Arthroplasty Clinical Trial
Official title:
A Randomized, Double-Blind, Active- and Placebo-Controlled, Parallel Group, Multicenter Study to Evaluate the Efficacy and Safety of Multiple Doses of CG5503 Immediate Release Formulation in the Treatment of Acute Pain From Total Hip Replacement Surgery Followed by a Voluntary Open-Label Extension
The purpose of this study is to test in patients who have had hip replacement surgery the effectiveness (level of pain control) and the safety of 3 different dose levels of CG5503 compared with placebo and with 10-mg oxycodone during the 72-hour double-blind period and to assess the safety of the drug for 9 days after patients completed the double blind period.
Patients undergoing hip replacement often experience moderate to severe acute pain post-surgery. Normally such pain is controlled when patients receive repeated doses of opioid analgesics. However, opioid therapy is commonly associated with side effects such as nausea, vomiting, sedation, constipation, addiction, tolerance, and respiratory depression. CG5503, a newly synthesized drug also acts as a centrally acting pain reliever but has a dual mode of action. The aim of this study is to investigate the effectiveness (level of pain control) and safety (side effects) of 3 dose levels of CG5503, in an immediate release, (IR) formulation, compared with no drug (placebo) or one dose level of oxycodone (an opioid commonly used to treat post-surgical pain). This study is a randomized, double-blind (neither investigator nor patient will know which treatment was received), active- and placebo-controlled, parallel-group, multicenter study to evaluate the treatment of acute pain from hip replacement surgery. The study will include a blinded 72 hour in-patient phase immediately following hip replacement surgery, during which patients will be treated with either 50-, 75-, or 100-mg CG5503 base IR, a placebo, or 10-mg oxycodone, and pain relief will be periodically assessed. Following this phase, patients wishing to continue treatment with CG5503 IR may enter an outpatient voluntary nonrandomized, open-label extension phase for 9 days during which they will receive 50- or 100-mg CG5503 IR. Assessments of pain relief include the pain intensity numeric rating scale (PI), pain relief numeric rating scale (PAR) and patient global impression of change scale (PGIC). Safety evaluations include monitoring of adverse events, physical examinations, and clinical laboratory tests. Venous blood samples will be collected for the determination of serum concentrations of CG5503 and oxycodone. The null hypothesis for the study is that efficacy results for all CG5503 IR dosage groups are equal to placebo based on the mean sum of pain intensity difference at 48 hours. The alternative study hypothesis is that at least 1 dose strength of CG5503 will be different from placebo in controlling pain at 48 hours. CG5503 base IR 50, or 75, or 100 mg, or oxycodone 10 mg, or placebo, 1 capsule taken by mouth every 4 to 6 hours during the 72 hour postsurgery phase of the study (one extra dose is allowed, if needed for pain); and CG5503, 50 mg base capsules, 1 to 2 tablets taken by mouth every 4 to 6 hours for up to 9 days during the open label portion of the study. All doses of study treatment will be taken with approximately 120 mL of water with or with food. ;
Allocation: Randomized, Endpoint Classification: Safety/Efficacy Study, Intervention Model: Parallel Assignment, Masking: Double Blind (Subject, Caregiver, Investigator, Outcomes Assessor), Primary Purpose: Treatment
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT06323980 -
INHANCE Stemless Reverse Shoulder IDE
|
N/A | |
Completed |
NCT00762944 -
Total Temporomandibular Joint Replacement System Post Approval Study
|
||
Not yet recruiting |
NCT05015101 -
Evaluation of the Clinical and Radiological Outcome of Uncemented Femoral Stems According to Their Proximal Coating
|
||
Completed |
NCT02554149 -
Radiological Measurement of Femoral Stem Version Using Lateral Decubitus Method: A Prospective Study
|
N/A | |
Terminated |
NCT02713906 -
Materialise X-ray Knee Guides for Total Knee Arthroplasty
|
N/A | |
Recruiting |
NCT02828293 -
Understanding GMK Sphere Implant Tibiofemoral Kinematics by Means of Dynamic Videofluoroscopy
|
||
Completed |
NCT02829866 -
AMIStem-H Radiographic Analysis
|
||
Terminated |
NCT00683267 -
Efficacy and Safety Study of 4975 in Patients Undergoing Total Hip Replacement
|
Phase 2 | |
Completed |
NCT04516239 -
Comparison of Metal on Metal Total Hip Arthroplasty and Metal on Metal Total Hip Resurfacing.
|
Phase 4 | |
Recruiting |
NCT04480320 -
Sonography-guided Pericapsular Never Group Block for Hip Arthroplasty
|
N/A | |
Not yet recruiting |
NCT04906681 -
Implementation of a Rehabilitation Technology in Orthopedic and Neurological Rehabilitation to Increase Therapy Dosage: an Exploratory Study
|
Phase 1/Phase 2 | |
Completed |
NCT04403919 -
Knotless Suture in Revision Total Joint Arthroplasty
|
N/A | |
Completed |
NCT03132831 -
Influence of the Operative Day on the Average Duration of Stay in Primary Hip and Knee Replacements
|
||
Active, not recruiting |
NCT03339557 -
Comparison of Three Knee Replacements
|
N/A | |
Active, not recruiting |
NCT02578446 -
Uncemented Tritanium Compared With Cemented Metal-backed Tibia Components in Total Knee Replacement
|
N/A | |
Not yet recruiting |
NCT00756483 -
Stability Plus - Outcomes From Extended Continuum of Care
|
N/A | |
Terminated |
NCT04089371 -
A Post-Market Clinical Evaluation of the ReUnion Reversible Fracture (RFX) System
|
||
Completed |
NCT05248854 -
Effects of Sensorimotor and Core Stabilization Exercises After Total Knee Arthroplasty
|
N/A | |
Not yet recruiting |
NCT02465684 -
Effect of Tourniquet on UKA
|
N/A | |
Completed |
NCT03450681 -
Effectiveness of Pulsed Radiofrequency of the Saphenous Nerve in the Management of Knee Arthroplasty Pain
|
N/A |