Acute Respiratory Distress Syndrome Clinical Trial
Official title:
Assessment of the Determinants of the Thoracic Fluid Content Measured by the Bioimpedance-based Starling System in Critically Ill Patients
The Starling system is a completely non-invasive hemodynamic monitoring technique. It is able to measure the thoracic fluid content (TFC). The TFC is supposed to reflect the total content of fluid in the thorax. Thus, TFC may include two of the variables that are commonly used for hemodynamic monitoring: the extravascular lung water (EVLW), and the global end-diastolic volume (GEDV). However, whether the TFC actually reflects GEDV and EVLW has not been clearly established. The objective of the study is to establish the determinants of TFC among hemodynamic variables including EVLW and GEDV.
The Starling system is a completely non-invasive hemodynamic monitoring technique. It measures cardiac output through bioreactance. It also measures the mean transthoracic electric impedance (Z0) from which the thoracic fluid content (TFC) can be derived. The TFC is the only other variable that is provided by the system besides cardiac output and that is not inferred from it. The TFC is supposed to reflect the total content of fluid in the thorax and may include two of the variables that are commonly used for hemodynamic monitoring: the extravascular lung water (EVLW), which is the volume of lung edema, and the global end-diastolic volume (GEDV), which is a static index of cardiac preload. Cardiac preload is an important physiological variable; a prerequisite for TFC as a reflect cardiac preload would be that its changes are tightly linked to the changes in well-established markers of cardiac preload, as the GEDV measured by transpulmonary thermodilution, or the central venous pressure (CVP). Nevertheless, this has never been demonstrated. In addition, TFC includes the volume of EVLW, which is the volume of fluid contend in the lungs outside the pulmonary vessels. Nevertheless, the degree to which TFC is influenced by absolute values and changes in EVLW has never been established. The objective of the study is to establish the determinants of TFC among well-known hemodynamic variables including EVLW and GEDV, as well the value of TFC as a marker of cardiac preload and lung water. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04384445 -
Zofin (Organicell Flow) for Patients With COVID-19
|
Phase 1/Phase 2 | |
Recruiting |
NCT05535543 -
Change in the Phase III Slope of the Volumetric Capnography by Prone Positioning in Acute Respiratory Distress Syndrome
|
||
Completed |
NCT04695392 -
Restore Resilience in Critically Ill Children
|
N/A | |
Terminated |
NCT04972318 -
Two Different Ventilatory Strategies in Acute Respiratory Distress Syndrome Due to Community-acquired Pneumonia
|
N/A | |
Completed |
NCT04534569 -
Expert Panel Statement for the Respiratory Management of COVID-19 Related Acute Respiratory Failure (C-ARF)
|
||
Completed |
NCT04078984 -
Driving Pressure as a Predictor of Mechanical Ventilation Weaning Time on Post-ARDS Patients in Pressure Support Ventilation.
|
||
Completed |
NCT04451291 -
Study of Decidual Stromal Cells to Treat COVID-19 Respiratory Failure
|
N/A | |
Not yet recruiting |
NCT06254313 -
The Role of Cxcr4Hi neutrOPhils in InflueNza
|
||
Not yet recruiting |
NCT04798716 -
The Use of Exosomes for the Treatment of Acute Respiratory Distress Syndrome or Novel Coronavirus Pneumonia Caused by COVID-19
|
Phase 1/Phase 2 | |
Withdrawn |
NCT04909879 -
Study of Allogeneic Adipose-Derived Mesenchymal Stem Cells for Non-COVID-19 Acute Respiratory Distress Syndrome
|
Phase 2 | |
Not yet recruiting |
NCT02881385 -
Effects on Respiratory Patterns and Patient-ventilator Synchrony Using Pressure Support Ventilation
|
N/A | |
Terminated |
NCT02867228 -
Noninvasive Estimation of Work of Breathing
|
N/A | |
Completed |
NCT02545621 -
A Role for RAGE/TXNIP/Inflammasome Axis in Alveolar Macrophage Activation During ARDS (RIAMA): a Proof-of-concept Clinical Study
|
||
Withdrawn |
NCT02253667 -
Palliative Use of High-flow Oxygen Nasal Cannula in End-of-life Lung Disease Patients
|
N/A | |
Completed |
NCT02232841 -
Electrical Impedance Imaging of Patients on Mechanical Ventilation
|
N/A | |
Completed |
NCT02889770 -
Dead Space Monitoring With Volumetric Capnography in ARDS Patients
|
N/A | |
Completed |
NCT01504893 -
Very Low Tidal Volume vs Conventional Ventilatory Strategy for One-lung Ventilation in Thoracic Anesthesia
|
N/A | |
Withdrawn |
NCT01927237 -
Pulmonary Vascular Effects of Respiratory Rate & Carbon Dioxide
|
N/A | |
Completed |
NCT01680783 -
Non-Invasive Ventilation Via a Helmet Device for Patients Respiratory Failure
|
N/A | |
Completed |
NCT02814994 -
Respiratory System Compliance Guided VT in Moderate to Severe ARDS Patients
|
N/A |