Aortic Aneurysm, Abdominal Clinical Trial
Official title:
Treatment With Endovascular or Open Repair for AAA - Comparison of Perioperative Myocardial Injury Detected With Holter-ECG and Troponin
Comparison of elective infrarenal aneurysm surgery with open and endovascular technique, respectively, for subclinical ischemic myocardial injury detectable with troponin T and/or 3-channel Holter ECG with ST analysis
Background: Traditional open surgery for abdominal aortic aneurysm (AAA) is burdened with complication risk from several organ systems, and also mortality figures of 3.5 - 5.5%. Over 50% of early mortality can be attributed to cardiovascular complications. Myocardial infarction is the dominant organ-specific cause of both early and late mortality in patients operated on for AAA. Endovascular surgery (EndoVascular Aortic Repair, EVAR) was developed during the 90's as an alternative method that is considered less invasive and more well-tolerated from a cardiovascular perspective. Troponin T is a very sensitive and specific marker that predicts mortality in patients with acute symptoms of unstable angina and/or heart attack. Previous studies have also shown a high incidence of elevated troponin levels in patients who underwent major surgical procedures, especially vascular surgery, even in the absence of corresponding clinical or ECG-related symptoms of cardiac muscle injury. Several studies have also demonstrated that elevated troponin levels after surgery predict increased morbidity and mortality both short-term and long-term. Objective: To prospectively compare elective open and endovascular surgery of AAA with respect to myocardial injury detectable with troponin T. Furthermore, to compare open and endovascular AAA surgery for the total number of periods of oxygen deficiency in cardiac muscle during and at early stages after surgery using a special ECG method (48-hour 3-channel Holter ECG with ST analysis). Main aim of the study: To assess whether EVAR induce less myocardial injury compared with open repair for AAA. Significance: Myocardial infarction is the predominant cause of mortality in open surgical procedure for AAA. In several previous studies, troponin T rise has been associated with impaired both short-term and long-term prognosis in elderly patients undergoing major elective surgery. This study may provide information on whether the endovascular technique provides a reduction in myocardial injury, measured as elevated troponin T or myocardial ischemia with 3-channel Holter ECG. In this way, our study can provide improved decision support in the choice of the most appropriate treatment method in the individual case. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03657979 -
TAP-Block in Abdominal Aortic Surgery
|
Phase 4 | |
Enrolling by invitation |
NCT01465425 -
Extracolonic Findings on Computed Tomography (CT) Colonography
|
||
Completed |
NCT02845167 -
Effect of Preoperative Exercise on Postoperative Outcome in AAA Patients: Pilot Study
|
N/A | |
Not yet recruiting |
NCT00358085 -
NExT ERA: National Expertise Based Trial of Elective Repair of Abdominal Aortic Aneurysms: A Pilot Study
|
Phase 3 | |
Terminated |
NCT00118573 -
Comparison of Surveillance Versus Aortic Endografting for Small Aneurysm Repair
|
Phase 4 | |
Completed |
NCT04792411 -
Adherence and Acceptability of a Remote, Home-based, Pre-surgery Programme for Patients Undergoing Abdominal Aortic Aneurysm Surgery
|
N/A | |
Completed |
NCT04930172 -
TOtal tRansfemoral branCHed endovasCular tHoracoabdominal Aortic Repair Registry
|
||
Withdrawn |
NCT02995642 -
Targeted PET/CT and PET/MRI Imaging of Vascular Inflammation
|
Phase 2 | |
Completed |
NCT01980901 -
Post-Approval Study of the Ovation™/Ovation Prime™ Abdominal Stent Graft System
|
||
Active, not recruiting |
NCT01698671 -
InterGard Synergy Post-Marketing Surveillance Study
|
N/A | |
Enrolling by invitation |
NCT00831870 -
EndoSure Sensor for Long-term Follow-up After Endovascular AAA Repair
|
N/A | |
Recruiting |
NCT05972018 -
Liposomal Bupivacaine/Bupivacaine in RS Blocks vs. Ropivacaine in RS Blocks And Catheters
|
Phase 4 | |
Not yet recruiting |
NCT02997618 -
The AAA Get Fit Trial: A Pilot Randomised Controlled Trial of Community Based Exercise in Patients With Abdominal Aortic Aneurysms
|
N/A | |
Active, not recruiting |
NCT02907762 -
Aorfix Intelliflex First in Human Study
|
||
Completed |
NCT00349947 -
Exercise Therapy to Treat Adults With Abdominal Aortic Aneurysms
|
Phase 1 | |
Completed |
NCT04080557 -
Abdominal Aortic Aneurysm Patients Remain at Risk for Delirium on the Surgical Ward After Intensive Care Unit Dismissal
|
||
Recruiting |
NCT05484115 -
Comparison of EVAR and ESAR for Infrarenal Aortic Aneurysms With a Wide Proximal Neck
|
N/A | |
Recruiting |
NCT04503395 -
ShOrt neCK AAA RAndomized Trial - ESAR and FEVAR: SOCRATES
|
N/A | |
Completed |
NCT02867501 -
Venous Distension in Patients With Aneurysmatic Arterial Disease
|
N/A | |
Recruiting |
NCT02345590 -
Eplerenone in the Management of Abdominal Aortic Aneurysms
|
Phase 4 |