Clinical Trials Logo

Clinical Trial Summary

A minimum of 50 patients with ankle end-stage arthritis will be randomized in two parallel groups for surgery. One group will receive a total ankle replacement through an anterior approach and the other group a total ankle replacement via a lateral approach. Patients will be evaluated for a mean follow-up of two years in terms of complications, implant survival and functional results. One of the primary objectives of the study is analyzing the safety of the lateral and anterior approaches for total ankle replacement.


Clinical Trial Description

A minimum of 50 patients with ankle end-stage arthritis will be randomized in two parallel groups for surgery. One group will receive a total ankle replacement through an anterior approach and the other group a total ankle replacement via a lateral approach. Patients will be evaluated for a mean follow-up of two years in terms of complications, implant survival and functional results. One of the primary objectives of the study is analyzing the safety of the lateral and anterior approaches for total ankle replacement. The anterior approach uses an interval between the anterior tibial tendon and the extensor digitorum longus tendon to reach the joint. The anterior tibial artery and the deep peroneal nerve must be identified and protected. Once the ankle is reached, the joint is roughly prepared and the cutting guides for the implants are inserted. The position is checked, and the size of the prosthesis is determined. There are several commercial prostheses designed for this approach, although we decided to use the Infinity™ Total Ankle System (Stryker Medical®) to minimize bias. After alignment examination, the implants are inserted, the planes are closed, and the wound is covered. The patient is placed in a cast for three weeks and starts weight-bearing in a boot after this period, using it for three more weeks. The lateral approach utilizes an incision over the posterior aspect of the fibula. The lateral malleolus is osteotomized 1.5cm proximal to the joint and reflected distally to provide access to the articulation. An external frame is placed around the limb that supplies guidance for the prosthesis cuts. The sizing and position are determined and a Trabecular Metal Total Ankle™ (ZimmerBiomet®) is placed, the only available implant for the lateral approach. The fibula is reduced and fixed using a low profile anatomical lateral plate and screws. Planes are closed, the wound protected, and a cast placed. The post-operative carry is the same as the anterior approach. Weight bearing CT (WBCT) scans will be used to evaluate outcomes. WBCT is the standard of care for the preoperative and postoperative assessment of patients undergoing total ankle replacement in our institution. Many secondary outcomes will be also evaluated through WBCT since they can better depict alignment, predict failure and diagnose complications (subsidence, cysts). No extra WBCT will be performed other than what we normally do for patients. Randomization will be performed previously at the beginning of the study and will be performed by an outside researcher. Allocation will happen during surgery scheduling. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05562154
Study type Interventional
Source University of Iowa
Contact
Status Withdrawn
Phase N/A
Start date July 5, 2022
Completion date December 14, 2023

See also
  Status Clinical Trial Phase
Completed NCT02508233 - Cross-cultural Adaptation and Validation of the Ankle Osteoarthritis Scale (AOS) for Use in French-speaking Populations N/A
Completed NCT01504438 - Prospective Randomized Evaluation of a Two and Three Piece Total Ankle Replacement N/A
Active, not recruiting NCT03440008 - Improving the Detection, Classification and Treatment of Misaligned Arthritic Ankles
Active, not recruiting NCT06404801 - Development of Stance Control Orthotic Knee Joint For Improvement of KAFO Users
Active, not recruiting NCT04405297 - A Disease-based Treatment Study for Diagnosed Osteoarthritis Utilizing Adipose-derived Regenerative Cells
Completed NCT01760577 - Effects of Intraarticular Botulinum Toxin A in Ankle Osteoarthritis N/A
Active, not recruiting NCT04998162 - Injections of SVF in Ankle Osteoarthritis N/A
Completed NCT03356951 - Gait Analysis Following Total Ankle Replacement and Subtalar Fusion N/A
Completed NCT02489188 - Gait Asymmetry Assessed Using Portable Gait Analysis System
Completed NCT01986244 - Total Ankle Replacement for Ankle Arthritis
Completed NCT03567187 - Cryoneurolysis for Improvements in Pain, ADL and QOL in Patients With Ankle Osteoarthritis N/A
Completed NCT05868759 - Assessment of Preoperative and Postoperative Ankle Kinematics N/A
Recruiting NCT06193057 - Comparison of Customized and Standard Total Ankle Prostheses N/A
Recruiting NCT06028763 - Development of Biomedical Technology for the Treatment of Ankle Cartilage Using Injectable Biocomposite Hydrogel N/A
Completed NCT04022928 - A Single Intraarticular Injection of Platelet-Rich Plasma on Pain and Physical Function in Patients With Ankle OA N/A
Not yet recruiting NCT03573245 - Tranexamic Acid in Major Orthopedic Surgery: Comparison of 3 Dosage Regimen
Completed NCT02629731 - Orthotic Dose Response Study N/A
Recruiting NCT03157141 - Ankle Osteoarthritis N/A
Active, not recruiting NCT03524729 - Do Rocker Bottom Shoes and Ankle-Foot Orthoses Reduce Pain and Improve Mobility for Ankle Osteoarthritis Patients N/A
Completed NCT03711747 - Indications for Osteochondral Allograft Transplantation