Clinical Trials Logo

Clinical Trial Summary

This is a 26-week randomized, free-living, open-label, two-arm, two-phase, crossover trial. Participants will receive two interventions at different phases, including the Android artificial pancreas system(AndroidAPS-rt-CGM) and sensor-augment pump(SAP), and use marketed rapid-acting insulin analogs (insulin Aspart, insulin Lispro, or insulin Glulisine) normally used in their usual clinical care. The safety and efficacy of AndroidAPS-rt-CGM and SAP in adult T1DM with suboptimal glycemic control will be compared to explore whether the use of AndroidAPS-rt-CGM in adult T1DM with suboptimal glycemic control will be associated with better glycemic control with no increased hypoglycemia.


Clinical Trial Description

All participants will be free to live during the study. Each intervention phase is 12 weeks, preceded by a 2-week training period and separated by a 2-week washout period. During the training period, eligible participants will be trained to use the study rt-CGM and insulin pump and randomly assigned 1:1 to two treatment sequences after the training period. In Sequence A, patients use AndroidAPS-rt-CGM for the first intervention period (phase 1) and SAP for the second intervention period (phase 2); in Sequence B, patients use SAP for Phase 1 and AndroidAPS-rt-CGM for Phase 2. Participants who enter sequences A and B will be trained to use the study devices running in automated insulin delivery(AID) mode on the first day of phase 1 and phase 2, respectively. AndroidAPS-rt-CGM consists of three components:1) AiDEX G7 continuous glucose monitoring (an rt-CGM);2) Equil® insulin patch pump;3) AndroidAPS algorithm implemented in Android smartphone. The participants will use the study patch pump and rt-CGM, but the AndroidAPS algorithm and advanced features will not be allowed during the SAP intervention period. During the washout period, participants will continue using the study insulin pump with their standard settings, but the study rt-CGM will be replaced by daily self-monitoring of fingerstick glucose. The primary endpoint is time in range (3.9-10.0 mmol/L) derived from CGM. The main secondary endpoints include the percentage of sensor glucose values below, within, and above the target range; mean sensor glucose value; measures of glycemic variability, and centralized HbA1c. Safety endpoints mainly include the frequency of hypoglycemia events, diabetic ketoacidosis, and other serious adverse events. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05726461
Study type Interventional
Source Third Affiliated Hospital, Sun Yat-Sen University
Contact Jinhua Yan, phD
Phone +8613929589959
Email yanjh79@163.com
Status Recruiting
Phase N/A
Start date February 11, 2023
Completion date September 30, 2024

See also
  Status Clinical Trial Phase
Completed NCT03743779 - Mastering Diabetes Pilot Study
Completed NCT03786978 - Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus N/A
Completed NCT01804803 - DIgital Assisted MONitoring for DiabeteS - I N/A
Completed NCT05039970 - A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program N/A
Completed NCT04507867 - Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III N/A
Completed NCT04068272 - Safety of Bosentan in Type II Diabetic Patients Phase 1
Completed NCT03243383 - Readmission Prevention Pilot Trial in Diabetes Patients N/A
Completed NCT03730480 - User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS) N/A
Recruiting NCT02690467 - Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm. N/A
Completed NCT02229383 - Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus Phase 3
Completed NCT05799976 - Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure N/A
Completed NCT06181721 - Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes N/A
Recruiting NCT04489043 - Exercise, Prediabetes and Diabetes After Renal Transplantation. N/A
Withdrawn NCT03319784 - Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients Phase 4
Completed NCT03542084 - Endocrinology Auto-Triggered e-Consults N/A
Completed NCT02229396 - Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo Phase 3
Recruiting NCT05544266 - Rare and Atypical Diabetes Network
Completed NCT01892319 - An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
Completed NCT05031000 - Blood Glucose Monitoring Systems: Discounter Versus Brand N/A
Recruiting NCT04039763 - RT-CGM in Young Adults at Risk of DKA N/A