Parkinson Disease Clinical Trial
Official title:
Physiological Flow of Liquids Used in Dysphagia Management
Verified date | March 2021 |
Source | University Health Network, Toronto |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Observational |
For individuals with neurodegenerative conditions, such as Amyotrophic Lateral Sclerosis and Parkinson disease, swallowing impairment (i.e., dysphagia) is a common and serious symptom. Dysphagia places the affected individual at risk for secondary health consequences, including malnutrition and aspiration pneumonia, and negatively affects quality of life. Thickened liquids are commonly recommended for individuals with dysphagia, as they flow more slowly and reduce the risk of entry into the airway. However, there is limited understanding about how changes in liquid thickness modulate swallowing physiology in individuals with neurodegenerative conditions, and previous reports have shown that increased liquid thickness may contribute to the accumulation of residue in the throat. The purpose of this study is to explore swallowing physiology and function in individuals with neurodegenerative conditions, across five levels of liquid thickness (thin, slightly-thick, mildly-thick, moderately-thick, and extremely-thick), and to identify boundaries of "optimal liquid thickness", which maintain airway safety, without contributing to the accumulation of significant residue. Results from this study will help guide the clinical recommendations for thickened liquids in dysphagia management.
Status | Completed |
Enrollment | 40 |
Est. completion date | December 31, 2020 |
Est. primary completion date | December 31, 2020 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 90 Years |
Eligibility | Inclusion Criteria: - Adults (18+) with a confirmed diagnosis of Amyotrophic Lateral Sclerosis (ALS) or Parkinson's disease (PD) Exclusion Criteria: - People with a prior medical history of stroke - People with a prior medical history of acquired brain injury - People with a prior medical history of spinal or spinal cord injury - People with a prior medical history of cancer or surgery in the head and neck region - People who have had radiation to the head and neck for cancer - People who have a prior history of swallowing problems (e.g., from childhood, medical complication) - People with significant breathing difficulties (e.g., rely on mechanical ventilation) - People who rely solely on tube-feeding for all meals and nutrition - People who have Type I (insulin-dependent) Diabetes - Women who are pregnant - People who have allergies to barium, potato starch, corn starch, xanthan gum, milk products, latex or dental glue |
Country | Name | City | State |
---|---|---|---|
United States | University of Florida | Gainesville | Florida |
Lead Sponsor | Collaborator |
---|---|
University Health Network, Toronto | National Institute on Deafness and Other Communication Disorders (NIDCD), University of Florida |
United States,
Pearson WG Jr, Molfenter SM, Smith ZM, Steele CM. Image-based measurement of post-swallow residue: the normalized residue ratio scale. Dysphagia. 2013 Jun;28(2):167-77. doi: 10.1007/s00455-012-9426-9. Epub 2012 Oct 23. Review. — View Citation
Rosenbek JC, Robbins JA, Roecker EB, Coyle JL, Wood JL. A penetration-aspiration scale. Dysphagia. 1996 Spring;11(2):93-8. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Number of Participants With Residue of Concern (Observational) | Residue is material remaining behind in the pharynx after the swallow. We measured residue by tracing the area of barium visible on a lateral view x-ray (in pixels, using ImageJ software) and dividing that area by the squared length C2-C4 cervical spine. This cervical spine scalar provides a common anatomical reference that is a proxy for pharyngeal size, and enables the comparison of residue severity across different people with different neck length and pharynx size. Smaller values are considered better. The 75th percentile healthy reference values for this measure are 1.7% on thin liquids, 1.9% on slightly thick liquids, 2.2% on mildly thick liquids, 1.6% on moderately thick liquids and 1.5% on extremely thick liquids. Values above these thresholds are considered atypical and of clinical concern. We report the number of participants who display atypical total pharyngeal residue measures per consistency. | Single timeframe (baseline only) | |
Primary | Maximum Anterior Isometric Tongue Pressure | Tongue strength was measured using a tongue pressure measurement system called the Iowa Oral Performance Instrument (IOPI). A small disposable bulb filled with air was placed in the mouth, just behind the front teeth. Participants were asked to press the front of their tongue upwards against the bulb as hard as possible. This task was repeated 3 times. The maximum value obtained across 3 repetitions was recorded as "maximum anterior isometric pressure". Higher values represent greater tongue strength. We report group mean values and standard deviations for this measure. | Single timeframe (baseline only) | |
