Study information

Verified date October 2011
Source Medical University of Vienna
Contact n/a
Is FDA regulated No
Health authority Austria: Ethikkommission
Study type Interventional

Clinical Trial Summary

MiroCam® is the new video capsule endoscope of IntroMedic®. By using a novel transmission technology it promises a longer battery life expectancy with consequential impact on the length of the video recorded for diagnostic evaluation. As the investigators know about the shortcoming of battery life expectancy from many capsule examinations that were inconclusive because the ileocaecal transit was not filmed, the investigators would appreciate to have a capsule with extended video recording to improve the diagnostic yield of capsule examinations. Therefore the investigators want to compare MiroCam® to our routinely used Olympus® Enteropro EndoCapsule® in the context of a half-year clinical trial. Focussing on the total video length as well as on the rate of video-recorded ileocaecal transitions as surrogate parameters the investigators want to find out whether one of the two products provides superior diagnostic information in order to reduce the amount of inconclusive examinations.


Description:

Introduction

Video capsule endoscopy (VCE) is an important tool in the diagnostic management of several gastrointestinal (GI) disorders. Taking a video while passing the GI tract, VCE is the only technique providing image information of the whole small bowel. It is a comfortable and safe procedure; complications due to capsule retention are rare [1]. The main disadvantage of VCE is made up by its only dependence on macroscopic information. Therefore it can not be reliably used for the detection of disorders that need histological confirmation. However, lots of macroscopic pathologies can be diagnosed or excluded by VCE. Above all, obscure digestive bleeding (ODB) has become the main indication for the use of VCE [2].

Independent from the type of bowel preparation used, the ileocaecal transit cannot be visualized in up to 20 percent of VCE examinations, which means the loss of diagnostic information of the last intestinal parts [3]. Risk factors of such incomplete VCE include previous small-bowel surgery, hospitalization, moderate or poor bowel cleansing and a gastric transit time longer than 45 minutes [4]. Especially in the latter case, the success of the examination is determined by the battery life expectancy of the capsule technology used [5].

The new MiroCam®, a brand of IntroMedic®, is advertised to have a longer battery life expectancy than competitive products throughout the market. To prove this pronouncement, a pilot-study of 16 patients was presented by He Man Kim at the UEGW 2008, comparing MiroCam® to Given®'s PillCam® by sequential application of both capsules. Although the battery life expectancy of MiroCam® was significantly higher, there was no significant difference in the diagnostic yield of both products [6]. Currently a similar comparison study between MiroCam® and Pill Cam® is ongoing in France, involving a higher amount of patients [unpublished data].

Study Aims

In this prospective study we want to compare IntroMedic®'s MiroCam® to Olympus® Enteropro EndoCapsule® which was so far routinely used at our department. We want to investigate whether one of the two products provides superior diagnostic information about the small bowel. The primary endpoint will be the total video length registered as well as the rate of successful ileocoecal transitions during ongoing video registration. The secondary end point will be the number of pathologies detected by each capsule. If there will be a significant difference between the two tested products, preferred usage of the superior product may improve the diagnostic yield of future examinations by avoiding incomplete video registration of the small bowel.

Study Design

Prospective Study without randomisation or blinding

Study Population

Patients transferred to our unit to undergo video capsule endoscopy because of

- Obscure digestive bleeding (ODB)

- Chronic anaemia of unknown origin

- Chronic diarrhoea

Exclusion criteria:

- Patients age below 18 years

- Patients presenting with contraindications to video capsule endoscopy which are already known gastrointestinal stenoses, already known gastrointestinal adhesions, already known diverticula of the small bowel, already known severe or diabetes induced intestinal hypomotility

- Refusal to participate in the study

Methods

Our investigation will be performed at the Medical University of Vienna, department of medicine III, clinical division of gastroenterology and hepatology. Patient recruitment will start on the 1st of January 2010. The study will last for six month. The number of patients included within this period will be around 50, based on the current amount of VCE examinations performed at our department.

All patients who fulfil the listed inclusion criteria, will receive the patient information form of this study together with the routine informed consent form of VCE. Potentially occurring questions about the course of the examination, data acquisition and processing in context of the study will be answered by medical professionals.

