Clinical Trials Logo

Clinical Trial Summary

• The aim of 3DP-FAST study is to analyze the accuracy of replicating cardiovascular anatomical structures using different techniques and to evaluate the feasibility of 3D printed models of aortic stenosis in guiding TAVI procedure. By conducting a comparative analysis of measurements achieved on CCTA images versus measurements obtained with a specialized projection platform by photogrammetry vs 3D printed models of various aortic valvular and perivalvular structures will be evaluated the accuracy of each step of image dataset processing. Furthermore, the study will evaluate the rate of valvular leak or peri-procedural complications such as embolic events or atrio-ventricular conduction block based on coronary computed tomography angiographic and ECG assessment at 1 year after enrollment.


Clinical Trial Description

The project is a prospective, cohort, mono-centric study which will be carried out in CardioMed Medical Center in collaboration with the University of Medicine, Pharmacy, Science and Technology "George Emil Palade" of Târgu Mureș. The project will include 20 subjects who present severe aortic stenosis prior to study enrollment. Diagnosis of severe aortic stenosis (AS) as determined by echocardiography, who are deemed eligible for TAVI by the Center of Advanced Research in Multimodal Cardiac Imaging Cardiomed Heart Valve Team. All patients will undergo coronary CT angiography, cardiac perfusion CT and peripheral CT angiography at the moment of enrollment in the study, for complex assessment of aortic valvular and perivalvular structures as well as for peripheral vascular approach. The study will be conducted over a period of 1 year, in which patients will be examined at baseline, and during follow-up visit. At the one-year follow-up, the study subjects will undergo CT coronary angiography for re-evaluation of the aortic valve, in the prospects of analyzing the rate of valvular leak or peri-procedural complications such as embolic events or atrio-ventricular conduction block. In case of non-presentation for the follow-up visit, patients will be contacted via telephone by one of the investigators, and questioned about the general health status, occurrence of cardiovascular or cerebrovascular symptoms and interventions, for possible non-cardiovascular related hospitalizations, as well as regarding the presence of aortic valvular disease rates/repeated interventions. All patients will sign an informed written consent prior to being enrolled in the study. After the screening process, patients that do not present exclusion criteria will be enrolled in the study. Study objectives: Primary: to analyze the accuracy of replicating cardiovascular anatomical structures using different techniques and to evaluate the feasibility of 3D printed models of aortic stenosis in guiding TAVI procedure Secondary: re-evaluation of the aortic valve, in the prospects of analyzing the rate of valvular leak or peri-procedural complications such as embolic events or atrio-ventricular conduction block. Study Timeline: Baseline (day 0) - Obtain and document consent from participant on study consent form. - Verify inclusion/exclusion criteria. - Obtain demographic information, medical history, medication history, alcohol and tobacco use history. - Record results of physical examinations and 12-lead ECG. - Imaging procedures: transthoracic 2-D echocardiography, 128-multislice CT angiography (CCTA) - 3d printed model by FDM technique based on CCTA - Evaluation of 3D printing workflow accuracy Visit 2 (month 6) - Follow-up after TAVI procedure - Record results of physical examinations, 12-lead ECG and medical history. - Imaging procedures: transthoracic 2-D echocardiography Final study visit (month 12) - Record results of physical examinations, 12-lead ECG and medical history. - Imaging procedures: transthoracic 2-D echocardiography, 128-multisclice CCTA - End-point evaluation. Study procedures: - Clinical examination, medical history - 12-lead ECG - 2D transthoracic echocardiography with measurement of: cardiac diameters, volumes, valvular function and regurgitation, pressure gradients, pericardial fat thickness, pericardial effusion, left ventricular global and regional function and ejection fraction. - 128-multislice CT coronary angiography with the evaluation of: epicardial fat volume, coronary plaque burden, total and local calcium score, aortic valve, perivalvular aortic structures, peripheral iliac vessels, ascending and descending segments of aorta. - Processing of DICOM image dataset by performing segmentation and STL adjustments - Processing STL image dataset by performing CAD analysis and adjustments - Processing G-code image dataset and sending to 3d printing station - 3D printing of aortic model including perivalvular aortic structures using fused filaments method Data collection: In a dedicated database that includes all patient information, demographics, medical history, medication, therapeutic procedures, information derived from imaging techniques (echocardiography, CT angiography, CT imaging post-processing and shear stress evaluation). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05484713
Study type Observational
Source Cardio Med Medical Center
Contact Daniel Cernica, MD
Phone +40 265 217 333
Email daniel.cernica@gmail.com
Status Recruiting
Phase
Start date July 8, 2022
Completion date July 2023

See also
  Status Clinical Trial Phase
Recruiting NCT04310046 - Optimal Timing of Transcatheter Aortic Valve Implantation and Percutaneous Coronary Intervention - The TAVI PCI Trial N/A
Completed NCT03332745 - Mechanism of Decompensation Evaluation - Aortic Stenosis
Recruiting NCT06008080 - Post-Market Clinical Follow Up Study With Navitor Valve
Recruiting NCT06055751 - Long Term Evaluation of Cardiac Arrhythmias After Transcatheter Aortic Valve Implantation -The LOCATE Registry
Active, not recruiting NCT04815785 - Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis N/A
Terminated NCT02202434 - Safety and Efficacy Study of Lotus Valve for Transcatheter Aortic Valve Replacement N/A
Recruiting NCT03029026 - The Role of Occult Cardiac Amyloid in the Elderly With Aortic Stenosis.
Active, not recruiting NCT02903420 - A Clinical Trial of Transcatheter Aortic Valves in Dialysis Patients (Japan) N/A
Completed NCT02629328 - CardioCel Tri-leaflet Repair Study N/A
Completed NCT02306226 - Symetis ACURATE Neo™ Valve Implantation SAVI TF Registry
Withdrawn NCT01648309 - Neuropsychological Testing in Patients Undergoing Transvascular Aortic Valve Implantation N/A
Completed NCT01676727 - ADVANCE Direct Aortic Study
Completed NCT01422044 - Risk Prediction in Aortic Stenosis N/A
Withdrawn NCT00774657 - Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography N/A
Terminated NCT00535899 - Speckle Tracking Imaging in Patients With Low Ejection Fraction Aortic Stenosis (SPArKLE-AS) N/A
Terminated NCT05070130 - OpSens PRIME CLASS
Completed NCT03314857 - China XT: Safety and Effectiveness of Edwards Lifesciences SAPIEN XT THV in the Chinese Population N/A
Completed NCT04157920 - Impact of Predilatation Between Self-expanding Valves N/A
Enrolling by invitation NCT06212050 - Feasibility, Safety, and Effectiveness of the ACURATE neo2 Transcatheter Heart Valve for Severe Bicuspid Aortic Stenosis
Recruiting NCT05893082 - Multicenter Feasibility Trial of the F2 Filter and Delivery System for Embolic Protection During TAVR N/A