Clinical Trials Logo

Tachycardia clinical trials

View clinical trials related to Tachycardia.

Filter by:

NCT ID: NCT00800384 Completed - Clinical trials for Ventricular Tachycardia

Shockless Implant Evaluation

SIMPLE
Start date: January 2009
Phase: N/A
Study type: Interventional

This trial will assess the safety of defibrillator testing and the influence of defibrillation testing on the efficacy of clinical shocks. The trial will test the hypothesis that implantable cardioverter defibrillator (ICD) implantation without defibrillation testing (DT) is non-inferior to implantation with testing against the composite endpoint of ineffective first appropriate clinical shock or arrhythmic death. It will also test the hypothesis, that defibrillation testing increases the peri-operative (30 days) complication rate of ICD implantation.

NCT ID: NCT00787800 Completed - Atrial Fibrillation Clinical Trials

The Use of Dual Chamber ICD With Special Programmed Features to Lower the Risk of Inappropriate Shock

RAPTURE
Start date: November 2008
Phase: Phase 4
Study type: Interventional

The RAPTURE Study will determine whether dual chamber defibrillators with atrial prevention and termination therapies, minimized ventricular pacing, and remote monitoring will reduce the rate of inappropriate shocks and improve quality of life compared to optimally programmed back-up pacing only single chamber ICDs when used for primary prevention of sudden cardiac death

NCT ID: NCT00776087 Terminated - Clinical trials for Ventricular Fibrillation

European Health Economic Trial on Home Monitoring in ICD and CRT-D Patients (EuroEco)

EuroEco
Start date: October 17, 2008
Phase: N/A
Study type: Interventional

BIOTRONIK Home Monitoring (HM) service enables the doctors to safely follow up (FU) their ICD and CRT-D patients in a remote fashion, with fewer in-clinic consultations. This may result in a more efficient FU and cost-savings for the health care payer. The EuroEco study: 1. Outlines a new HM-based FU model for the ICD and CRT-D patients that combines in-clinic consultations and regular check ups of the patient/ICD/CRT-D data received through the HM service. 2. Compares the direct costs for physicians and clinics for the HM-based FU of ICD and CRT-D patients versus the traditional FU. 3. Compares the indicators of patients' safety between the two FU models.

NCT ID: NCT00770484 Completed - Clinical trials for Postural Tachycardia Syndrome

Effect of Exercise in OI

Start date: November 2008
Phase: N/A
Study type: Interventional

The main limitation patients with orthostatic intolerance (OI, or postural tachycardia syndrome, POTS) have to exercise is related to their increase in heart rate when standing. Main pharmacological treatment today is aimed at reducing heart rate with the use of betablockers (propanolol), this theoretically could also improve their exercise capacity; if their heart rate do not increase as much with the medication, they could exercise more. In addition, it has been suggested that in healthy volunteers subjected to head down tilt for 2 weeks (situation that produces a "simulated" transient POTS-like state) a single bout of intense exercise can improve orthostatic tolerance the day after exercising. The mechanisms involved in such response are not that clear but could be an increase in plasma volume already diminished in POTS patients. It seems likely that the same could be true for POTS patients. The purpose of the present study are to pharmacologically improve the amount of exercise POTS patients can perform by reducing their baseline heart rate (specific aim 1) and to evaluate next day heart responses to an acute bout of intense exercise. Therefore, the specific aims of this study are: 1. To test the hypothesis that lowering heart rate response with propanolol will result in an increase in exercise capacity. 2. To test the hypothesis that a single bout of exercise will result in an improvement in orthostatic tolerance the day after exercising.

