Diabetes Mellitus Clinical Trial
Official title:
Studying the Effectiveness of Non-Invasive Glucose Sensors in Patients With Diabetes: The SENSOR Study
The overall goal for this pilot clinical trial is to explore the accuracy and acceptability of a non-invasive, wearable glucose sensor in patients living with DM. This study will compare needleless glucose sensor readings with glucometer measurements from patients with type 1 or type 2 diabetes (T1DM or T2DM), under varying conditions.
Self-monitoring of blood glucose (SMBG) can both facilitate and hinder adherence in patients
with diabetes mellitus (DM). Readings provide real-time information on hypoglycemic and
hyperglycemic excursions. These data are crucial to successfully managing this disease, as
SMBG can help guide decisions on titrating medications, and can potentially encourage patient
engagement. There are drawbacks. Piercing the skin to check glucose up to several times a day
can be uncomfortable and obtrusive for a patient with DM. SMBG offers only a snapshot of the
patient's glucose at the time of testing.
Continuous glucose monitoring (CGM) can reveal glucose trends. A subcutaneous sensor
transmits interstitial glucose readings approximately every five minutes. Yet, sensor
insertion requires a needle. Patients still must test SMBG about 4 times per day to calibrate
the CGM sensor. This modality is less accurate with low or rapidly rising glucose. CGM is
also not widely available, due to cost and insurance issues. A non-invasive glucose monitor,
the GlucoWatch, was discontinued due to problems with accuracy and tolerability.
Compounding these challenges is the surging number of individuals with DM. Every 19 seconds,
an American 20 years of age or older is diagnosed with DM. If current trends continue, 1 in 3
Americans could have DM by 2050.
There is thus an unmet need for a non-invasive glucose monitoring device. UCSD nanoengineers
developed a flexible, ultra-thin sensor adherent to the skin, similar to a temporary tattoo.
Preliminary data from seven individuals without DM demonstrated correlation between glucose
measurements from this sensor and a glucometer. Evaluating this sensor in patients with DM
will be critical: while hour-to-hour blood glucose fluctuates approximately 50% throughout
the day in those without DM, it may vary up to 10-fold in patients with DM. This study would
be the first to examine this sensor in individuals with DM. The investigators hypothesize
that compared with a glucometer, a tattoo sensor can accurately measure glucose in patients
with DM.
;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT03743779 -
Mastering Diabetes Pilot Study
|
||
| Completed |
NCT03786978 -
Pharmaceutical Care in the Reduction of Readmission Rates in Diabetes Melitus
|
N/A | |
| Completed |
NCT01804803 -
DIgital Assisted MONitoring for DiabeteS - I
|
N/A | |
| Completed |
NCT05039970 -
A Real-World Study of a Mobile Device-based Serious Health Game on Session Attendance in the National Diabetes Prevention Program
|
N/A | |
| Completed |
NCT04507867 -
Effect of a NSS to Reduce Complications in Patients With Covid-19 and Comorbidities in Stage III
|
N/A | |
| Completed |
NCT04068272 -
Safety of Bosentan in Type II Diabetic Patients
|
Phase 1 | |
| Completed |
NCT03243383 -
Readmission Prevention Pilot Trial in Diabetes Patients
|
N/A | |
| Completed |
NCT03730480 -
User Performance of the CONTOUR NEXT and CONTOUR TV3 Blood Glucose Monitoring System (BGMS)
|
N/A | |
| Recruiting |
NCT02690467 -
Efficacy, Safety and Acceptability of the New Pen Needle 34gx3,5mm.
|
N/A | |
| Completed |
NCT02229383 -
Phase III Study to Evaluate Safety and Efficacy of Added Exenatide Versus Placebo to Titrated Basal Insulin Glargine in Inadequately Controlled Patients With Type II Diabetes Mellitus
|
Phase 3 | |
| Completed |
NCT06181721 -
Evaluating Glucose Control Using a Next Generation Automated Insulin Delivery Algorithm in Patients With Type 1 and Type 2 Diabetes
|
N/A | |
| Completed |
NCT05799976 -
Text Message-Based Nudges Prior to Primary Care Visits to Increase Care Gap Closure
|
N/A | |
| Recruiting |
NCT04489043 -
Exercise, Prediabetes and Diabetes After Renal Transplantation.
|
N/A | |
| Withdrawn |
NCT03319784 -
Analysis for NSAID VS Corticosteroid Shoulder Injection in Diabetic Patients
|
Phase 4 | |
| Completed |
NCT03542084 -
Endocrinology Auto-Triggered e-Consults
|
N/A | |
| Completed |
NCT02229396 -
Phase 3 28-Week Study With 24-Week and 52-week Extension Phases to Evaluate Efficacy and Safety of Exenatide Once Weekly and Dapagliflozin Versus Exenatide and Dapagliflozin Matching Placebo
|
Phase 3 | |
| Recruiting |
NCT05544266 -
Rare and Atypical Diabetes Network
|
||
| Completed |
NCT01892319 -
An International Non-interventional Cohort Study to Evaluate the Safety of Treatment With Insulin Detemir in Pregnant Women With Diabetes Mellitus. Diabetes Pregnancy Registry
|
||
| Completed |
NCT05031000 -
Blood Glucose Monitoring Systems: Discounter Versus Brand
|
N/A | |
| Recruiting |
NCT04039763 -
RT-CGM in Young Adults at Risk of DKA
|
N/A |