Primary | Regular Effort Saliva Swallow Tongue Pressure | Tongue strength was measured using a tongue pressure measurement system called the Iowa Oral Performance Instrument (IOPI). A small disposable bulb filled with air was placed in the mouth, just behind the front teeth. Participants were asked to swallow their saliva with the bulb in this position. This task was repeated 3 times. The mean value obtained across 3 repetitions was recorded as "regular effort saliva swallow tongue pressure". Higher values represent greater tongue strength. We report group mean values and standard deviations for this measure. | Single timeframe (baseline only) | |
Primary | Number of Participants With Unsafe Swallows (Observational) | Swallowing safety was measured using the 8-point Penetration-Aspiration Scale, an 8-point categorical scale which captures the depth to which any material enters the airway and whether or not the material is ejected. Levels 1 and 2 on the scale are considered safe, while levels > 2 are considered unsafe. Actual scale scores (1-8) were recorded and then converted to binary categorical scores (< 3 vs >/= 3). We report the frequency (count) of participants showing scores > 2 by bolus consistency. | Baseline (Single timepoint only) | |
Secondary | Maximum Posterior Isometric Tongue Pressure (Observational). | Tongue strength was measured using a tongue pressure measurement system called the Iowa Oral Performance Instrument (IOPI). A small disposable bulb filled with air was placed in the mouth, with the front margin of the sensor aligned with the first molar tooth. Participants were asked to press the back of their tongue upwards against the bulb as hard as possible. This task was repeated 3 times. The maximum value obtained across 3 repetitions was recorded as "maximum posterior isometric pressure". Higher values represent greater tongue strength. We report group mean values and standard deviations for this measure. There was no statistical analysis comparing group values for this parameter. | Single timeframe (baseline only) | |
Secondary | Number of Participants With Multiple Swallows Per Bolus (Observational) | The number of swallows needed to clear a single bolus will be counted. A single swallow is considered efficient, while 2+ swallows for one bolus is considered atypical. We will report the number of participants with > 1 swallow per bolus. | Single timeframe (baseline only) | |
Secondary | Number of Participants Displaying Prolonged Pharyngeal Bolus Transit (Observational) | The time interval from the first frame showing the bolus entering the pharynx (passing the shadow of the ramus of the mandible) until the first frame showing the bolus entering the upper esophageal sphincter was calculated (in milliseconds) for each bolus. The 75th percentile healthy reference values for this measure are 533 ms on thin liquids, 567 ms on slightly thick liquids, 701 ms on mildly thick liquids, 867 ms on moderately thick liquids and 1001 ms on extremely thick liquids. Pharyngeal transit durations above these values are considered prolonged and atypical. We will report the number of participants who present with atypical pharyngeal transit duration above these 75th percentile reference value thresholds per consistency. | Single timeframe (baseline only) |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05415774 -
Combined Deep Brain Stimulation in Parkinson's Disease
|
N/A | |
Recruiting |
NCT04691661 -
Safety, Tolerability, Pharmacokinetics and Efficacy Study of Radotinib in Parkinson's Disease
|
Phase 2 | |
Active, not recruiting |
NCT05754086 -
A Multidimensional Study on Articulation Deficits in Parkinsons Disease
|
||
Completed |
NCT04045925 -
Feasibility Study of the Taïso Practice in Parkinson's Disease
|
N/A | |
Recruiting |
NCT04194762 -
PARK-FIT. Treadmill vs Cycling in Parkinson´s Disease. Definition of the Most Effective Model in Gait Reeducation
|
N/A | |
Completed |
NCT02705755 -
TD-9855 Phase 2 in Neurogenic Orthostatic Hypotension (nOH)
|
Phase 2 | |
Terminated |
NCT03052712 -
Validation and Standardization of a Battery Evaluation of the Socio-emotional Functions in Various Neurological Pathologies
|
N/A | |
Recruiting |
NCT05830253 -
Free-living Monitoring of Parkinson's Disease Using Smart Objects
|
||
Recruiting |
NCT03272230 -
Assessment of Apathy in a Real-life Situation, With a Video and Sensors-based System
|
N/A | |
Recruiting |
NCT06139965 -
Validity and Reliability of the Turkish Version of the Comprehensive Coordination Scale in Parkinson's Patients
|
||
Completed |
NCT04580849 -
Telerehabilitation Using a Dance Intervention in People With Parkinson's Disease
|
N/A | |
Completed |
NCT03980418 -
Evaluation of a Semiconductor Camera for the DaTSCAN™ Exam
|
N/A | |
Completed |
NCT04477161 -
Effect of Ketone Esters in Parkinson's Disease
|
N/A | |
Completed |
NCT04942392 -
Digital Dance for People With Parkinson's Disease During the COVID-19 Pandemic
|
N/A | |
Terminated |
NCT03446833 -
LFP Beta aDBS Feasibility Study
|
N/A | |
Completed |
NCT03497884 -
Individualized Precise Localization of rTMS on Primary Motor Area
|
N/A | |
Completed |
NCT05538455 -
Investigating ProCare4Life Impact on Quality of Life of Elderly Subjects With Neurodegenerative Diseases
|
N/A | |
Recruiting |
NCT04997642 -
Parkinson's Disease and Movement Disorders Clinical Database
|
||
Completed |
NCT04117737 -
A Pilot Study of Virtual Reality and Antigravity Treadmill for Gait Improvement in Parkinson
|
N/A | |
Recruiting |
NCT03618901 -
Rock Steady Boxing vs. Sensory Attention Focused Exercise
|
N/A |