Atrial Fibrillation Clinical Trial
— DISCERN-AFOfficial title:
Discerning Symptomatic and Asymptomatic Episodes Pre and Post Radiofrequency Ablation of Atrial Fibrillation
| NCT number | NCT00745706 |
| Other study ID # | UOHI-01 |
| Secondary ID | |
| Status | Completed |
| Phase | N/A |
| First received | |
| Last updated | |
| Start date | September 2008 |
| Est. completion date | December 2014 |
| Verified date | September 2019 |
| Source | Ottawa Heart Institute Research Corporation |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Interventional |
Atrial Fibrillation (AF) is a common heart rhythm problem that can be eliminated by a radiofrequency ablation procedure. The purpose of this study is to assess the amount of AF that occurs before and after an ablation procedure associated with symptoms versus AF that is not associated with any symptoms. This study will confirm whether patients' symptoms or lack of symptoms post-ablation correlate well with actual episodes of Atrial Fibrillation. This is important information for physicians to know as it will help guide patient care post-ablation in the future. Information on patients' AF episodes will be collected by an implantable loop recorder (ILR) which will be implanted in all study patients 3 months prior to their AF ablation procedure. The ILR will automatically collect information on detected AF episodes while patients will records any symptoms related to AF episodes in study diaries.
| Status | Completed |
| Enrollment | 50 |
| Est. completion date | December 2014 |
| Est. primary completion date | April 2014 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 18 Years and older |
| Eligibility |
Inclusion Criteria: - Age > 18 years old. - First-time ablation procedure for AF. - Symptomatic AF which has been refractory to at least one antiarrhythmic medication. "Symptomatic" patients should be patients who feel that they are aware of when they are in or out of AF. Symptoms may include palpitations, shortness of breath, chest pain, fatigue, or other symptoms, or any combination of the symptoms listed above. - Patients must have paroxysmal or persistent AF. Paroxysmal patients should have had at least 4 episodes of AF in the 6 months prior to assessment/ablation. Paroxysmal AF is defined as AF which spontaneously terminates within 7 days. Persistent AF is defined as AF which sustains for longer than 7 days, or AF lasting less than 7 days which requires either pharmacologic or electrical cardioversion. - At least one episode of AF must have been documented by ECG or Holter within 12 months of inclusion in the study. - No contraindication to systemic anticoagulation with heparin or coumadin. - Patients must be able and willing to provide written informed consent to participate in the study. Exclusion Criteria: - Patients with permanent atrial fibrillation. Permanent AF is defined as chronic, persisting AF (typically more than 1 year) for which cardioversion (pharmacologic or electrical) has failed or will never be attempted. - Patients with AF felt to be secondary to an obvious reversible cause. - Patients with contraindications to systemic anticoagulation with heparin or coumadin. - Patients who have previously undergone atrial fibrillation ablation. - Patients who are or may potentially be pregnant. - Left atrial size > or equal to 55 mm. |
| Country | Name | City | State |
|---|---|---|---|
| Canada | QEII Health Sciences Centre | Halifax | Nova Scotia |
| Canada | Hamilton Health Sciences Centre | Hamilton | Ontario |
| Canada | London Health Sciences Centre | London | Ontario |
| Canada | Hôpital Général de Montréal-McGill | Montréal | Quebec |
| Canada | Southlake Regional Health Centre | Newmarket | Ontario |
| Canada | University of Ottawa Heart Institute | Ottawa | Ontario |
| Canada | Hôpital Laval | Québec | Quebec |
| Canada | Victoria Cardiac Arrhythmia Trials Inc. | Victoria | British Columbia |
| Lead Sponsor | Collaborator |
|---|---|
| Ottawa Heart Institute Research Corporation | Medtronic |
Canada,
Verma A, Champagne J, Sapp J, Essebag V, Novak P, Skanes A, Morillo CA, Khaykin Y, Birnie D. Discerning the incidence of symptomatic and asymptomatic episodes of atrial fibrillation before and after catheter ablation (DISCERN AF): a prospective, multicent — View Citation
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | Incidence of asymptomatic versus symptomatic AF pre-ablation | 3 months | ||
| Primary | Incidence of asymptomatic versus symptomatic AF recurrence > 3months post-AF ablation in patients with "success" after ablation. | 30 months | ||
| Primary | Incidence of asymptomatic versus symptomatic AF recurrence > 3 months post-AF ablation in patients with "failure" after ablation | 30 months | ||
| Secondary | Incidence of peri-procedural and post-procedural embolic events | 24 hours | ||
| Secondary | Correlation of early recurrences (<3 months post-ablation) to late recurrences (> 3 months post-ablation) | 3-30 months | ||
| Secondary | Incidence of very late AF recurrence (beyond 12 months psot-ablation) in "successful" patients post-ablation (determined both by AF episodes and burden) | 30 months | ||
| Secondary | Comparison of "success" and "failure" rates as determined by ILR versus traditional, clinically-indicated ECG and holter monitoring | 30 months | ||
| Secondary | Cost-effectiveness analysis of using ILR monitoring for post-AF ablation monitoring versus traditional follow-up (ECGs, holter, loop recorders) | 30 months |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
| Completed |
NCT04571385 -
A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF)
|
Phase 2 | |
| Terminated |
NCT04115735 -
His Bundle Recording From Subclavian Vein
|
||
| Completed |
NCT05366803 -
Women's Health Initiative Silent Atrial Fibrillation Recording Study
|
N/A | |
| Completed |
NCT02864758 -
Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
|
||
| Recruiting |
NCT05442203 -
Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease
|
N/A | |
| Completed |
NCT05599308 -
Evaluation of Blood Pressure Monitor With AFib Screening Feature
|
N/A | |
| Completed |
NCT03790917 -
Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
|
||
| Enrolling by invitation |
NCT05890274 -
Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO
|
N/A | |
| Recruiting |
NCT05266144 -
Atrial Fibrillation Patients Treated With Catheter Ablation
|
||
| Recruiting |
NCT05316870 -
Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation
|
N/A | |
| Not yet recruiting |
NCT06023784 -
The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Recruiting |
NCT04092985 -
Smart Watch iECG for the Detection of Cardiac Arrhythmias
|
||
| Completed |
NCT04087122 -
Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures
|
N/A | |
| Completed |
NCT06283654 -
Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
|
||
| Recruiting |
NCT05416086 -
iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study
|
N/A | |
| Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
| Completed |
NCT04546763 -
Study Watch AF Detection At Home
|
||
| Completed |
NCT03761394 -
Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke
|
N/A |