Atrial Fibrillation Clinical Trial
Official title:
Electrical Isolation of Pulmonic Veins for Curative Treatment of Atrial Fibrillation: Efficacy of Isolating All Veins Vs Arrhythmogenic Veins Only Using Standard 4-mm or 8-mm Ablation Catheter Vs Saline Irrigated Cooled Tip Catheter
This is a study of different techniques for treatment of atrial fibrillation using a
procedure called radiofrequency catheter ablation. Atrial fibrillation (called AF) is when
the upper chambers of the heart (the atria) beat much faster than the lower chambers,
causing the heart to beat less effectively. AF can cause stroke, impaired performance,
palpitations, shortness of breath, passing out and other symptoms. Radiofrequency ablation
involves placement of catheter/electrode wires into the heart through plastic tubes inserted
into veins / arteries in both the groins and the right side of the neck under local
anesthesia. Radiofrequency energy is delivered to the areas inside the heart that cause the
rapid firing of the atria, causing small lesions or "burns" that destroy the heart tissue
where the extra electrical impulses come from. Commonly this area is where the four
pulmonary veins (PV) deliver blood from the lungs to the left side of the heart, and the
procedure is also referred to as "pulmonary vein isolation" or PVI.
This study compares two different strategies for performing the pulmonary vein isolation
procedure, and compares the effect using two different types of radiofrequency ablation
catheters.
Usually there are 4-5 PVs in each person that bring blood form the different lobes of the
lung into the LA. Typically the inside lining of the LA extends for 3-7 mm inside the PVs
around the entire circumference as they connect (ostium; os) in the form of finger like
projections. These projections are thought to be the sites that initiate AF. The procedure
involves careful definition of the finger like projections between the LA and PV os using
the circular mapping catheter (Lasso). The connections produce specific pattern of
electrical recordings which are targeted using the ablation catheter that utilizes
radio-frequency energy to create local burns at the point of contact with the inside of the
heart. A successful burn destroys these finger-like projections which can be appreciated by
loss of the characteristic electrical recordings which were seen pre-ablation. Using this
technique, a series of radiofrequency ablation lesions are delivered around the
circumference of PV, the end point being obliteration of all electrical recordings between
the left atrium and the PV of interest (also called "Electrical Isolation" of PV from the
rest of the LA). At this time the ablation procedure for AF involves electrical isolation of
either those PVs that have been shown to be the sites from where AF starts (arrhythmogenic
PV) or empirically isolating all the PVs that the patient has (typically 4-5). There is lack
of data showing benefit of one technique over the other. Additionally, in order to create
radiofrequency lesions or burns inside the heart, two different catheter technologies have
been approved and are currently in use: 1) radiofrequency delivery using a standard 4-mm tip
or 8-mm tip catheter, which creates burns at the point of catheter contact that are
approximately 5 mm deep and 2) delivery of radiofrequency energy via saline irrigated cool
tip catheter which is capable of creating deeper burns (5 - 10 mm). Once again, for
electrical isolation of pulmonic veins in pts with AF, there is no data that proves the
benefit of either catheter technology over the other.
PURPOSE AND DURATION: The objectives of the proposed research project are to study:
- The effectiveness of electrical isolation of only the arrhythmogenic pulmonic veins
(PV; partial isolation) vs. electrical isolation empirically of all 4 PV (total
isolation) on long-term (1 year) control of Atrial Fibrillation (AF)
- The effectiveness of a closed loop saline irrigated cooled tip ablation catheter
compared with standard 4-mm tip or 8-mm tip ablation catheter in achieving successful
electrical isolation of pulmonic vein(s).
Study participants shall have a 1:1 chance of getting either ablation of all 4 PVs vs. only
the PVs that are shown to start AF and also for creation of the radiofrequency ablations you
have 1:1 chance of being enrolled either in the arm that utilizes the standard catheter vs.
that which utilizes the saline irrigated cooled tip catheter. The duration of your
participation in the study will be for a maximum of 12 months. This trial is being conducted
in approximately 300 patients.
Hypothesis:
Total electrical isolation of all 4 PVs compared with electrical isolation of only PV(s)
where abnormal impulses are found should be more efficacious in achieving long-term cure of
patients undergoing ablation for AF. Furthermore, the saline irrigated cooled tip catheter
should be able to accomplish successful EI of PV(s) in either group with lesser number of
lesions when compared with the standard 4-mm tip or 8-mm tip ablation catheter.
;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Open Label, Primary Purpose: Treatment
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Recruiting |
NCT05654272 -
Development of CIRC Technologies
|
||
| Terminated |
NCT04115735 -
His Bundle Recording From Subclavian Vein
|
||
| Completed |
NCT04571385 -
A Study Evaluating the Efficacy and Safety of AP30663 for Cardioversion in Participants With Atrial Fibrillation (AF)
|
Phase 2 | |
| Completed |
NCT05366803 -
Women's Health Initiative Silent Atrial Fibrillation Recording Study
|
N/A | |
| Completed |
NCT02864758 -
Benefit-Risk Of Arterial THrombotic prEvention With Rivaroxaban for Atrial Fibrillation in France
|
||
| Recruiting |
NCT05442203 -
Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease
|
N/A | |
| Completed |
NCT05599308 -
Evaluation of Blood Pressure Monitor With AFib Screening Feature
|
N/A | |
| Completed |
NCT03790917 -
Assessment of Adherence to New Oral anTicoagulants in Atrial Fibrillation patiEnts Within the Outpatient registrY
|
||
| Enrolling by invitation |
NCT05890274 -
Atrial Fibrillation (AF) and Electrocardiogram (EKG) Interpretation Project ECHO
|
N/A | |
| Recruiting |
NCT05266144 -
Atrial Fibrillation Patients Treated With Catheter Ablation
|
||
| Recruiting |
NCT05316870 -
Construction and Effect Evaluation of Anticoagulation Management Model in Atrial Fibrillation
|
N/A | |
| Not yet recruiting |
NCT06023784 -
The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block
|
N/A | |
| Recruiting |
NCT05572814 -
Transform: Teaching, Technology, and Teams
|
N/A | |
| Recruiting |
NCT04092985 -
Smart Watch iECG for the Detection of Cardiac Arrhythmias
|
||
| Completed |
NCT04087122 -
Evaluate the Efficiency Impact of Conducting Active Temperature Management During Cardiac Cryoablation Procedures
|
N/A | |
| Completed |
NCT06283654 -
Relieving the Emergency Department by Using a 1-lead ECG Device for Atrial Fibrillation Patients After Pulmonary Vein Isolation
|
||
| Recruiting |
NCT05416086 -
iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study
|
N/A | |
| Completed |
NCT05067114 -
Solutions for Atrial Fibrillation Edvocacy (SAFE)
|
||
| Completed |
NCT04546763 -
Study Watch AF Detection At Home
|
||
| Completed |
NCT03761394 -
Pulsewatch: Smartwatch Monitoring for Atrial Fibrillation After Stroke
|
N/A |