As routine preparation for VCE, patients will receive 2 litres of washout solution on the previous day of their examination. At the day of the procedure fasting is required. The patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later - to our knowledge the first capsule will have already passed the gastro-duodenal transit at this time. The two capsules used in our investigation are the already mentioned MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list. After both capsules have been swallowed, fasting has to be continued for four hours to prevent image interference of VCE.

Risk/Benefit Assessment

The safety of both products used within our investigation was already proved in former clinical trials [7, 8]. For the patients enrolled in our study the potentially higher risk of complications will be made up for the expected increase of diagnostic yield that will be implicated by the evaluation of two different bowel videos. The only notable discomfort for patients participating in our investigation will be caused by the rather high amount of adhesive electrodes necessary for both capsules. There should not be any interference of the two video signals as already shown in former investigations [6,9].


Recruitment information / eligibility

Status Completed
Enrollment 50
Est. completion date October 2011
Est. primary completion date April 2011
Accepts healthy volunteers No
Gender Both
Age group 18 Years to 85 Years
Eligibility Inclusion Criteria:

Patients transferred to our unit to undergo video capsule endoscopy because of

- Obscure digestive bleeding (ODB)

- Chronic anaemia of unknown origin

- Chronic diarrhoea

Exclusion Criteria:

- Patients age below 18 years

- Patients presenting with contraindications to video capsule endoscopy which are already known gastrointestinal stenoses, already known gastrointestinal adhesions, already known diverticula of the small bowel, already known severe or diabetes induced intestinal hypomotility

- Refusal to participate in the study

Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Single Group Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Diagnostic


Related Conditions & MeSH terms


Intervention

Procedure:
Video capsule endoscopy (VCE)
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.
Device:
MiroCam
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.
Enteropro EndoCapsule
In the context of video capsule endoscopy the patient will swallow the first capsule after successful mounting of adhesive electrodes and registering tool of both capsule products. The second capsule will be swallowed two hours later. The two capsules used in our investigation are the MiroCam® (product of IntroMedic®, Seoul, Korea) and the Enteropro EndoCapsule® (product of Olympus®, Tokyo, Japan). To reduce bias made up by the sequence of the capsules used, we will randomize the capsule positions at each examination, following a computer generated list.

Locations

Country Name City State
Austria Medical University of Vienna, Department of Medicine III., Clinical Division of Gastroenterology and Hepatology Vienna

Sponsors (1)

Lead Sponsor Collaborator
Medical University of Vienna

Country where clinical trial is conducted

Austria, 

References & Publications (9)

Bang S, Park JY, Jeong S, Kim YH, Shim HB, Kim TS, Lee DH, Song SY. First clinical trial of the "MiRo" capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest Endosc. 2009 Feb;69(2):253-9. doi: 10.1016/j.gie.2008.04.033. Epub 2008 Jul 21. — View Citation

Cave DR, Fleischer DE, Leighton JA, Faigel DO, Heigh RI, Sharma VK, Gostout CJ, Rajan E, Mergener K, Foley A, Lee M, Bhattacharya K. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest Endosc. 2008 Sep;68(3):487-94. doi: 10.1016/j.gie.2007.12.037. Epub 2008 Apr 14. — View Citation

Gheorghe C, Iacob R, Bancila I. Olympus capsule endoscopy for small bowel examination. J Gastrointestin Liver Dis. 2007 Sep;16(3):309-13. Review. — View Citation

He Man Kim. Sequential capsule endoscopy of two different capsule endoscopes, MiroCam and Pillcam SB1, without interference: a pilot study. UEGW Oct 21, 2008.