NCT ID: NCT00749671 Terminated - Clinical trials for Tachycardia, Ventricular

Bispectral Index Monitoring During Testing in the Electrophysiology Lab

Start date: October 2007
Phase: N/A
Study type: Interventional

BACKGROUND Physician-guided moderate sedation, administered by a Registered Nurse has been the standard of practice for patients undergoing a wide range of electrophysiology procedures during the past decade. Currently a subjective sedation assessment tool is the standard of practice within the Electrophysiology Lab (EP Lab). Bispectral Index monitoring (BIS) is an objective measure of the depth of sedation presently employed at Baystate Medical Center in the Intensive Care Unit and within the department of anesthesia. AIM The aim of this research study is to assess the utility of BIS monitoring in measuring the depth of sedation in patients undergoing defibrillation threshold testing (DFT). Our primary endpoint is: A change in OAAS scores of one point at the 30 minute data collection time period. Our secondary endpoints are: Lack of explicit recall of DFT testing and measurement of perioperative level of comfort. STUDY DESIGN AND SCOPE The population to be studied is those patients receiving a primary ICD implant or an ICD battery change with defibrillation threshold testing (DFT). All patients who have consented for ICD placement and DFT testing with moderate sedation will be invited to participate in this research study. Patients who are not candidates for DFT testing, as is determined by the EP physician, will be excluded from the study. Demographic data including: age, gender, BMI, current medications and history of sleep apnea will be collected. Data detailing the amount of drug administered during the procedure and any use of reversal agents, will be retrieved from the medical record. The study will be conducted within the Electrophysiology lab at Baystate Medical Center. An enrollment of 60 subjects is expected to be completed within 6 months. 30 patients will originate from the outpatient population and 30 from the inpatient. Follow up assessments using the OAAS scale will be completed at 30 min, 1 hour and 4 hours post procedure. Also, perioperative comfort and recall of DFT testing will be assessed at the 4 hour mark.

NCT ID: NCT00748228 Terminated - Clinical trials for Postural Tachycardia Syndrome

Dopamine in Orthostatic Tolerance

Start date: November 2004
Phase: N/A
Study type: Interventional

One goal of this study is to determine whether people with different amounts of dopamine-beta-hydroxylase (DBH) have different responses to events that affect blood pressure and heart rate. We will also study whether increasing dietary salt improves symptoms during upright posture. Finally, we will examine whether the dietary sodium level influences serum DBH activity and whether DBH level influences the response to sodium. DBH levels and the function of the sympathetic or involuntary nervous system will be assessed in normal volunteers and in patients with postural tachycardia syndrome (POTS).

NCT ID: NCT00746564 Completed - Syncope Clinical Trials

Study of New Implantable Loop Recorder

Start date: September 2008
Phase: N/A
Study type: Interventional

The goal of this IDE clinical study is to evaluate the quality of the cardiac signal recordings obtained by the St. Jude Medical (SJM) Confirm Implantable Cardiac Monitor (device).

NCT ID: NCT00745745 Completed - Clinical trials for Ventricular Tachycardia

Septal Positioning of Ventricular Implanted Cardioverter Defibrillator (ICD) Leads

SPICE
Start date: August 2008
Phase: N/A
Study type: Interventional

This clinical trial is a multi center, prospective, randomized, parallel study designed to compare septal to apical ICD lead placement.

NCT ID: NCT00730548 Completed - Heart Failure Clinical Trials

Compare Remote Patient Management and Standard Care in CRT-D and ICD-patients to Assess the Effect on Heart Failure

ConnectOptiVol
Start date: November 2007
Phase: N/A
Study type: Interventional

This pilot study is to prospectively evaluate the benefit of clinicians being able to access ICD device information in a timelier manner and treat fluid overload with a pre-defined pattern using the Medtronic OptiVol, Medtronic CareAlerts and Medtronic CareLink in Conexus-enabled devices (remote arm) as compared to the same devices without Medtronic OptiVol, Medtronic CareAlerts and Medtronic CareLink available to the treating physician (standard arm).

NCT ID: NCT00729703 Completed - Tachycardia Clinical Trials

Optimal Anti-tachycardia Therapy in Implantable Cardioverter-defibrillator (ICD) Patients Without Pacing Indications

OPTION
Start date: June 2006
Phase: Phase 4
Study type: Interventional

This study evaluates the impact of a new pacing mode avoiding unnecessary ventricular stimulation in combination with advanced dual chamber detection with slow VT management on the clinical outcome for hospitalization and mortality and inadequate therapy in medically stable, ICD-indicated patients with impaired left ventricular function (LVEF ≤ 40%) who do not have pacing indications and no indication for Cardiac Resynchronization Therapy (CRT). It compares a new pacing mode avoiding ventricular stimulation when not needed combined with dual chamber detection with a pure ventricular back up pacing and single chamber detection criteria with pure ventricular back up pacing. Therapies are compared in a prospective, randomized, single-blinded, parallel trial with a 24-month randomized treatment period. Randomization follows a 1:1 ratio. ICD therapy is enabled for all patients throughout the study. All patients receive optimal drug therapy for arrhythmia and heart failure treatment.