View clinical trials related to Ankle Fractures.
Filter by:This application addresses the Peer Reviewed Medical Research Program Investigator-Initiated Research Award FY21 W81XWH-22-CPMRP-IIRA area of Chronic Pain Management Research Program- The investigators will utilize subjects who have sustained ankle fractures and may develop chronic pain following bone union. No attempt will be made to affect the experimental outcome in the subjects. This study will adhere to a core set of standards for rigorous study design and reporting to maximize the reproducibility and translational potential of research.
Ankle fracture is one of the most common orthopedic injuries. Approximately, 20% of surgically treated ankle fractures are associated with syndesmotic instability.According to the mechanism of the injury the syndesmotic disruption should be considered in Danis-Weber C-type fractures. However, such injuries were also frequently seen in Danis-Weber B-type fractures. Failure to detect and repair syndesmotic injuries early may result in poor clinical outcomes and complications affecting ankle function, such as long-term residual pain, post traumatic arthritis, and ankle impingement syndromes. Therefore, aggressive treatment is important when facing syndesmotic instability . The distal tibiofibular syndesmosis is important for stability of the ankle mortise and thus for weight transmission and walking. Syndesmotic injuries are most commonly associated with fibular fractures, but they can also occur in isolation or with damage to the lateral ankle ligament after traumatic supination. The need for syndesmotic fixation of the distal tibiofibular joint has been controversia. fracture does not correlate reliably with the extent of the interosseous membrane tears identified on MRI of ankle fractures, and thus estimation of the integrity of the interosseous membrane and subsequent need for trans-syndesmotic fixation cannot be based solely on the level of the fibular fracture. An intraoperative syndesmotic stress test can establish the presence or absence of syndesmotic instability, evaluating the integrity of the syndesmosis by grasping the stabilised fibula with a hook or clamp and pulling it laterally. If more than 3 or 4 mm of lateral displacement occurs, syndesmotic fixation is necessary. Most authors recommend surgical placement of a trans-fixation screw after anatomical reduction of the syndesmosis if a disruption is diagnosed to avoid complications.The main aims of treatment for dislocation of the distal tibiofibular syndesmosis are to restore the original anatomy and normal function and to recreate the stability of the ankle joint. The syndesmosis is traditionally fixed with a metallic screw, which is a method that has been used for decades and demonstrates good to excellent outcomes. Some surgeons prefer Fixation of syndesmosis with screw in maximum ankle dorsiflexion and others prefer fixation in neutral position of ankle.in this study we are going to compare between these two
The purpose of the study is to evaluate the ability of the Fibulink Syndesmosis Repair System to maintain reduction of the ankle syndesmosis. Appropriate reduction of the syndesmosis is critical due the changes in tibiotalar contact pressure observed in cadaveric studies.6,7 Malreduction and instability of the distal tibiotalar joint can lead to chronic instability, increased articular damage and ultimately degenerative arthritis.7,8 Medial to lateral translation of distal tibia and fibula of 2 mm or more has been considered pathologic.9 Earlier biomechanical study demonstrated the Fibulink system is superior in maintaining displacement of less than 2 mm.4 Given the improved strength, we also look to evaluate the outcomes of initiating full weight bearing (100%) with Controlled Ankle Motion (CAM) boot at 4 weeks postoperatively. One of the big limitations for trans-osseous screw fixation is delayed weight bearing due to risk of screw breakage.1 Suture button technique allowed for early weight bearing with average of 6 weeks postoperatively using TightRope.2,10-12By initiating full weight bearing (100%) with CAM boot at 4 weeks postoperatively, this would be a significant improvement in current clinical practice.
The application of the WALANT technique for foot and ankle surgery (joint fusion, implant removal and tendon repair, etc.) is limited. In our study, using the WALANT technique for ARIF in ankle fractures. The effect of this application on clinical outcomes will be prospectively evaluated.
