Clinical Trials Logo

Clinical Trial Summary

Current international guidelines recommend a three-month blanking period after pulmonary vein isolation (PVI) for atrial fibrillation (AF). Early recurrence of atrial tachyarrhythmia (ERAT; comprising of AF, left atrial tachycardia and atrial flutter) is common, occurring in up to 65% of patients, but in the first month is generally thought not to predict long-term AF recurrence, and re-intervention is not recommended. Suggested causes for ERAT include inflammation and arrhythmogenic structural changes caused by ablation lesions. Early, purely inflammatory ERAT would not lead to late AF recurrence as pulmonary vein reconnection is established as the main factor associated with long-term recurrence in paroxysmal AF. Previous studies have shown ERAT in the second to third month (rather than first month) to be a stronger predictor of late AF recurrence, due to presumed reduction in the contribution of the acute inflammatory response after this. Biochemical data have shown that the post-ablation inflammatory phase is usually limited to the first month after both radiofrequency (RF) and cryoballoon (CB) ablation, though inflammatory markers have been shown to be less elevated following CB PVI. Histologically, lesions formed by the two modalities differ significantly. RF lesions are characterised by irregular boundaries and significant disruption to the endothelium, exposing the sub-endothelial layer and resulting in significant and sustained platelet activation, changes which can last for many months. CB lesions on the other hand, are observed as well demarcated and homogenous within one week, with reduced thrombogenicity, which may lead to reduced inflammation. ERAT following CB ablation cannot be accurately predicted by inflammatory response and it is postulated that endothelial function may play a role in the development of ERAT in such patients. Some studies have shown reduced recurrence rate and re-hospitalisation amongst the CB population, including the FIRE and ICE trial, potentially resulting in a better patient experience with CB and the possibility of a shorter blanking period. Post-ablation inflammatory response is more predictive of ERAT following RF than CB PVI, and the latter is considered to be associated with less inflammation. There is however, a paucity of data evaluating endothelial function post-AF ablation and its correlation with ERAT or late recurrences of arrhythmia. Given that earlier re-intervention in patients with ERAT in the third month of the blanking period can result in greater outcomes with respect to late recurrence of AF, if it can be demonstrated that endothelial function testing in the first few months post-CB PVI can be predictive of later ERAT, then shortening the blanking period following CB PVI and performing repeat ablation to control troublesome later ERAT may reduce overall patient morbidity and re-hospitalisation. The purpose of this novel pilot study is to examine the relationship between the post-ablation inflammatory response, endothelial function and timing and frequency of ERAT for patients undergoing RF and CB PVI for paroxysmal or short-lived persistent (less than 6 months' duration) AF. If the initial data provides hypothesis generating information, the aim would be to perform the study on a larger basis with higher statistical power to determine whether early post-ablation endothelial function testing can predict recurrences and identify those suitable for earlier re-intervention.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT04269785
Study type Interventional
Source University of Manchester
Contact
Status Withdrawn
Phase N/A
Start date January 30, 2023
Completion date June 1, 2024

See also
  Status Clinical Trial Phase
Completed NCT05970120 - A Study of Intracardiac Ultrasound With the NUVISION NAV Ultrasound Catheter N/A
Recruiting NCT06014996 - Comparison of PFA vs. RFA in Patients With Symptomatic Paroxysmal Atrial Fibrillation. N/A
Completed NCT03624881 - Evaluation of VISITAG SURPOINT™ Module With External Processing Unit (EPU) Phase 4
Recruiting NCT05416086 - iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study N/A
Recruiting NCT05905835 - Treatment of PAF With the Synaptic System N/A
Active, not recruiting NCT05534581 - Comparison of Cryoballoon vs. Pulsed Field Ablation in Patients With Symptomatic Paroxysmal Atrial Fibrillation Phase 4
Active, not recruiting NCT05618340 - PFA for Paroxysmal Atrial Fibrillation N/A
Not yet recruiting NCT05974098 - Quality of Life Influencing Factors
Not yet recruiting NCT05024630 - Renal Denervation and pUlmonary Vein isolAtion With cryoabLation on Patients With Atrial Fibrillation and hypErtension N/A
Completed NCT02610803 - Paroxysmal Atrial Fibrillation in Patients With Acute Ischemic Stroke N/A
Completed NCT01913522 - Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation: Double Short vs. Standard Exposure Duration N/A
Withdrawn NCT01917981 - Testing the Accuracy of a Personal Heart Rhythm Monitor to Detect Prolonged Paroxysmal Atrial Fibrillation Phase 3
Terminated NCT01925885 - Focal Impulse and Rotor Modulation Ablation Trial for Treatment of Paroxysmal Atrial Fibrillation (FIRMAT-PAF) N/A
Completed NCT01693107 - Atrial Fibrillation Force Contact Ablation Study
Completed NCT01842529 - Botulinum Toxin Injection in Epicardial Fat Pads To Treat Atrial Fibrillation After Cardiac Surgery Phase 2
Completed NCT00971204 - Clinical Study of the CardioFocus Endoscopic Ablation System - Adaptive Contact (EAS-AC) for the Treatment of Symptomatic Atrial Fibrillation Phase 2
Completed NCT05043883 - Automated Assessment of PVI Using a Novel EP Recording System N/A
Recruiting NCT05172765 - Biomarker-Guided Optimization of Transcutaneous Vagal Stimulation for Atrial (BiG tVNS-AF) N/A
Recruiting NCT04529785 - Added Value of Vein of Marshal Ethanol Infusion Compared to Superior Vena Cava Isolation Alone in Patients Undergoing Repeat Ablation for Recurrent Paroxysmal Atrial Fibrillation Despite Durable PV Isolation N/A
Completed NCT04022954 - HD Mapping of Atrial Fibrillation in Asia Pacific