Aortic Stenosis Clinical Trial
Official title:
Feasibility of 3D Printed Models of Aortic Stenosis in Guiding TAVI Procedure -the 3DP-FAST Study
• The aim of 3DP-FAST study is to analyze the accuracy of replicating cardiovascular anatomical structures using different techniques and to evaluate the feasibility of 3D printed models of aortic stenosis in guiding TAVI procedure. By conducting a comparative analysis of measurements achieved on CCTA images versus measurements obtained with a specialized projection platform by photogrammetry vs 3D printed models of various aortic valvular and perivalvular structures will be evaluated the accuracy of each step of image dataset processing. Furthermore, the study will evaluate the rate of valvular leak or peri-procedural complications such as embolic events or atrio-ventricular conduction block based on coronary computed tomography angiographic and ECG assessment at 1 year after enrollment.
The project is a prospective, cohort, mono-centric study which will be carried out in CardioMed Medical Center in collaboration with the University of Medicine, Pharmacy, Science and Technology "George Emil Palade" of Târgu Mureș. The project will include 20 subjects who present severe aortic stenosis prior to study enrollment. Diagnosis of severe aortic stenosis (AS) as determined by echocardiography, who are deemed eligible for TAVI by the Center of Advanced Research in Multimodal Cardiac Imaging Cardiomed Heart Valve Team. All patients will undergo coronary CT angiography, cardiac perfusion CT and peripheral CT angiography at the moment of enrollment in the study, for complex assessment of aortic valvular and perivalvular structures as well as for peripheral vascular approach. The study will be conducted over a period of 1 year, in which patients will be examined at baseline, and during follow-up visit. At the one-year follow-up, the study subjects will undergo CT coronary angiography for re-evaluation of the aortic valve, in the prospects of analyzing the rate of valvular leak or peri-procedural complications such as embolic events or atrio-ventricular conduction block. In case of non-presentation for the follow-up visit, patients will be contacted via telephone by one of the investigators, and questioned about the general health status, occurrence of cardiovascular or cerebrovascular symptoms and interventions, for possible non-cardiovascular related hospitalizations, as well as regarding the presence of aortic valvular disease rates/repeated interventions. All patients will sign an informed written consent prior to being enrolled in the study. After the screening process, patients that do not present exclusion criteria will be enrolled in the study. Study objectives: Primary: to analyze the accuracy of replicating cardiovascular anatomical structures using different techniques and to evaluate the feasibility of 3D printed models of aortic stenosis in guiding TAVI procedure Secondary: re-evaluation of the aortic valve, in the prospects of analyzing the rate of valvular leak or peri-procedural complications such as embolic events or atrio-ventricular conduction block. Study Timeline: Baseline (day 0) - Obtain and document consent from participant on study consent form. - Verify inclusion/exclusion criteria. - Obtain demographic information, medical history, medication history, alcohol and tobacco use history. - Record results of physical examinations and 12-lead ECG. - Imaging procedures: transthoracic 2-D echocardiography, 128-multislice CT angiography (CCTA) - 3d printed model by FDM technique based on CCTA - Evaluation of 3D printing workflow accuracy Visit 2 (month 6) - Follow-up after TAVI procedure - Record results of physical examinations, 12-lead ECG and medical history. - Imaging procedures: transthoracic 2-D echocardiography Final study visit (month 12) - Record results of physical examinations, 12-lead ECG and medical history. - Imaging procedures: transthoracic 2-D echocardiography, 128-multisclice CCTA - End-point evaluation. Study procedures: - Clinical examination, medical history - 12-lead ECG - 2D transthoracic echocardiography with measurement of: cardiac diameters, volumes, valvular function and regurgitation, pressure gradients, pericardial fat thickness, pericardial effusion, left ventricular global and regional function and ejection fraction. - 128-multislice CT coronary angiography with the evaluation of: epicardial fat volume, coronary plaque burden, total and local calcium score, aortic valve, perivalvular aortic structures, peripheral iliac vessels, ascending and descending segments of aorta. - Processing of DICOM image dataset by performing segmentation and STL adjustments - Processing STL image dataset by performing CAD analysis and adjustments - Processing G-code image dataset and sending to 3d printing station - 3D printing of aortic model including perivalvular aortic structures using fused filaments method Data collection: In a dedicated database that includes all patient information, demographics, medical history, medication, therapeutic procedures, information derived from imaging techniques (echocardiography, CT angiography, CT imaging post-processing and shear stress evaluation). ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04310046 -
Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial
|
N/A | |
Completed |
NCT03332745 -
Mechanism of Decompensation Evaluation - Aortic Stenosis
|
||
Recruiting |
NCT06008080 -
Post-Market Clinical Follow Up Study With Navitor Valve
|
||
Recruiting |
NCT06055751 -
Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
|
||
Active, not recruiting |
NCT04815785 -
Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis
|
N/A | |
Terminated |
NCT02202434 -
Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement
|
N/A | |
Recruiting |
NCT03029026 -
The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
|
||
Active, not recruiting |
NCT02903420 -
A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan)
|
N/A | |
Completed |
NCT02629328 -
CardioCel Tri-leaflet Repair Study
|
N/A | |
Completed |
NCT02306226 -
Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
|
||
Withdrawn |
NCT01648309 -
Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation
|
N/A | |
Completed |
NCT01676727 -
ADVANCE Direct Aortic Study
|
||
Completed |
NCT01422044 -
Risk Prediction in Aortic Stenosis
|
N/A | |
Withdrawn |
NCT00774657 -
Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography
|
N/A | |
Terminated |
NCT00535899 -
Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS)
|
N/A | |
Terminated |
NCT05070130 -
OpSens PRIME CLASS
|
||
Completed |
NCT03314857 -
China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population
|
N/A | |
Completed |
NCT04157920 -
Impact of Predilatation Between Self-expanding Valves
|
N/A | |
Enrolling by invitation |
NCT06212050 -
Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
|
||
Recruiting |
NCT05893082 -
Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR
|
N/A |