NCT ID: NCT05956873 Completed - Clinical trials for Thoracoabdominal Aortic Aneurysm

Endovascular Aortic Repair of Free and Contained Ruptured Thoraco-Abdominal Aortic Aneurysm

REVAR-TAAA
Start date: January 1, 2015
Phase:
Study type: Observational

Ruptured thoracoabdominal aortic aneurysm (TAAA) represents an emergency medical challenge that needs to be treated promptly. Over the past years different endovascular techniques have emerged such as fenestrated or branched endovascular aortic repair (FB-EVAR). However, FB-EVAR is a technique that uses a custom-made device which needs to be manufactured and this process take months, therefore, it could not be used in urgent settings. Off-the-shelf graft stents are pre-made graft stents, which can be used in urgent cases. A retrospective, multicenter cohort study was planned to include patients who underwent endovascular procedures between January 2015 and January 2022 (85 months) to evaluate the technical and survival outcomes of the use of off-the-shelf stent graft, physician-modified endograft and parallel graft technique in endovascular aortic repair of free and contained ruptured TAAA. Data will be collected anonymously and retrospectively, including patient demographics, risk factors, diagnosis and anatomical details, procedure details and post-operative outcomes.

NCT ID: NCT05414318 Completed - Clinical trials for Thoracic Aortic Aneurysm

CTAG Dissection/Trauma Post Marketing Surveillance Japan

Start date: January 5, 2016
Phase:
Study type: Observational

Post Marketing Surveillance of the Conformable GORE® TAG® Thoracic Endoprosthesis

NCT ID: NCT05266781 Completed - Clinical trials for Thoracoabdominal Aortic Aneurysms

A PROpensity Score Matching Analysis on ENDovascular vs Open Thoraco-Abdominal Aortic Aneurysm Repair (PRO-ENDO TAAA Study)

PRO-ENDO TAAA
Start date: April 1, 2022
Phase:
Study type: Observational

The purpose of the registry is to compare the surgical and endovascular approaches to the treatment of thoracoabdominal aortic aneurysms.

NCT ID: NCT05141123 Completed - Aneurysm Abdominal Clinical Trials

Registry of Patients Treated by Preloaded Fenestrated Stent-graft Designs for Complex Endovascular Aortic Procedures

Start date: October 30, 2022
Phase:
Study type: Observational

The aim of the study is to evaluate the outcomes of the preloaded stent-graft design (PLD) in the routine treatment of para-renal and thoraco-abdominal aneurysms. Results and postoperative events are reported in accordance with the current reporting standards for endovascular aortic repair prepared and revised by the Ad Hoc Committee for Standardized Reporting Practices in Vascular Surgery of The Society for Vascular Surgery/American Association for Vascular Surgery. The Registry will include approximately 300 patients treated from January 2015 to May 2021 (retrospective arm) and June 2021 to June 2023 (perspective arm) for the routine treatment of para-renal and thoraco-abdominal aneurysms. To reach 300 patients, the enrollments can be extended until June 2026.

NCT ID: NCT04930172 Completed - Clinical trials for Aortic Aneurysm, Abdominal

TOtal tRansfemoral branCHed endovasCular tHoracoabdominal Aortic Repair Registry

Start date: October 30, 2022
Phase:
Study type: Observational

The purpose of the registry is to evaluate the peri-operative, short-, and mid- outcomes of endovascular treatment of thoracoabdominal aneurysms with multibranched endografts via total transfemoral approach for visceral vessels cannulation using steerable sheaths

NCT ID: NCT04909190 Completed - Stroke Clinical Trials

Saline Flush to Reduce the Amount of Residual Air Inside a Stentgraft Delivery System

SAFRANE
Start date: June 10, 2021
Phase: N/A
Study type: Interventional

Non-randomized studies have shown that de-airing of the delivery system with an increased volume of saline may be associated to a decrease in periprocedural stroke during thoracic endovascular aortic repair. This study is designed to provide evidence that 4xIFU-dose volume of saline flush vs. standard IFU-dose saline flush is associated to a decrease in the amount of intra-sac air detected on the first follow-up imaging after EVAR.

NCT ID: NCT04756778 Completed - Clinical trials for Thoracic Aortic Aneurysm

Indexed Aortic Area in Bicuspid Aortic Valve Aortopathy

Start date: January 27, 2017
Phase:
Study type: Observational

This study aims to determine the relationship between the cross-sectional aortic area/patient height ratio (indexed aortic area) and absolute aortic diameter in proximal thoracic aortic aneurysms associated with a bicuspid valve. This will shed light on whether aneurysms with smaller diameters than those recommended for surgical intervention by guidelines are still at risk of aortic complications attending an abnormally high indexed aortic area.

NCT ID: NCT04663074 Completed - Clinical trials for Thoracic Aortic Aneurysm

Intravascular Ultrasound (IVUS) in Complex Aortic Endovascular Interventions

Start date: May 22, 2020
Phase:
Study type: Observational [Patient Registry]

The study aims to investigate the applicability of intravascular ultrasound (IVUS) in the endovascular therapy of juxta-, supra- and thoracoabdominal aortic aneurysms. The focus of the study is on the intraoperative and postoperative evaluation of the geometric data of bridging stentgrafts in terms of patency, occurrence of stenosis and/or kinking.

NCT ID: NCT04430114 Completed - Aneurysm Abdominal Clinical Trials

MuLtibranchEd Graft for OPen RepAir of ThoRacoabdominal Aneurysms

Start date: June 5, 2020
Phase: N/A
Study type: Interventional

The objective of the study is the evaluation of the technical success and clinical outcomes of the surgical treatment of thoraco-abdominal aortic aneurysms treated by Jotec "TAAA spinal loop graft" "custom made "CE equivalent" branched prosthesis, compared with the patient cohort already treated with standard and / or bench-top prostheses Gelweave ™ Coselli Thoracoabdominal Grafts.

NCT ID: NCT04190979 Completed - Acute Kidney Injury Clinical Trials

Clinical Application of the Medyria TrackCath System in Endovascular Repair of Abdominal Aortic Aneurysms (AAA)

ACCESS
Start date: March 17, 2018
Phase: N/A
Study type: Interventional

Pre-market, single-arm, prospective, open-label, multi-center clinical trial aimed at assessing the safety and the performance of the Medyria TrackCath system in patients undergoing endovascular intervention.