Clinical Trials Logo

Clinical Trial Summary

The optimal method of total knee replacement component fixation to the bone remains a challenge. The use of bone cement is considered the gold standard and is the preferred technique for most surgeons. However, uncemented fixation methods have been developed in an attempt to tackle problems that can be seen when cement is used. The cement-bone interlock can deform and degrade over the years and can lead to aseptic loosening, especially in young and active patients. A loosened prosthesis results in an impaired functioning and painful knee in daily life for which a revision of the prosthesis may be necessary. To prevent aseptic loosening and subsequent revision surgery, new methods of uncemented fixation have been developed. One of these methods is to use a highly porous metal called Tritanium®. It can improve the biologic fixation by resembling the characteristics of trabecular bone. It is expected that this surface aids bone ingrowth and to have similar or even better results concerning early fixation properties and long-term durability compared with cemented fixation. Excellent results using this highly porous Tritanium have been seen in total hip surgery already. This single-blinded, randomized clinical trial will assess clinical and radiological outcomes including Roentgen Stereophotogrammetry (RSA) measurements of a newly approved uncemented Triathlon Tritanium CR total knee prosthesis compared with a standard cemented Triathlon metal-backed CR total knee prosthesis (both by Stryker Orthopaedics). Two arms of each 35 patients will be included. The primary outcome measure will be prosthetic migration after two years of the uncemented Triathlon Tritanium CR Total Knee and the cemented Triathlon CR Total Knee by means of RSA. It is hypothesized that the new uncemented Tritanium prosthesis will perform at least equally good in terms of migration and clinical parameters compared with the standard cemented Triathlon. The secondary outcome measure will be long-term (10-year) survival based on the two-year migration patterns combined with clinical factors and radiographic aspects. In order to identify other clinical parameters besides the fixation of the prosthesis components, clinical scores and radiographic aspects will be correlated with the RSA outcome. The 10-year results will be used to verify the predicted long-term survival results.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT02578446
Study type Interventional
Source Region Skane
Contact
Status Active, not recruiting
Phase N/A
Start date October 2015
Completion date March 2026

See also
  Status Clinical Trial Phase
Completed NCT00762944 - Total Temporomandibular Joint Replacement System Post Approval Study
Not yet recruiting NCT05015101 - Evaluation of the Clinical and Radiological Outcome of Uncemented Femoral Stems According to Their Proximal Coating
Terminated NCT02713906 - Materialise X-ray Knee Guides for Total Knee Arthroplasty N/A
Completed NCT02554149 - Radiological Measurement of Femoral Stem Version Using Lateral Decubitus Method: A Prospective Study N/A
Recruiting NCT02828293 - Understanding GMK Sphere Implant Tibiofemoral Kinematics by Means of Dynamic Videofluoroscopy
Completed NCT02829866 - AMIStem-H Radiographic Analysis
Terminated NCT00683267 - Efficacy and Safety Study of 4975 in Patients Undergoing Total Hip Replacement Phase 2
Completed NCT04516239 - Comparison of Metal on Metal Total Hip Arthroplasty and Metal on Metal Total Hip Resurfacing. Phase 4
Not yet recruiting NCT06323980 - INHANCE Stemless Reverse Shoulder IDE N/A
Recruiting NCT04480320 - Sonography-guided Pericapsular Never Group Block for Hip Arthroplasty N/A
Not yet recruiting NCT04906681 - Implementation of a Rehabilitation Technology in Orthopedic and Neurological Rehabilitation to Increase Therapy Dosage: an Exploratory Study Phase 1/Phase 2
Completed NCT04403919 - Knotless Suture in Revision Total Joint Arthroplasty N/A
Completed NCT03132831 - Influence of the Operative Day on the Average Duration of Stay in Primary Hip and Knee Replacements
Active, not recruiting NCT03339557 - Comparison of Three Knee Replacements N/A
Not yet recruiting NCT00756483 - Stability Plus - Outcomes From Extended Continuum of Care N/A
Terminated NCT00364533 - A Study to Evaluate the Effectiveness and Safety of Tapentadol(CG5503) in the Treatment of Acute Pain After Hip Replacement Surgery Compared With Oxycodone and Placebo Followed by a Voluntary Open-Label Extension For Safety Phase 3
Terminated NCT04089371 - A Post-Market Clinical Evaluation of the ReUnion Reversible Fracture (RFX) System
Completed NCT05248854 - Effects of Sensorimotor and Core Stabilization Exercises After Total Knee Arthroplasty N/A
Not yet recruiting NCT02465684 - Effect of Tourniquet on UKA N/A
Completed NCT03450681 - Effectiveness of Pulsed Radiofrequency of the Saphenous Nerve in the Management of Knee Arthroplasty Pain N/A