This clinical trial aims to compare a Mixed Reality Viewer in the preoperative informed consent process to standard fracture visualization. The participants population are patients with an indication for surgery of a distal radius fracture, upper ankle fracture or proximal humerus fracture using plate osteosynthesis. The main questions aim to answer are: - Does the use of the Mixed Reality Viewer improve patient understanding? - Does the use of the Mixed Reality Viewer improve patient satisfaction? - Does the use of the Mixed Reality Viewer reduce patient preoperative anxiety? Participants will have their fracture presented via the Mixed Reality Viewer. Researchers will compare standard fracture imaging using X-ray or CT scans to see if there is any difference in understanding, satisfaction and anxiety.
The purpose is to find out if incorporation of an intraoperative electro auricular acupuncture protocol when added to a standard multimodal analgesic regimen for patients undergoing surgery to repair lower leg fracture under spinal anesthesia will help reduce postoperative opioid use.
Ankle injuries are among the most common traumatological injuries of the lower limb accounting for approximately 50% of all sports injuries and 25% of musculoskeletal injuries in general. Correct initial diagnosis and proper management is important to reduce the risk of recurrent ankle instability and other complications, such as reduced range of motion, increased ligament laxity, instability, tendon enthesopathy, possible swelling, formation of calcifications, reduced load on the affected limbs while standing and walking, increased pain intensity and pain duration. To date, few studies showed that the effectiveness of physical therapy increases when it is modified based on diagnostic ultrasonography findings. Sonography is not burdensome for the patient, has high reproducibility, and enables dynamic examination and comparison of the interrelationships of individual structures. The aim of this study is to investigate if targeted physiotherapy for post-traumatic ankle conditions designed based of diagnostic ultrasonography findings is more effective than standard physiotherapy. The study hypothesis is that in the experimental group there will be a smaller number of complications of post-traumatic ankle conditions than in the control group. If confirmed the study could have clinical implications.
The aim of this study is to evaluate the outcomes after non-operative treatment of weightbearing stable bi-and trimalleolar ankle fractures.
This project consists of a randomized controlled study design. Study candidates will include all patients 18 years or older, who were evaluated at UCSD and found to have an acute ankle syndesmosis injury requiring surgery. Patients who consent to study participation will be randomized to receive one of two standard of care procedures - either a suture button or Fibulink implant. Outcome measures, including the Olerud-Molander and American Orthopaedic Foot and Ankle Society scores, pain, range of motion, time to return to work, and radiographic evaluation will be collected for each participant. Given the potential degenerative changes and poor radiographic and clinical outcomes with inadequate repair of the syndesmosis, it is imperative to evaluate existing and emerging methods of fixation for patients with acute ankle fractures with syndesmosis injuries.
The investigators aim to evaluate the fixation of the ankle syndesmosis in appropriate ankle fractures with bioabsorbable screws. Ankle fractures are common, and a proportion of them involve both fracture of the bone and also disruption of the syndesmosis, a strong ligamentous complex connecting the distal fibula and tibia. If left without fixation this causes a high incidence of pain and early arthritis. The most common technique for fixation of this syndesmosis involves the use of the same type of metal screws used to fix the fractured bones. As the syndesmosis permits small degrees of movement in normal subjects, fixation of this with metal usually leads to screw breakage and, or pain. It is common practice to remove these screws after a period of time once the syndesmosis has healed in the correct position. Bioabsorbable screws have the advantage of allowing small increments of movement, and also resorb naturally therefore do not have to be removed with a second surgical procedure. They are used in other centres worldwide, and the investigators therefore seek to evaluate syndesmosis fixation with them in their unit. The investigators would aim to recruit patients who have a syndesmotic injury requiring fixation, and who can consent to participating. They would undergo an identical surgical procedure to the standard current practice, apart from using a bioabsorbable screw in exchange for the metallic screw for syndesmosis fixation. All other components would remain unchanged, as would post operative protocol and management. To evaluate the fixation the investigators would use a limited CT scan (equivalent of about 3 months background radiation) after the time of fixation and at one year. This will help to assess the maintenance of reduction of the syndesmosis with time. The investigators would also assess patient reported outcome measures and pain scores, length of procedure and intraoperative radiation levels, weight bearing distribution tests, as well as any complication that may arise.