Kalantzis C, Triantafyllou K, Papadopoulos AA, Alexandrakis G, Rokkas T, Kalantzis N, Ladas SD. Effect of three bowel preparations on video-capsule endoscopy gastric and small-bowel transit time and completeness of the examination. Scand J Gastroenterol. 2007 Sep;42(9):1120-6. — View Citation

Muñoz-Navas M. Capsule endoscopy. World J Gastroenterol. 2009 Apr 7;15(13):1584-6. Review. — View Citation

Nakamura T, Terano A. Capsule endoscopy: past, present, and future. J Gastroenterol. 2008;43(2):93-9. doi: 10.1007/s00535-007-2153-6. Epub 2008 Feb 29. Review. — View Citation

Sanchez-Yague A. Risk factors for incomplete small-bowel capsule endoscopy: should capsule retention be considered independently? Gastrointest Endosc. 2009 Oct;70(4):820; author reply 820. doi: 10.1016/j.gie.2009.02.018. — View Citation

Westerhof J, Weersma RK, Koornstra JJ. Risk factors for incomplete small-bowel capsule endoscopy. Gastrointest Endosc. 2009 Jan;69(1):74-80. doi: 10.1016/j.gie.2008.04.034. Epub 2008 Aug 8. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Total video length The primary endpoint will be the total video length registered as well as the rate of successful ileocoecal transitions during ongoing video registration. 6 months No
Secondary Diagnostic yield The secondary end point will be the number of pathologies detected by each capsule. 6 months No
See also
  Status Clinical Trial Phase
Terminated NCT00801931 - Double Cord Blood Transplant for Patients With Malignant and Non-malignant Disorders Phase 1/Phase 2
Completed NCT02948283 - Metformin Hydrochloride and Ritonavir in Treating Patients With Relapsed or Refractory Multiple Myeloma or Chronic Lymphocytic Leukemia Phase 1
Completed NCT03341338 - Genes-in-Action - Hepcidin Regulation of Iron Supplementation
Completed NCT00060398 - Epoetin Alfa With or Without Dexamethasone in Treating Fatigue and Anemia in Patients With Hormone-Refractory Prostate Cancer Phase 3
Recruiting NCT05384691 - Efficacy of Luspatercept in ESA-naive LR-MDS Patients With or Without Ring Sideroblasts Who do Not Require Transfusions Phase 2
Not yet recruiting NCT06309641 - Methemoglobinemia Following Intravenous Iron Treatment
Completed NCT02912494 - A Phase III Study of JR-131 in Renal Anemia Patients With Chronic Kidney Disease (CKD) Phase 3
Completed NCT02888171 - Impact of Ferric Citrate vs Ferrous Sulfate on Iron Parameters and Hemoglobin in Individuals With CKD and Iron Deficiency N/A
Completed NCT03822884 - Pharmacokinetic/Pharmacodynamic Study of 3 Subcutaneous Single Dose Epoetin Alfa Formulations in Healthy Volunteers Phase 1
Completed NCT02930850 - Spot-Check Noninvasive Hemoglobin (SpHb) Clinical Validation N/A
Completed NCT02912533 - A Long-term Study of JR-131 in Renal Anemia Patients With Chronic Kidney Disease (CKD) Phase 3
Completed NCT02384122 - Efficacy of Octreotide on Blood and Iron Requirements in Patients With Anemia Due to Angiodysplasias Phase 3
Completed NCT02603250 - Evaluation of Hemoglobin Measurement Tools for Child Anemia Screening in Rwanda N/A
Completed NCT02176759 - Iron Absorption From Rice Fortified With Ferric Pyrophosphate N/A
Completed NCT02310113 - Transfusion and Skeletal Muscle Tissue Oxygenation N/A
Completed NCT01922479 - Pilot Study of Ferric Carboxymaltose to Treat Iron Deficiency in Asians With Heart Failure Phase 4
Withdrawn NCT01934842 - A Study to Compare Analyte Levels in Blood Collected Using an Investigational Collection Device With a Commercial Predicate N/A
Completed NCT01693029 - Study to Compare Safety and Efficacy of HX575 Epoetin Alfa and US-licensed Epoetin Alfa Phase 3
Completed NCT01432717 - Study of ACE-536 in Healthy Postmenopausal Women Phase 1
Terminated NCT01535781 - Study of the Effect of Tranexamic Acid Administered to Patients With Hip Fractures. Can Blood Loss be Reduced? N/A