View clinical trials related to Tachycardia.
Filter by:The SENSE-AF study aims to determine the performance of the OptiSense lead in sensing fine episodes of Atrial Tachyarrhythmia/Atrial Fibrillation (AT/AF) and rejecting Far-Field R Wave (FFRW). The performance of the lead will be measured as a difference in device-determined time in AT/AF and surface-ECG determined time in AT/AF. This measurement will be compared to the control group which will be randomized to receive SJM's Tendrilâ„¢ RA leads.
The study compares three treatment modalities in a human model of Postural orthostatic tachycardia syndrome (POTS): beta-blockers, I(f)-blockers, and placebo.
Patients with implantable cardioverter defibrillators (ICDs) should undergo regular device follow-ups every 3 months, to verify proper ICD function. However, many follow-ups are uneventful, revealing no relevant changes related to the implanted device and in the patient's diagnostic and therapeutic status. For time and economic reasons, longer follow-up intervals are frequently used although they are not according to recommendations. This may increase the delay in detection of relevant changes in the disease and in deviations from optimal ICD therapy in the individual patients. In the newest ICDs, the essential parameters reflecting safety and appropriateness of ICD therapy (threshold, impedance, intracardiac electrogram, etc.) are transmitted via Home Monitoring on a daily basis, to an internet platform accessible by the attending physician. In the present study, the investigators evaluate safety and efficacy of 12-month follow-up intervals in ICDs with Home Monitoring capability, as compared with conventional 3-month follow-up scheme.
Primary objective is to evaluate the safety and performance of the implanted Subcutaneous implantable cardioverter defibrillator (S-ICD) system. A maximum of 10 subjects were to be enrolled and followed for one month to collect data on the safety, efficacy, and performance of the implanted S-ICD system. Additionally, patient comfort will be assessed as will cosmetic outcome.
This is a prospective, non-randomized, multi-center clinical case series evaluating the outcomes of the magnetic navigation system in ventricular tachycardia (VT) cases. Subjects will be evaluated acutely and will be followed clinically at 1, 6 and 12 months post-treatment.
In this study, we will compare the quality of life in veterans having ICD who attend the ICD support groups to those who do not. We ask them to answer a set of quality of life questionnaires at baseline and then at 3,6,9 and 12 month visits. These questionnaires would be analyzed to assess if attending support groups made a difference. These results will be compared to a similar study done at Emory University on non veterans.
The purpose of the Advisa IPG clinical study is to evaluate the overall system safety and clinical performance of the Advisa DR Implantable Pulse Generator (IPG).
This prospective, randomized, single blind, multi-centre study will examine the effect of the right ventricular (RV) lead location in patients implanted with a cardiac resynchronization defibrillator. 1. Purpose : To compare the effect of RV mid-septal (RVS) versus RV apical (RVA) lead location on left ventricular reverse remodeling in patients indicated for cardiac resynchronization therapy device (CRT-D) over a period of 6 months and to evaluate the clinical outcome of the RVS versus RVA pacing, over a period of 12 months. 2. Objectives: The primary objective is to demonstrate that there is no difference between the two groups (RVA vs. RVS) in the change of left ventricular end systolic volume (LVESV), between baseline and 6 months. The secondary objectives are to evaluate the percentage of "echo-responders" plus additional clinical and safety outcomes. This prospective, randomized, multi-centre, single-blind with 2 parallel arms, non-inferiority study will be conducted in approximately 25 study centres in Europe. The patients will be randomized in a 1:1 ratio. A maximum of 416 patients will be enrolled in this study. All eligible patients will be followed through baseline, randomisation, pre discharge, 1, 6 and 12 months post-implant. Enrolment is expected to be completed in 18 months. The total duration of the study is expected to be approximately 30 months.
The purpose of this observational study is to collect data regarding the population of patients implanted with St. Jude Medical ICD.
The chronic success rate, defined as freedom from any atrial tachyarrhythmias will increase from 35% to 60% by ablation of complex fragmented atrial electrograms potentials in addition to pulmonary vein isolation (PVI) as compared to PVI alone in patients with long-standing persistent AF.