolation.This results in lengthy complex, costly procedures,often more than 4 hours, which requires high degree of operator skill.Creation of contiguous, transmural lesions is challenging with standard single-point RF. A novel multipolar catheter ablation system has been evaluated for achieving PV isolation (PVAC catheter, Medtronic Inc.) An over-the-wire circular mapping/ablation catheter can be advanced into the PV antrum, and multiple lesions around the circumference of the catheter can be delivered simultaneously using duty-cycled unipolar and bipolar RF energy. Early reports, the system can achieve complete PV isolation with reduced fluoroscopy and procedural times using lower powers to achieve more reliable lesion sets.Long-term efficacy also seems comparable to standard RF ablation.This novel technology has potential to broaden the application of AF ablation, making procedures less time-consuming, less complex without compromising procedural efficacy. Published data PVAC technology outcomes are limited to studies with small sample sizes of 12-102 pt's. Data has been restricted to a small number of European centers performing moderate numbers of PVAC procedures. There is no prospective, multicenter data. Little is known about the efficiency of PVAC procedures, allowing for an assessment of cost-effectiveness in using this technology.


Clinical Trial Description

This is a multicenter, open label, prospective, cohort study. Patients undergoing ablation with PVAC technology in up to 15 centers across Canada will be enrolled, ablated, and followed for one year post-ablation. Both primary and secondary objectives of the study will be determined from this cohort of patients. Comparisons to the traditional ablation methods will be made by collecting data from a prospective group of control subjects who are undergoing AF ablation with traditional ablation technology at the same centers by the same operators. Control patients will be enrolled in a 1:2 ratio compared to the PVAC cohort. While the final ratio of control to PVAC patients must be 1:2 by study end for each operator, the ratio may vary while the study is conducted to allow some flexibility in patient recruitment. However, the absolute difference between [# of PVAC patients] and 2x[# control patients] should not exceed 5 at any given time for any operator in any study center ;


Study Design


Related Conditions & MeSH terms


NCT number NCT01562912
Study type Interventional
Source Newmarket Electrophysiology Research Group Inc
Contact
Status Completed
Phase N/A
Start date February 2012
Completion date March 2018

See also
  Status Clinical Trial Phase
Recruiting NCT05654272 - Development of CIRC Technologies
Completed NCT04571385 - A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF) Phase 2
Terminated NCT04115735 - His Bundle Recording From Subclavian Vein
Completed NCT05366803 - Women's Health Initiative Silent Atrial Fibrillation Recording Study N/A
Completed NCT02864758 - Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
Recruiting NCT05442203 - Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease N/A
Completed NCT05599308 - Evaluation of Blood Pressure Monitor With AFib Screening Feature N/A
Completed NCT03790917 - Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
Enrolling by invitation NCT05890274 - Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO N/A
Recruiting NCT05316870 - Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation N/A
Recruiting NCT05266144 - Atrial Fibrillation Patients Treated With Catheter Ablation
Not yet recruiting NCT06023784 - The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block N/A
Recruiting NCT05572814 - Transform: Teaching, Technology, and Teams N/A
Recruiting NCT04092985 - Smart Watch iECG for the Detection of Cardiac Arrhythmias
Completed NCT04087122 - Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures N/A
Completed NCT06283654 - Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Completed NCT05067114 - Solutions for Atrial Fibrillation Edvocacy (SAFE)
Completed NCT04546763 - Study Watch AF Detection At Home
Completed NCT03761394 - Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke N/A